FEMORAL REVISION WITH UNCEMENTED TAPERED STEMS: FROM MONOBLOCK TO MODULAR

被引:0
|
作者
Regis, D. [1 ]
Sandri, A. [1 ]
Bonetti, I. [1 ]
Bartolozzi, P. [1 ]
机构
[1] Univ Verona, Ist Clin Ortoped & Traumatol, Policlin GB Rossi, I-37134 Verona, Italy
来源
MINERVA ORTOPEDICA E TRAUMATOLOGICA | 2009年 / 60卷 / 06期
关键词
Femoral revision; Modular stem; Revision hip arthroplasty; Tapered stem; TOTAL HIP-ARTHROPLASTY; DISTAL FIXATION; FOLLOW-UP; PROSTHESIS; COMPONENTS; TITANIUM;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aim In revision hip surgery, the use of Wagner SL tapered stem involved serious complications, such as subsidence and dislocation, promoting the development of modular components. Comparative results between monoblock and modular stems are reported. Methods. Since 1992, we have performed uncemented femoral revisions with use of fluted, tapered stems, beginning with Wagner SL monoblock prosthesis (68 cases) followed by Profemur R modular stem (104 cases). The comparison was performed assessing several parameters: stem removal due to infection, revision of the stem for aseptic loosening, occurrence of subsidence and dislocation. Results. Two Wagner prostheses (2.9%) and five Profemur R (4.8%) were removed because of deep infection. No stem required revision for aseptic loosening in both groups. Subsidence of the femoral component was observed in 11 cases treated with monoblock stems (16.1%) and in 3 patients who received modular prostheses (2.9%). In both groups, one stem underwent revision for head-neck disassembly following subsidence. Dislocation occurred in six patients of the Wagner group (9.1%) and in seven hips of the Profemur R group (6.8%). Conclusion. The absence of aseptic femoral stem loosening in both groups documents the validity of fluted, tapered fixation on the diaphyseal cortical bone. The occurrence of serious complications resulted the only reason for further femoral revisions. Modularity promotes the achievement of optimal mechanical behaviour of prosthetic joint. Moreover, availability of the interchangeable neck allows to easily and safely modify intraoperatively the final length and orientation of the prosthesis.
引用
收藏
页码:481 / 486
页数:6
相关论文
共 50 条
  • [1] Cementless femoral revision: The role of monoblock versus modular stems
    Sporer, Scott M.
    Paprosky, Wayne G.
    CURRENT ORTHOPAEDICS, 2006, 20 (03): : 171 - 178
  • [2] No Difference in Subsidence Between Modern Monoblock and Modular Titanium Fluted Tapered Femoral Stems
    Pomeroy, Eoghan
    Lim, Jason B. T.
    Vasarhelyi, Edward M.
    Naudie, Douglas D. R.
    Lanting, Brent
    MacDonald, Steven J.
    McCalden, Richard W.
    Howard, James L.
    JOURNAL OF ARTHROPLASTY, 2023, 38 (07): : S223 - S228
  • [3] Outcome of a modular tapered uncemented titanium femoral stem in revision hip arthroplasty
    Maik Hoberg
    Christian Konrads
    Jana Engelien
    Dorothee Oschmann
    Michael Holder
    Matthias Walcher
    Maximilian Rudert
    International Orthopaedics, 2015, 39 : 1709 - 1713
  • [4] Outcome of a modular tapered uncemented titanium femoral stem in revision hip arthroplasty
    Hoberg, Maik
    Konrads, Christian
    Engelien, Jana
    Oschmann, Dorothee
    Holder, Michael
    Walcher, Matthias
    Rudert, Maximilian
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (09) : 1709 - 1713
  • [5] Revision arthroplasty for periprosthetic femoral fracture using an uncemented modular tapered conical stem
    da Assuncao, R. E.
    Pollard, T. C. B.
    Hrycaiczuk, A.
    Curry, J.
    Glyn-Jones, S.
    Taylor, A.
    BONE & JOINT JOURNAL, 2015, 97B (08): : 1031 - 1037
  • [6] Improved outcome in femoral revision arthroplasty with tapered fluted modular titanium stems
    Garbuz, Donald S.
    Toms, Andrew
    Masri, Bassam A.
    Duncan, Clive P.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (453) : 199 - 202
  • [7] Custom uncemented revision stems based on a femoral classification
    Hua, Jia
    Walker, Peter S.
    Muirhead-Allwood, Sarah K.
    Engelhardt, Fred
    Bentley, George
    HIP INTERNATIONAL, 2010, 20 (01) : 18 - 25
  • [8] CORROSION AND WEAR AT THE MODULAR INTERFACE OF UNCEMENTED FEMORAL STEMS
    COOK, SD
    BARRACK, RL
    CLEMOW, AJT
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (01): : 68 - 72
  • [9] Is There a Difference Between Modular Versus Monoblock Femoral Stems Used During Revision Total Hip Arthroplasty?
    Shahi, Alisina
    Bezwada, Hari
    Kendoff, Daniel
    Sadek, Fouad
    Duran, Margarita Veloso
    Winkler, Heinz
    Wang, Weijun
    Zhang, Xiaogang
    JOURNAL OF ARTHROPLASTY, 2025, 40 (02): : s171 - s172
  • [10] The use of tapered stems for femoral revision surgery
    Böhm, P
    Bischel, O
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (420) : 148 - 159