A retrospective study was conducted into technetium-99m sestamibi imaging of primary hyperparathyroidism to determine the accuracy of identification and localization of parathyroid pathology. Of 56 patients studied, 48 had full preoperative scan data, operative data and pathological results analysed. Overall scan accuracy was 96 per cent. For single gland pathology (adenoma) imaging had a sensitivity of 97 per cent, a specificity of 100 per cent and a positive predictive value of 100 per cent. For single gland disease the side was correctly identified in 100 per cent of cases and the site in 94 per cent, but the respective values were only 82 and 79 per cent for multiple gland pathology. Technetium-99m sestamibi imaging is highly sensitive and accurate for primary hyperparathyroidism, with sufficient positive predictive value and accuracy in single gland disease to allow scan-directed unilateral neck exploration.
引用
收藏
页码:989 / 991
页数:3
相关论文
共 50 条
  • [31] Parathyroid localization with high-resolution ultrasound and technetium Tc 99m sestamibi - Discussion
    Clark, OH
    Duh, QY
    Danto, LA
    Allo, M
    Wilson, SE
    Weigel
    ARCHIVES OF SURGERY, 1999, 134 (08) : 828 - 830
  • [32] Successful Removal of an Intrathyroidal Parathyroid Adenoma Located by Technetium Tc 99m Sestamibi Scan and Ultrasound
    Grisel, Jedidiah J.
    Al-Ghawi, Hayma
    Heubi, Christine H.
    Steward, David L.
    THYROID, 2009, 19 (04) : 423 - 425
  • [33] TECHNETIUM99M-SESTAMIBI SCANNING BEFORE INITIAL NECK EXPLORATION IN PATIENTS WITH PRIMARY HYPERPARATHYROIDISM
    BUGIS, SP
    BERNO, E
    RUSNAK, CH
    CHU, D
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 1995, 252 (03) : 149 - 152
  • [34] Early-phase technetium-99m sestamibi scintigraphy can improve preoperative localization in primary hyperparathyroidism
    Burke, Jocelyn F.
    Naraharisetty, Kalpana
    Schneider, David F.
    Sippel, Rebecca S.
    Chen, Herbert
    AMERICAN JOURNAL OF SURGERY, 2013, 205 (03): : 269 - 273
  • [35] In vivo uptake of technetium-99m-sestamibi by parathyroid glands in comparison to surrounding tissues of the neck - Discussion
    Roe, SM
    Waters, GS
    AMERICAN SURGEON, 1997, 63 (02) : 197 - 198
  • [36] Pre-operative localization and tissue uptake study in parathyroid imaging with technetium-99m-sestamibi
    Takami, H
    Oshima, M
    Sugawara, I
    Satake, S
    Ikeda, Y
    Nakamura, K
    Kubo, A
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1999, 65 (09): : 629 - 631
  • [37] USE OF TECHNETIUM TC-99M SESTAMIBI AND IODINE 123 RADIONUCLIDE SCAN FOR PREOPERATIVE LOCALIZATION OF ABNORMAL PARATHYROID-GLANDS IN PRIMARY HYPERPARATHYROIDISM
    HALVORSON, DJ
    BURKE, GJ
    MANSBERGER, AR
    WEI, JP
    SOUTHERN MEDICAL JOURNAL, 1994, 87 (03) : 336 - 339
  • [38] ANALYSIS OF SAVINGS IN OPERATIVE TIME FOR PRIMARY HYPERPARATHYROIDISM USING LOCALIZATION WITH TECHNETIUM 99M SESTAMIBI SCAN
    WEI, JP
    BURKE, GJ
    AMERICAN JOURNAL OF SURGERY, 1995, 170 (05): : 488 - 491
  • [39] Highly specific preoperative selection of solitary parathyroid adenoma cases in primary hyperparathyroidism by quantitative image analysis of the early-phase Technetium-99m sestamibi scan
    Kim, DaeHee
    Rhodes, Jeffrey A.
    Hashim, Jeffrey A.
    Rickabaugh, Lawrence
    Brams, David M.
    Pinkus, Edward
    Dou, Yamin
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2018, 62 (05) : 642 - 648
  • [40] Early-phase technetium-99m sestamibi scintigraphy can improve preoperative localization in primary hyperparathyroidism Discussion
    不详
    AMERICAN JOURNAL OF SURGERY, 2013, 205 (03): : 273 - 273