SUCCESSFUL FEMORAL RECONSTRUCTION WITH A FLUTED AND TAPERED MODULAR DISTAL FIXATION STEM IN REVISION TOTAL HIP ARTHROPLASTY

被引:9
|
作者
Skytta, E. T. [1 ,2 ]
Eskelinen, A. [1 ]
Remes, V. [3 ]
机构
[1] COXA Hosp Joint Replacement, Tampere, Finland
[2] Tampere Univ Hosp, Ctr Rheumat Dis, Dept Orthopaed, Tampere, Finland
[3] Univ Helsinki, Cent Hosp, Dept Orthoped & Traumatol, Peijas Hosp, Helsinki, Finland
关键词
Total hip arthroplasty; revision; femur; distal fixation; survival; complication; periprosthetic fracture; FOLLOW-UP; 2-YEAR;
D O I
10.1177/145749691210100314
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background and Aims: Early results of fluted and tapered distal fixation stems used in reconstruction of deficient femora in femoral revision arthroplasty have been successful in small series. We evaluated the survival of the LINK MP Reconstruction Hip Stem and factors associated with survival using data from a nation-wide arthroplasty register. Materials and Methods: 408 femoral revisions using LINK MP Reconstruction Hip Stem were performed during 1994 to 2007. The mean age of the patients was 72.5 (range: 36-93) years and 63% were performed in women. Kaplan-Meier analysis and the Cox regression model were used for the survival analysis. The effects of age, sex and diagnoses were also studied. Results: The 9-year overall survivorship for the LINK MP Reconstruction Hip Stem was 75% (95% CI 70-80). Aseptic loosening was rare; the 9-year revision rate for aseptic loosening was only 3%, which coincides with earlier reports with shorter folllow-up. The most common reason for re-revision was dislocation of the prosthesis with or without malposition of the socket (67%). Indication for revision strongly affected the survival rate with revisions for dislocation having an over 3-fold and revisions for infection a 3-fold relative risk for re-revision compared to revisions for aseptic loosening. Increasing age slightly decreased the risk of re-revision but sex did not affect the survival. Discussion: Based on our findings, we conclude LINK MP Reconstruction Hip Stem, as an example of a fluted and tapered distal fixation stem, appears to solve many problems with implant fixation in femoral revisions. High number of dislocations suggests that special attention should be paid to correct center of rotation, to correct implant positioning and to need of constrained implants in case of deficient abductor mechanism.
引用
收藏
页码:222 / 226
页数:5
相关论文
共 50 条
  • [1] Revision Total Hip Arthroplasty with a Modular Fluted Tapered Stem for a Periprosthetic Femoral Fracture
    Hannon, Charles P. P.
    Abdel, Matthew P. P.
    [J]. JBJS ESSENTIAL SURGICAL TECHNIQUES, 2023, 13 (03):
  • [2] Revision total hip arthroplasty using a fluted and tapered modular distal fixation stem with and without extended trochanteric osteotomy
    Park, Youn-Soo
    Moon, Young-Wan
    Lim, Seung-Jae
    [J]. JOURNAL OF ARTHROPLASTY, 2007, 22 (07): : 993 - 999
  • [3] Modular Fluted Tapered Stems in Aseptic Revision Total Hip Arthroplasty
    Abdel, Matthew P.
    Cottino, Umberto
    Larson, Dirk R.
    Hanssen, Arlen D.
    Lewallen, David G.
    Berry, Daniel J.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2017, 99 (10): : 873 - 881
  • [4] A Distal Fluted, Proximal Modular Femoral Prosthesis in Revision Hip Arthroplasty
    Park, Myung-Sik
    Lee, Ju-Hong
    Park, Jong-Hyuk
    Ham, Dong-Hun
    Rhee, Yang-Keun
    [J]. JOURNAL OF ARTHROPLASTY, 2010, 25 (06): : 932 - 938
  • [5] Revision total hip arthroplasty with a modular tapered stem
    Lakstein, Dror
    Kosashvili, Yona
    Backstein, David
    Safir, Oleg
    Lee, Paul
    Gross, Allan E.
    [J]. HIP INTERNATIONAL, 2010, 20 (02) : 136 - 142
  • [6] Fixation with a modular stem in revision total hip arthroplasty
    Bono, JV
    McCarthy, JC
    Lee, JA
    Carangelo, RJ
    Turner, RH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (09): : 1326 - 1336
  • [7] Implant breakage and revision factors for modular fluted tapered stems in revision total hip arthroplasty
    Lucena, Thibaut
    Cavaignac, Etienne
    Courtot, Louis
    Marot, Vincent
    Chiron, Philippe
    Reina, Nicolas
    [J]. HIP INTERNATIONAL, 2024, 34 (02) : 207 - 214
  • [8] Revision total hip arthroplasty in patients with extensive proximal femoral bone loss using a fluted tapered modular femoral component
    Amanatullah, D. F.
    Howard, J. L.
    Siman, H.
    Trousdale, R. T.
    Mabry, T. M.
    Berry, D. J.
    [J]. BONE & JOINT JOURNAL, 2015, 97B (03): : 312 - 317
  • [9] Role and results of tapered fluted modular titanium stems in revision total hip arthroplasty
    Munro, J. T.
    Garbuz, D. S.
    Masri, B. A.
    Duncan, C. P.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (11): : 58 - 60
  • [10] Clinical, radiographic, and survivorship analysis of a modular fluted tapered stem in revision hip arthroplasty
    Ferraz Picado, Celso Herminio
    Savarese, Aniello
    Cardamoni, Vitor dos Santos
    Sugo, Arthur Tomotaka
    Garcia, Flavio Luis
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY, 2020, 28 (01)