Dose-rate effects on the bulk etch-rate of CR-39 track detector exposed to low-LET radiations

被引:25
|
作者
Yamauchi, T
Taniguchi, T
Oda, K
Ikeda, T
Honda, Y
Tagawa, S
机构
[1] Kobe Univ Mercantile Marine, Dept Nucl Engn, Higashinada Ku, Kobe, Hyogo 658, Japan
[2] Osaka Univ, Inst Sci & Ind Res, Ibaraki, Osaka 567, Japan
关键词
CR-39; track detector; gamma-ray; pulsed electron; absorbed dose; dose rate; bulk etch rate; irradiation damage; oxygen;
D O I
10.1016/S1350-4487(99)00132-8
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The effect of gammna-rays and pulsed electrons has been investigated on the bulk etch rate of CR-39 detector at doses up to 100 kGy under various dose-rate between 0.0044 and 35.0 Gy/s. The bulk etch rate increased exponentially with the dose at every examined dose-rates. It was reveled to be strongly depend on the dose-rate: the bulk etch rate was decreased with increasing dose-rate at the same total dose. A primitive model was proposed to explain the dose-rate effect in which oxygen dissolved Was assumed to dominate the damage formation process.
引用
收藏
页码:121 / 126
页数:6
相关论文
共 50 条
  • [31] Dose rate effects of low-LET ionizing radiation on fish cells
    Vo, Nguyen T. K.
    Seymour, Colin B.
    Mothersill, Carmel E.
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2017, 56 (04) : 433 - 441
  • [32] Evaluating uncertainty in dose and dose-rate effectiveness factors for low-let radiation for use in risk estimation
    Trabalk, JR
    Apostoaei, AI
    Hoffman, FO
    Kocher, DC
    Thomas, BA
    HEALTH PHYSICS, 2005, 89 (01): : S53 - S53
  • [33] Dose rate effects of low-LET ionizing radiation on fish cells
    Nguyen T. K. Vo
    Colin B. Seymour
    Carmel E. Mothersill
    Radiation and Environmental Biophysics, 2017, 56 : 433 - 441
  • [34] Radon Exhalation Rate from Building Materials Using CR-39 Nuclear Track Detector
    Topcu, N.
    Bicak, D.
    Cam, S.
    Erees, F. S.
    INDOOR AND BUILT ENVIRONMENT, 2013, 22 (02) : 384 - 387
  • [35] Can track-etch detector CR-39 record low-velocity GUT magnetic monopoles?
    He, YD
    PHYSICAL REVIEW D, 1998, 57 (05): : 3182 - 3185
  • [36] A STUDY OF CR-39 BULK ETCH PROPERTIES UNDER VARIOUS TEMPERATURE AND CONCENTRATION CONDITIONS TO MODELIZE THE DISSOLUTION RATE
    FROMM, M
    MEMBREY, F
    CHAMBAUDET, A
    SAOULI, R
    ELRAHAMANY, A
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1991, 19 (1-4): : 169 - 170
  • [37] Study of variations in structural, optical parameters and bulk etch rate of CR-39 polymer due to electron irradiation
    Sahoo, G. S.
    Tripathy, S. P.
    Joshi, D. S.
    Bandyopadhyay, T.
    JOURNAL OF APPLIED PHYSICS, 2016, 120 (02)
  • [38] V(T) (TRACK ETCH RATE) - REFLECTION OF TOTAL ENERGY-LOSS RATE (DE/DX) FOR U-238 IN CR-39
    RAJU, J
    DWIVEDI, KK
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 22 (1-4): : 149 - 152
  • [39] Many-hit model calculations for track etch rate in CR-39 SSNTD using confocal microscope data
    Fromm, M
    Awad, EM
    Ditlov, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 226 (04): : 565 - 574
  • [40] Applicability of the multi-hit model to calculate the track etch rate in μm-scale in CR-39 detectors
    Awad, EM
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2003, 158 (07): : 539 - 550