Quantitative structure-retention relationships applied to development of liquid chromatography gradient-elution method for the separation of sartans

被引:20
|
作者
Golubovic, Jelena [1 ]
Protic, Ana [1 ]
Otasevic, Biljana [1 ]
Zecevic, Mira [1 ]
机构
[1] Univ Belgrade, Fac Pharm, Dept Drug Anal, Vojvode Stepe 450,POB 146, Belgrade 11221, Serbia
关键词
II RECEPTOR ANTAGONISTS; SOLID-PHASE EXTRACTION; MASS-SPECTROMETRY; HUMAN PLASMA; HUMAN URINE; PREDICTION; HPLC; OPTIMIZATION; MODEL; DESCRIPTORS;
D O I
10.1016/j.talanta.2015.12.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
QSRR are mathematically derived relationships between the chromatographic parameters determined for a representative series of analytes in given separation systems and the molecular descriptors accounting for the structural differences among the investigated "analytes. Artificial neural network is a technique of data analysis, which sets out to emulate the human brain's way of working. The aim of the present work was to optimize separation of six angiotensin receptor antagonists, so-called sartans: losartan, valsartan, irbesartan, telmisartan, candesartan cilexetil and eprosartan in a gradient-elution HPLC method. For this purpose, ANN as a mathematical tool was used for establishing a QSRR model based on molecular descriptors of sartans and varied instrumental conditions. The optimized model can be further used for prediction of an external congener of sartans and analysis of the influence of the analyte structure, represented through molecular descriptors, on retention behaviour. Molecular descriptors included in modelling were electrostatic, geometrical and quantum-chemical descriptors: connolly solvent excluded volume non-1,4 van der Waals energy, octanol/water distribution coefficient, polarizability, number of proton-donor sites and number of proton-acceptor sites. Varied instrumental conditions were gradient time, buffer pH and buffer molarity. High prediction ability of the optimized network enabled complete separation of the analytes within the run time of 15.5 min under following conditions: gradient time of 12.5 min, buffer pH of 3.95 and buffer molarity of 25 mM. Applied methodology showed the potential to predict retention behaviour of an external analyte with the properties within the training space. Connolly solvent excluded volume, polarizability and number of proton-acceptor sites appeared to be most influential paramateres on retention behaviour of the sartans. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:190 / 197
页数:8
相关论文
共 50 条
  • [41] Localised quantitative structure-retention relationship modelling for rapid method development in reversed-phase high performance liquid chromatography
    Park, Soo Hyun
    De Pra, Mauro
    Haddad, Paul R.
    Grosse, Sylvia
    Pohl, Christopher A.
    Steiner, Frank
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1609
  • [42] Prediction of retention in gradient-elution normal-phase high-performance liquid chromatography with binary solvent gradients
    Jandera, P
    Kucerova, M
    JOURNAL OF CHROMATOGRAPHY A, 1997, 759 (1-2) : 13 - 25
  • [43] Immobilized artificial membrane chromatography:: Quantitative structure-retention relationships of structurally diverse drugs
    Luco, JM
    Salinas, AP
    Torriero, AAJ
    Vázquez, RN
    Raba, J
    Marchevsky, E
    JOURNAL OF CHEMICAL INFORMATION AND COMPUTER SCIENCES, 2003, 43 (06): : 2129 - 2136
  • [44] QUANTITATIVE STRUCTURE-RETENTION RELATIONSHIPS AND QUANTITATIVE STRUCTURE-ACTIVITY RELATIONSHIPS STUDY OF MACROLIDE ANTIBIOTICS ON MICELLAR THIN LAYER CHROMATOGRAPHY
    Ciura, Krzesimir
    Nowakowska, Joanna
    Kawczak, Piotr
    Greber, Katarzyna Ewa
    Markuszewski, Michal Jan
    ACTA POLONIAE PHARMACEUTICA, 2017, 74 (05): : 1365 - 1372
  • [45] Study on Quantitative Structure-Retention Relationships of Microemulsion Electrokinetic Chromatography Using Phospholipids as Surfactant
    Song Jing
    Zheng Yuan
    Huo Chang-Hong
    Liu Jian-Fang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (05) : 654 - 661
  • [46] Development of quantitative structure-retention relationships for gas chromatography using Ab initio molecular orbital calculations.
    Horvath, T
    Milletti, M
    Holmes, HS
    Trease, M
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 219 : U361 - U362
  • [47] Perspectives and recent advances in quantitative structure-retention relationships for high performance liquid chromatography. How far are we?
    Sagandykova, Gulyaim
    Buszewski, Boguslaw
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2021, 141
  • [48] Retention prediction of low molecular weight anions in ion chromatography based on quantitative structure-retention relationships applied to the linear solvent strength model
    Park, Soo Hyun
    Haddad, Paul R.
    Talebi, Mohammad
    Tyteca, Eva
    Amos, Ruth I. J.
    Szucs, Roman
    Dolan, John W.
    Pohl, Christopher A.
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1486 : 68 - 75
  • [49] Retention mechanism, isocratic and gradient-elution separation and characterization of (co)polymers in normal-phase and reversed-phase high-performance liquid chromatography
    Jandera, P
    Holcapek, M
    Kolárová, L
    JOURNAL OF CHROMATOGRAPHY A, 2000, 869 (1-2) : 65 - 84
  • [50] Quantitative structure-retention relationships of ionic liquid cations in characterization of stationary phases for HPLC
    Daghir-Wojtkowiak, Emilia
    Studzinska, Sylwia
    Buszewski, Boguslaw
    Kaliszan, Roman
    Markuszewski, Michal Jan
    ANALYTICAL METHODS, 2014, 6 (04) : 1189 - 1196