Technetium-99m sestamibi parathyroid localization is accurate enough for scan-directed unilateral neck exploration

被引:96
|
作者
Borley, NR
Collins, REC
ODoherty, M
Coakley, A
机构
[1] KENT & CANTERBURY NHS TRUST,DEPT SURG,CANTERBURY CT1 3NG,KENT,ENGLAND
[2] KENT & CANTERBURY NHS TRUST,DEPT NUCL MED,CANTERBURY CT1 3NG,KENT,ENGLAND
关键词
D O I
10.1002/bjs.1800830734
中图分类号
R61 [外科手术学];
学科分类号
摘要
A retrospective study was conducted into technetium-99m sestamibi imaging of primary hyperparathyroidism to determine the accuracy of identification and localization of parathyroid pathology. Of 56 patients studied, 48 had full preoperative scan data, operative data and pathological results analysed. Overall scan accuracy was 96 per cent. For single gland pathology (adenoma) imaging had a sensitivity of 97 per cent, a specificity of 100 per cent and a positive predictive value of 100 per cent. For single gland disease the side was correctly identified in 100 per cent of cases and the site in 94 per cent, but the respective values were only 82 and 79 per cent for multiple gland pathology. Technetium-99m sestamibi imaging is highly sensitive and accurate for primary hyperparathyroidism, with sufficient positive predictive value and accuracy in single gland disease to allow scan-directed unilateral neck exploration.
引用
收藏
页码:989 / 991
页数:3
相关论文
共 50 条
  • [1] Parathyroid imaging with technetium-99m sestamibi
    Fujii, H
    Kubo, A
    BIOMEDICINE & PHARMACOTHERAPY, 2000, 54 : 12S - 16S
  • [2] Sestamibi scan-directed unilateral neck exploration for primary hyperparathyroidism due to a solitary adenoma
    Kumar, A
    Cozens, NJA
    Nash, JR
    EUROPEAN JOURNAL OF SURGICAL ONCOLOGY, 2000, 26 (08): : 785 - 788
  • [3] Differences between technetium-99m tetrofosmin and technetium-99m sestamibi in parathyroid scintigraphy
    Giordano, A
    Meduri, G
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (03) : 347 - 347
  • [4] Differences between technetium-99m tetrofosmin and technetium-99m sestamibi in parathyroid scintigraphy
    Alessandro Giordano
    Guido Meduri
    European Journal of Nuclear Medicine, 1997, 24 : 347 - 347
  • [5] Preoperative parathyroid gland localization with technetium-99m sestamibi in secondary hyperparathyroidism
    Pons, F
    Torregrosa, JV
    Vidal-Sicart, S
    Sabater, L
    Fuster, D
    Fernández-Cruz, L
    Herranz, R
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (12) : 1494 - 1498
  • [6] Preoperative parathyroid gland localization with technetium-99m sestamibi in secondary hyperparathyroidism
    Francesca Pons
    Josep-Vicens Torregrosa
    Sergi Vidal-Sicart
    Lluís Sabater
    David Fuster
    Laureano Fernández-Cruz
    Ramón Herranz
    European Journal of Nuclear Medicine, 1997, 24 : 1494 - 1498
  • [7] SCAN-DIRECTED UNILATERAL CERVICAL EXPLORATION FOR PARATHYROID ADENOMA - A LEGITIMATE APPROACH
    RUSSELL, CFJ
    LAIRD, JD
    FERGUSON, WR
    WORLD JOURNAL OF SURGERY, 1990, 14 (03) : 406 - 409
  • [8] Parathyroid localization with technetium-99m-sestamibi: A prospective evaluation
    McHenry, CR
    Lee, K
    Saadey, J
    Neuman, DR
    Esselstyn, CB
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 1996, 183 (01) : 25 - 30
  • [9] Prospective randomized study of scan-directed unilateral exploration versus bilateral cervical exploration for parathyroid adenoma
    Scoffield, J
    McAllister, S
    Laird, JD
    Russell, CFJ
    BRITISH JOURNAL OF SURGERY, 2001, 88 (09) : 1276 - 1276
  • [10] 99m-technetium sestamibi localized solitary parathyroid adenoma as an indication for limited unilateral surgical exploration
    Gupta, VK
    Yeh, KA
    Burke, GJ
    Wei, JP
    AMERICAN JOURNAL OF SURGERY, 1998, 176 (05): : 409 - 412