Dose-rate effects on the bulk etch-rate of CR-39 track detector exposed to low-LET radiations

被引:25
|
作者
Yamauchi, T
Taniguchi, T
Oda, K
Ikeda, T
Honda, Y
Tagawa, S
机构
[1] Kobe Univ Mercantile Marine, Dept Nucl Engn, Higashinada Ku, Kobe, Hyogo 658, Japan
[2] Osaka Univ, Inst Sci & Ind Res, Ibaraki, Osaka 567, Japan
关键词
CR-39; track detector; gamma-ray; pulsed electron; absorbed dose; dose rate; bulk etch rate; irradiation damage; oxygen;
D O I
10.1016/S1350-4487(99)00132-8
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The effect of gammna-rays and pulsed electrons has been investigated on the bulk etch rate of CR-39 detector at doses up to 100 kGy under various dose-rate between 0.0044 and 35.0 Gy/s. The bulk etch rate increased exponentially with the dose at every examined dose-rates. It was reveled to be strongly depend on the dose-rate: the bulk etch rate was decreased with increasing dose-rate at the same total dose. A primitive model was proposed to explain the dose-rate effect in which oxygen dissolved Was assumed to dominate the damage formation process.
引用
收藏
页码:121 / 126
页数:6
相关论文
共 50 条
  • [1] Effects of low-let radiations on CR-39 track detector
    Oda, K
    Yoshida, K
    Yamauchi, T
    Honda, Y
    Ikeda, T
    Tagawa, S
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 85 - 88
  • [2] Swelling in CR-39 and its effect on bulk etch-rate
    Malik, F
    Khan, EU
    Qureshi, IE
    Husaini, SN
    Sajid, M
    Karim, S
    Jamil, K
    RADIATION MEASUREMENTS, 2002, 35 (04) : 301 - 305
  • [3] DOSE-RATE EFFECTS ON CR-39 SSNT DETECTOR
    ZAMANI, M
    SAMPSONIDIS, D
    CHARALAMBOUS, S
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 125 - 128
  • [4] Effects of stirring on the bulk etch rate of CR-39 detector
    Ho, JPY
    Yip, CWY
    Nikezic, D
    Yu, KN
    RADIATION MEASUREMENTS, 2003, 36 (1-6) : 141 - 143
  • [5] Bulk Etch Rate of CR-39 Track Detector Exposed to Gamma Dose Using D-Le Method
    Kasim, Y. Y.
    JORDAN JOURNAL OF PHYSICS, 2015, 8 (04): : 217 - 226
  • [6] Effects of Chemical Solution Temperature on the Bulk Etch Rate of the Detector CR-39
    Al-Nia'emi, Sa'eed Hassan Sa'eed
    JORDAN JOURNAL OF PHYSICS, 2015, 8 (01): : 49 - 55
  • [7] Surface layer in CR-39 plastic track detector where the bulk etch rate is enhanced
    Yamauchi, T
    EL-Rahmany, A
    Mineyama, D
    Nakai, H
    Oda, K
    RADIATION MEASUREMENTS, 2003, 37 (02) : 119 - 125
  • [8] Interrelated temperature dependence of bulk etch rate and track length saturation time in CR-39 detector
    Azooz, A. A.
    Al-Jubbori, M. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 316 : 171 - 175
  • [9] DOSE-RATE DEPENDENCE ON THE RESPONSE OF CR-39 SSNT-DETECTOR
    ZAMANI, M
    CHARALAMBOUS, S
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1985, 36 (07): : 525 - 529
  • [10] Determination of the Bulk Etch Rate of the Nuclear Track Detector CR-39 Using Le-D Method
    Al-Nia'emi, S. H. S.
    Kasim, Y. Y.
    JORDAN JOURNAL OF PHYSICS, 2013, 6 (01): : 17 - 25