Technetium-99m sestamibi parathyroid localization is accurate enough for scan-directed unilateral neck exploration

被引:96
|
作者
Borley, NR
Collins, REC
ODoherty, M
Coakley, A
机构
[1] KENT & CANTERBURY NHS TRUST,DEPT SURG,CANTERBURY CT1 3NG,KENT,ENGLAND
[2] KENT & CANTERBURY NHS TRUST,DEPT NUCL MED,CANTERBURY CT1 3NG,KENT,ENGLAND
关键词
D O I
10.1002/bjs.1800830734
中图分类号
R61 [外科手术学];
学科分类号
摘要
A retrospective study was conducted into technetium-99m sestamibi imaging of primary hyperparathyroidism to determine the accuracy of identification and localization of parathyroid pathology. Of 56 patients studied, 48 had full preoperative scan data, operative data and pathological results analysed. Overall scan accuracy was 96 per cent. For single gland pathology (adenoma) imaging had a sensitivity of 97 per cent, a specificity of 100 per cent and a positive predictive value of 100 per cent. For single gland disease the side was correctly identified in 100 per cent of cases and the site in 94 per cent, but the respective values were only 82 and 79 per cent for multiple gland pathology. Technetium-99m sestamibi imaging is highly sensitive and accurate for primary hyperparathyroidism, with sufficient positive predictive value and accuracy in single gland disease to allow scan-directed unilateral neck exploration.
引用
收藏
页码:989 / 991
页数:3
相关论文
共 50 条
  • [41] TECHNETIUM TC 99M SESTAMIBI SCAN FOR LOCALIZING ABNORMAL PARATHYROID-GLANDS AFTER PREVIOUS NECK OPERATIONS - PRELIMINARY EXPERIENCE IN REOPERATIVE CASES
    MAJORS, JD
    BURKE, GJ
    MANSBERGER, AR
    WEI, JP
    SOUTHERN MEDICAL JOURNAL, 1995, 88 (03) : 327 - 330
  • [42] Single Photon Emission Computed Tomography (SPECT) Should be Routinely Performed for the Detection of Parathyroid Abnormalities Utilizing Technetium-99m Sestamibi Parathyroid Scintigraphy
    Thomas, Damita L.
    Bartel, Twyla
    Menda, Yusuf
    Howe, James
    Graham, Michael M.
    Juweid, Malik E.
    CLINICAL NUCLEAR MEDICINE, 2009, 34 (10) : 651 - 655
  • [43] Increased oxyphil cell ratio, parathyroid gland volume and weight correlate with the localisation of parathyroid adenoma on Technetium-99m MIBI scintigraphy scan
    Durmus, E. T.
    Kefeli, M.
    Baycelebi, D.
    Atmaca, A.
    Colak, R.
    Polat, C.
    Mete, O.
    VIRCHOWS ARCHIV, 2019, 475 : S224 - S224
  • [44] Indium-111 Pentreotide, technetium-99m Sestamibi and iodine-131 scan in metastases of differentiated thyroid carcinoma.
    Boni, G
    Ferdeghini, M
    Grosso, M
    Bellina, CR
    Manca, G
    Bianchi, R
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 1000 - 1000
  • [45] SUCCESSFUL LOCALIZATION OF PARATHYROID ADENOMATA BY TL-201 AND TECHNETIUM-99M SUBTRACTION SCINTIGRAPHY - DESCRIPTION OF AN IMPROVED TECHNIQUE
    FOGELMAN, I
    MCKILLOP, JH
    BESSENT, RG
    BOYLE, IT
    GRAY, HW
    GUNN, I
    HUTCHISON, JSF
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1984, 9 (12): : 545 - 547
  • [46] Improving-the yield of preoperative parathyroid localization: Technetium Tc 99m-sestamibi imaging after thyroid suppression
    Royal, RE
    Delpassand, ES
    Shapiro, SE
    Fritsche, HA
    Vassilopoulou-Sellin, R
    Sherman, SI
    Gagel, RF
    Evans, DB
    Lee, JE
    SURGERY, 2002, 132 (06) : 968 - 974
  • [47] In vivo detection of multidrug-resistant (MDR1) phenotype by technetium-99m sestamibi scan in untreated breast cancer patients
    DelVecchio, S
    Ciarmiello, A
    Potena, MI
    Carriero, MV
    Mainolfi, C
    Botti, G
    Thomas, R
    Cerra, M
    DAiuto, G
    Tsuruo, T
    Salvatore, M
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (02) : 150 - 159
  • [48] In vivo detection of multidrug-resistant (MDR1) phenotype by technetium-99m sestamibi scan in untreated breast cancer patients
    Silvana Del Vecchio
    Andrea Ciarmiello
    Maria I. Potena
    Maria V. Carriero
    Ciro Mainolfi
    Gerardo Botti
    Renato Thomas
    Maria Cerra
    Giuseppe D'Aiuto
    Takashi Tsuruo
    Marco Salvatore
    European Journal of Nuclear Medicine, 1997, 24 : 150 - 159
  • [49] In vivo detection of multidrug-resistant (MDR1) phenotype by technetium-99m sestamibi scan in untreated breast cancer patients
    Medicina Nucleare, Istituto di Scienze Radiologiche, Université degli Studi Federico II, Via Pansini, 5, Naples, Italy
    不详
    不详
    不详
    不详
    European Journal of Nuclear Medicine and Molecular Imaging, 1997, 24 (02): : 150 - 159
  • [50] The efficacy of technetium-99m-MIBI scan and intraoperative methylene blue staining for the localization of abnormal parathyroid glands
    Hiroyuki Takei
    Yuichi Iino
    Keigo Endo
    Jun Horiguchi
    Michio Maemura
    Yukio Koibuchi
    Yoshio Horii
    Takao Yokoe
    Tsunehiro Ishida
    Tetsunari Oyama
    Yasuo Morishita
    Surgery Today, 1999, 29 : 307 - 312