No Difference in Subsidence Between Modern Monoblock and Modular Titanium Fluted Tapered Femoral Stems

被引:2
|
作者
Pomeroy, Eoghan [1 ]
Lim, Jason B. T. [2 ]
Vasarhelyi, Edward M. [3 ,4 ]
Naudie, Douglas D. R. [3 ,4 ]
Lanting, Brent [3 ,4 ]
MacDonald, Steven J. [3 ,4 ]
McCalden, Richard W. [3 ,4 ]
Howard, James L. [3 ,4 ]
机构
[1] Univ Hosp Waterford, Dept Trauma & Orthopaed, Waterford, Ireland
[2] Singapore Gen Hosp, Dept Orthopaed Surg, Singapore, Singapore
[3] Western Univ, Schulich Sch Med & Dent, Dept Surg, Div Orthopaed Surg, London, ON, Canada
[4] London Hlth Sci Ctr, London, ON, Canada
来源
JOURNAL OF ARTHROPLASTY | 2023年 / 38卷 / 07期
关键词
revision total hip arthroplasty; TFT stems; monoblock versus modular; stem subsidence; bicortical contact; TOTAL HIP-ARTHROPLASTY; VANCOUVER B2; SHORT-TERM; REVISION; OUTCOMES; STABILITY; DESIGNS; FEMUR; RISK;
D O I
10.1016/j.arth.2023.03.034
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Subsidence remains a concern when utilizing tapered fluted titanium (TFT) femoral stems and may lead to leg length discrepancy, impingement, instability, and failure to obtain osseointegration. This study aims to compare stem subsidence across 3 modern TFT stems. Our secondary aim was to investigate the influence of bicortical contact or "scratch fit" on subsidence, as well as the role of intraoperative imaging in maximizing bicortical contact and preventing stem subsidence. Methods: A retrospective review of 271 hip arthroplasties utilizing modern TFT stems at a single institution was performed. Three stem designs were included in the analysis: 1 monoblock TFT stem (n = 91) and 2 modular TFT stems (n = 90; n = 90). Patient demographics, Paprosky femoral bone loss classification, bicortical contact, utilization of intraoperative imaging, and stem subsidence (comparison of initial postoperative radiograph to the latest follow-up radiograph-minimum 3 months) were recorded. Results: There was no statistically significant difference in overall subsidence (P = .191) or the incidence of subsidence >5 millimeters between stems (P = .126). Subgroup analysis based on femoral bone loss grading showed no difference in subsidence between stems. Increased bicortical contact was associated with reduced subsidence (P = .004). Intraoperative imaging was used in 46.5% (126 of 271) of cases; this was not correlated with bicortical contact (P = .673) or subsidence (P = .521). Conclusion: All 3 modern TFT stems were highly successful and associated with low rates of subsidence, regardless of modular or monoblock design. Surgeons should select the stem that they feel is most clinically appropriate. (c) 2023 Elsevier Inc. All rights reserved.
引用
收藏
页码:S223 / S228
页数:6
相关论文
共 50 条
  • [1] Improved outcome in femoral revision arthroplasty with tapered fluted modular titanium stems
    Garbuz, Donald S.
    Toms, Andrew
    Masri, Bassam A.
    Duncan, Clive P.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (453) : 199 - 202
  • [2] Incidence and Predictors of Subsidence Using Modular, Tapered, Fluted Titanium Femoral Stems in Aseptic Revision Total Hip Arthroplasty
    Baldwin, Thomas J.
    Deckard, Evan R.
    Buller, Leonard T.
    Meneghini, R. Michael
    JOURNAL OF ARTHROPLASTY, 2024, 39 (05): : 1304 - 1311
  • [3] What Is the Difference Between Modular and Nonmodular Tapered Fluted Titanium Stems in Revision Total Hip Arthroplasty
    Huang, Yong
    Zhou, Yixin
    Shao, Hongyi
    Gu, Jianming
    Tang, Hao
    Tang, Qiheng
    JOURNAL OF ARTHROPLASTY, 2017, 32 (10): : 3108 - 3113
  • [4] FEMORAL REVISION WITH UNCEMENTED TAPERED STEMS: FROM MONOBLOCK TO MODULAR
    Regis, D.
    Sandri, A.
    Bonetti, I.
    Bartolozzi, P.
    MINERVA ORTOPEDICA E TRAUMATOLOGICA, 2009, 60 (06): : 481 - 486
  • [5] Femoral Bone Remodeling in Revision Total Hip Arthroplasty with Use of Modular Compared with Monoblock Tapered Fluted Titanium Stems The Role of Stem Length and Stiffness
    Huang, Yong
    Shao, Hongyi
    Zhou, Yixin
    Gu, Jianming
    Tang, Hao
    Yang, Dejin
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2019, 101 (06): : 531 - 538
  • [6] Patterns of Osseointegration and Remodeling in Femoral Revision With Bone Loss Using Modular, Tapered, Fluted, Titanium Stems
    Rodriguez, Jose A.
    Deshmukh, Ajit J.
    Klauser, Wolfgang U.
    Rasquinha, Vijay J.
    Lubinus, Philipp
    Ranawat, Chitranjan S.
    JOURNAL OF ARTHROPLASTY, 2011, 26 (08): : 1409 - 1417
  • [7] Tapered, fluted, modular, titanium stems in Vancouver B periprosthetic femoral fractures: an analysis of 87 consecutive revisions
    van Laarhoven, Simon N.
    Vles, Georges F.
    van Haaren, Emil H.
    Schotanus, Martijn G. M.
    van Hemert, Wouter L. W.
    HIP INTERNATIONAL, 2021, 31 (04) : 555 - 561
  • [8] Modular Fluted Tapered Stems for Periprosthetic Femoral Fractures Excellent Results in 171 Cases
    Hannon, Charles P.
    Sheehan, Kevin P.
    Duong, Stephanie Q.
    Yuan, Brandon J.
    Lewallen, David G.
    Berry, Daniel J.
    Abdel, Matthew P.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2022, 104 (13): : 1188 - 1196
  • [9] Is There a Difference Between Modular Versus Monoblock Femoral Stems Used During Revision Total Hip Arthroplasty?
    Shahi, Alisina
    Bezwada, Hari
    Kendoff, Daniel
    Sadek, Fouad
    Duran, Margarita Veloso
    Winkler, Heinz
    Wang, Weijun
    Zhang, Xiaogang
    JOURNAL OF ARTHROPLASTY, 2025, 40 (02): : s171 - s172
  • [10] Role and results of tapered fluted modular titanium stems in revision total hip arthroplasty
    Munro, J. T.
    Garbuz, D. S.
    Masri, B. A.
    Duncan, C. P.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (11): : 58 - 60