No Difference in Subsidence Between Modern Monoblock and Modular Titanium Fluted Tapered Femoral Stems

被引:2
|
作者
Pomeroy, Eoghan [1 ]
Lim, Jason B. T. [2 ]
Vasarhelyi, Edward M. [3 ,4 ]
Naudie, Douglas D. R. [3 ,4 ]
Lanting, Brent [3 ,4 ]
MacDonald, Steven J. [3 ,4 ]
McCalden, Richard W. [3 ,4 ]
Howard, James L. [3 ,4 ]
机构
[1] Univ Hosp Waterford, Dept Trauma & Orthopaed, Waterford, Ireland
[2] Singapore Gen Hosp, Dept Orthopaed Surg, Singapore, Singapore
[3] Western Univ, Schulich Sch Med & Dent, Dept Surg, Div Orthopaed Surg, London, ON, Canada
[4] London Hlth Sci Ctr, London, ON, Canada
来源
JOURNAL OF ARTHROPLASTY | 2023年 / 38卷 / 07期
关键词
revision total hip arthroplasty; TFT stems; monoblock versus modular; stem subsidence; bicortical contact; TOTAL HIP-ARTHROPLASTY; VANCOUVER B2; SHORT-TERM; REVISION; OUTCOMES; STABILITY; DESIGNS; FEMUR; RISK;
D O I
10.1016/j.arth.2023.03.034
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Subsidence remains a concern when utilizing tapered fluted titanium (TFT) femoral stems and may lead to leg length discrepancy, impingement, instability, and failure to obtain osseointegration. This study aims to compare stem subsidence across 3 modern TFT stems. Our secondary aim was to investigate the influence of bicortical contact or "scratch fit" on subsidence, as well as the role of intraoperative imaging in maximizing bicortical contact and preventing stem subsidence. Methods: A retrospective review of 271 hip arthroplasties utilizing modern TFT stems at a single institution was performed. Three stem designs were included in the analysis: 1 monoblock TFT stem (n = 91) and 2 modular TFT stems (n = 90; n = 90). Patient demographics, Paprosky femoral bone loss classification, bicortical contact, utilization of intraoperative imaging, and stem subsidence (comparison of initial postoperative radiograph to the latest follow-up radiograph-minimum 3 months) were recorded. Results: There was no statistically significant difference in overall subsidence (P = .191) or the incidence of subsidence >5 millimeters between stems (P = .126). Subgroup analysis based on femoral bone loss grading showed no difference in subsidence between stems. Increased bicortical contact was associated with reduced subsidence (P = .004). Intraoperative imaging was used in 46.5% (126 of 271) of cases; this was not correlated with bicortical contact (P = .673) or subsidence (P = .521). Conclusion: All 3 modern TFT stems were highly successful and associated with low rates of subsidence, regardless of modular or monoblock design. Surgeons should select the stem that they feel is most clinically appropriate. (c) 2023 Elsevier Inc. All rights reserved.
引用
收藏
页码:S223 / S228
页数:6
相关论文
共 50 条
  • [41] Femoral revision with a fluted, tapered, modular stem - Seventy patients followed for a mean of 3.9 years
    McInnis, DP
    Horne, G
    Devane, PA
    JOURNAL OF ARTHROPLASTY, 2006, 21 (03): : 372 - 380
  • [42] The relationship between stem subsidence and improvement in the radiolucency in polished tapered stems
    Kaneuji, Ayumi
    Sugimori, Tanzo
    Ichiseki, Toru
    Fukui, Kiyokazu
    Yamada, Kengo
    Matsumoto, Tadami
    INTERNATIONAL ORTHOPAEDICS, 2006, 30 (05) : 387 - 390
  • [43] The relationship between stem subsidence and improvement in the radiolucency in polished tapered stems
    Ayumi Kaneuji
    Tanzo Sugimori
    Toru Ichiseki
    Kiyokazu Fukui
    Kengo Yamada
    Tadami Matsumoto
    International Orthopaedics, 2006, 30 : 387 - 390
  • [44] CORR Insights®: Nonmodular Tapered Fluted Titanium Stems Osseointegrate Reliably at Short Term in Revision THAs
    Streit, Marcus R.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2017, 475 (01) : 193 - 195
  • [45] Cementless Tapered Wedge Femoral Stems Decrease Subsidence in Obese Patients Compared to Traditional Fit-and-Fill Stems
    Grant, Tanner W.
    Lovro, Luke R.
    Licini, David J.
    Warth, Lucian C.
    Ziemba-Davis, Mary
    Meneghini, Robert M.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (03): : 891 - 897
  • [46] Uncemented femoral revision arthroplasty using a modular tapered, fluted titanium stem 5-to 16-year results of 163 cases
    Wirtz, Dieter C.
    Gravius, Sascha
    Ascherl, Rudolf
    Thorweihe, Miguel
    Forst, Raimund
    Noeth, Ulrich
    Maus, Uwe M.
    Wimmer, Matthias D.
    Zeiler, Guenther
    Deml, Moritz C.
    ACTA ORTHOPAEDICA, 2014, 85 (06) : 562 - 569
  • [47] Midterm results and complications rates in vancouver type B2 and B3 periprosthetic femoral fractures treated with modular fluted tapered stems
    Santiago, L. Iglesias
    Gerardo, Aguirre
    Fernando, Vanoli
    Leonel, Perez Alamino
    Ignacio, Pioli
    Pablo, Maletti
    Fernando, A. Lopreite
    Hernan, Del Sel
    Bartolome, L. Allende
    JOURNAL OF ORTHOPAEDICS, 2021, 28 : 1 - 4
  • [48] SUCCESSFUL FEMORAL RECONSTRUCTION WITH A FLUTED AND TAPERED MODULAR DISTAL FIXATION STEM IN REVISION TOTAL HIP ARTHROPLASTY
    Skytta, E. T.
    Eskelinen, A.
    Remes, V.
    SCANDINAVIAN JOURNAL OF SURGERY, 2012, 101 (03) : 222 - 226
  • [49] Revision total hip arthroplasty in patients with extensive proximal femoral bone loss using a fluted tapered modular femoral component
    Amanatullah, D. F.
    Howard, J. L.
    Siman, H.
    Trousdale, R. T.
    Mabry, T. M.
    Berry, D. J.
    BONE & JOINT JOURNAL, 2015, 97B (03): : 312 - 317
  • [50] Results of Revision Total Hip Arthroplasty with Modular, Titanium-Tapered Femoral Stems in Severe Proximal Metaphyseal and Diaphyseal Bone Loss
    Palumbo, Brian T.
    Morrison, Kurt L.
    Baumgarten, Adam S.
    Stein, Mathew I.
    Haidukewych, George J.
    Bernasek, Thomas L.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (04): : 690 - 694