A new approach to characterising the etch rate ratio in CR-39 using a function of two variables

被引:0
|
作者
Dörschel, B [1 ]
Hermsdorf, D [1 ]
Kadner, K [1 ]
Starke, S [1 ]
机构
[1] Tech Univ Dresden, Dept Phys, Inst Radiat Protect Phys, D-01062 Dresden, Germany
关键词
light ions; track etch rate; etch rate ratio; restricted energy loss; Bragg curve; CR-39;
D O I
10.1016/S1350-4487(02)00057-4
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The formation of etched tracks in solid-state nuclear track detectors is usually described assuming an unequivocal correlation of the etch rate ratio with the energy loss of charged particles. For protons, deuterons and alpha particles this assumption could be verified within the scatter of the experimental data. Experimental studies with Li-7, B-11 and C-12 ions yielded, however, systematic deviations from the expected results. Analysing the complete experimental data set for CR-39, a dependence of the etch rate ratio was found not only on the particle's energy loss, but also on the depth within the detector where this energy loss occurs. Arranging the etch rate ratio as a function of both these variables all experimental results appear without inconsistencies. The etch rate ratio represented by a two-dimensional matrix can be used, then, for characterising the etch kinetics along the trajectories of charged particles of different kinds and initial energy. (C) 2002 Published by Elsevier Science Ltd.
引用
收藏
页码:293 / 299
页数:7
相关论文
共 50 条
  • [41] Dose-rate effects on the bulk etch-rate of CR-39 track detector exposed to low-LET radiations
    Yamauchi, T
    Taniguchi, T
    Oda, K
    Ikeda, T
    Honda, Y
    Tagawa, S
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 121 - 126
  • [42] Applicability of the multi-hit model to calculate the track etch rate in μm-scale in CR-39 detectors
    Awad, EM
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2003, 158 (07): : 539 - 550
  • [43] Direct determination of track etch rate and response of CR-39 to normal incidence high-energy heavy ions
    Awad, EM
    RADIATION MEASUREMENTS, 2001, 33 (06) : 855 - 858
  • [44] Bulk etch rate for PADC CR-39 at extended concentration range of NaOH mixed with ethanol and etchant viscosity study
    Awad, E. M.
    Hassan, Sameh
    Bebers, Eman
    Rammah, Y. S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2020, 464 (464): : 45 - 55
  • [45] V(T) (TRACK ETCH RATE) - REFLECTION OF TOTAL ENERGY-LOSS RATE (DE/DX) FOR U-238 IN CR-39
    RAJU, J
    DWIVEDI, KK
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 22 (1-4): : 149 - 152
  • [46] Watching at the correlation between the specific track-etch rate and the primary physical parameters of the swift ion interaction with the CR-39
    Fromm, M
    Vaginay, F
    Meesen, G
    Chambaudet, A
    Poffijn, A
    RADIATION MEASUREMENTS, 2003, 36 (1-6) : 93 - 98
  • [47] Influence of pre-exposure thermal annealing on etch rates of CR-39 nuclear track detectors: New findings
    Saad, A.F.
    Gendya, Amany T.
    Rana, Mukhtar Ahmed
    Abdalla, Y.K.
    Hussein, N.A.
    Dawood, Mahmoud S.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2021, 1014
  • [48] Influence of pre-exposure thermal annealing on etch rates of CR-39 nuclear track detectors: New findings
    Saad, A. F.
    Gendya, Amany T.
    Rana, Mukhtar Ahmed
    Abdalla, Y. K.
    Hussein, N. A.
    Dawood, Mahmoud S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1014
  • [49] Radon Exhalation Rate from Building Materials Using CR-39 Nuclear Track Detector
    Topcu, N.
    Bicak, D.
    Cam, S.
    Erees, F. S.
    INDOOR AND BUILT ENVIRONMENT, 2013, 22 (02) : 384 - 387
  • [50] Studying 222Rn exhalation rate from soil and sand samples using CR-39 detector
    Shafi-ur-Rehman
    Matiullah
    Shakeel-ur-Rehman
    Rahman, Said
    RADIATION MEASUREMENTS, 2006, 41 (06) : 708 - 713