Quantitative structure-retention relationships applied to development of liquid chromatography gradient-elution method for the separation of sartans

被引:20
|
作者
Golubovic, Jelena [1 ]
Protic, Ana [1 ]
Otasevic, Biljana [1 ]
Zecevic, Mira [1 ]
机构
[1] Univ Belgrade, Fac Pharm, Dept Drug Anal, Vojvode Stepe 450,POB 146, Belgrade 11221, Serbia
关键词
II RECEPTOR ANTAGONISTS; SOLID-PHASE EXTRACTION; MASS-SPECTROMETRY; HUMAN PLASMA; HUMAN URINE; PREDICTION; HPLC; OPTIMIZATION; MODEL; DESCRIPTORS;
D O I
10.1016/j.talanta.2015.12.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
QSRR are mathematically derived relationships between the chromatographic parameters determined for a representative series of analytes in given separation systems and the molecular descriptors accounting for the structural differences among the investigated "analytes. Artificial neural network is a technique of data analysis, which sets out to emulate the human brain's way of working. The aim of the present work was to optimize separation of six angiotensin receptor antagonists, so-called sartans: losartan, valsartan, irbesartan, telmisartan, candesartan cilexetil and eprosartan in a gradient-elution HPLC method. For this purpose, ANN as a mathematical tool was used for establishing a QSRR model based on molecular descriptors of sartans and varied instrumental conditions. The optimized model can be further used for prediction of an external congener of sartans and analysis of the influence of the analyte structure, represented through molecular descriptors, on retention behaviour. Molecular descriptors included in modelling were electrostatic, geometrical and quantum-chemical descriptors: connolly solvent excluded volume non-1,4 van der Waals energy, octanol/water distribution coefficient, polarizability, number of proton-donor sites and number of proton-acceptor sites. Varied instrumental conditions were gradient time, buffer pH and buffer molarity. High prediction ability of the optimized network enabled complete separation of the analytes within the run time of 15.5 min under following conditions: gradient time of 12.5 min, buffer pH of 3.95 and buffer molarity of 25 mM. Applied methodology showed the potential to predict retention behaviour of an external analyte with the properties within the training space. Connolly solvent excluded volume, polarizability and number of proton-acceptor sites appeared to be most influential paramateres on retention behaviour of the sartans. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:190 / 197
页数:8
相关论文
共 50 条
  • [31] Review of research on quantitative structure-retention relationships in thin-layer chromatography
    Wang, QS
    Zhang, L
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1999, 22 (01) : 1 - 14
  • [32] Quantitative structure-retention relationships of flavonoids unraveled by immobilized artificial membrane chromatography
    Santoro, Adriana Leandra
    Carrilho, Emanuel
    Lancas, Fernando Mauro
    Montanari, Carlos Alberto
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2016, 88 : 147 - 157
  • [33] Determination of retention factors of aromatic compounds by gradient-elution reverse-phase high performance liquid chromatography
    Lee, JW
    Row, KH
    KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2002, 19 (06) : 978 - 985
  • [34] Determination of retention factors of aromatic compounds by gradient-elution reverse-phase high performance liquid chromatography
    Ju Weon Lee
    Kyung Ho Row
    Korean Journal of Chemical Engineering, 2002, 19 : 978 - 985
  • [35] Review of research on quantitative structure-retention relationships in thin-layer chromatography
    Wang, Q.S.
    Zhang, L.
    Journal of Liquid Chromatography and Related Technologies, 1999, 22 (01): : 1 - 14
  • [36] Retention prediction using quantitative structure-retention relationships combined with the hydrophobic subtraction model in reversed-phase liquid chromatography
    Wen, Yabin
    Amos, Ruth I. J.
    Talebi, Mohammad
    Szucs, Roman
    Dolan, John W.
    Pohl, Christopher A.
    Haddad, Paul R.
    ELECTROPHORESIS, 2019, 40 (18-19) : 2415 - 2419
  • [37] Quantitative structure-retention relationships in reversed-phase liquid chromatography using several stationary and mobile phases
    Vonk, EC
    Lewandowska, K
    Claessens, HA
    Kaliszan, R
    Cramers, CA
    JOURNAL OF SEPARATION SCIENCE, 2003, 26 (9-10) : 777 - 792
  • [38] Mechanism of separation on cholesterol-silica stationary phase for high-performance liquid chromatography as revealed by analysis of quantitative structure-retention relationships
    Al-Haj, MA
    Haber, P
    Kaliszan, R
    Buszewski, B
    Jezierska, M
    Chilmonzyk, Z
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (4-5) : 721 - 728
  • [39] Strategy for reduced calibration sets to develop quantitative structure-retention relationships in high-performance liquid chromatography
    Andries, Jan P. M.
    Claessens, Henk A.
    Heyden, Yvan Vander
    Buydens, Lutgarde M. C.
    ANALYTICA CHIMICA ACTA, 2009, 652 (1-2) : 180 - 188
  • [40] Modern Gas Chromatography, Column Liquid Chromatography, Planar Chromatography, and Bioanalytical Methods for the Analysis of Pesticides and Study of Quantitative Structure-Retention Relationships
    Tuzimski, Tomasz
    JOURNAL OF AOAC INTERNATIONAL, 2010, 93 (06) : 1679 - 1680