Outcome of a modular tapered uncemented titanium femoral stem in revision hip arthroplasty

被引:24
|
作者
Hoberg, Maik [1 ]
Konrads, Christian [1 ]
Engelien, Jana [1 ]
Oschmann, Dorothee [1 ]
Holder, Michael [1 ]
Walcher, Matthias [1 ]
Rudert, Maximilian [1 ]
机构
[1] Univ Wurzburg, Ctr Musculoskeletal Res, Orthopaed Clin Koenig Ludwig Haus, D-97074 Wurzburg, Germany
关键词
Femoral stem exchange; Hip revision arthroplasty; MRP-TITAN; Cementless; Modular; FOLLOW-UP; REPLACEMENT; PROSTHESIS; IMPLANT;
D O I
10.1007/s00264-015-2699-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Revision hip arthroplasty using a modular tapered design gives the possibility for customising the prostheses to the individual anatomy intra-operatively. The success of this kind of surgery is still controversial due to the relative lack of medium- to long-term follow-up. Therefore we analysed the clinical and radiological outcome of the modular MRP-TITAN stem with diaphyseal fixation in revision hip surgery. Methods In this retrospective study we included 136 consecutive patients with MRP-TITAN stem implanted during revision hip arthroplasty. The average follow-up was 55 months. For clinical evaluation we used the Harris Hip Score and the Merle d'Aubign, and Postel score. The health-related quality of life was determined with the visual analogue pain scale. Results The surgeries were performed 109 months after primary total hip arthroplasty on average. The main indications for the MRP-TITAN revision stem were aseptic loosening, infection, and periprosthetic fracture. In the clinical outcome, patients achieved 75.1 points in the Harris Hip Score and 14.4 points in the Merle d'Aubign, and Postel Score. Mean level of persisting pain was 0.7 (VAS). The overall survival of the MRP stem in revision hip arthroplasty revealed 85.6 % survival at 9.75 years' follow-up with a repeat revision rate of 6.8 %. Conclusions Performing revision hip arthroplasty using the MRP-TITAN stem revealed a good clinical outcome. There is a tendency for better results in comparison with the information given in literature for cementless modular revision stems including a lower rate in re-revisions.
引用
收藏
页码:1709 / 1713
页数:5
相关论文
共 50 条
  • [1] Outcome of a modular tapered uncemented titanium femoral stem in revision hip arthroplasty
    Maik Hoberg
    Christian Konrads
    Jana Engelien
    Dorothee Oschmann
    Michael Holder
    Matthias Walcher
    Maximilian Rudert
    [J]. International Orthopaedics, 2015, 39 : 1709 - 1713
  • [2] Revision arthroplasty for periprosthetic femoral fracture using an uncemented modular tapered conical stem
    da Assuncao, R. E.
    Pollard, T. C. B.
    Hrycaiczuk, A.
    Curry, J.
    Glyn-Jones, S.
    Taylor, A.
    [J]. BONE & JOINT JOURNAL, 2015, 97B (08): : 1031 - 1037
  • [3] Improved outcome in femoral revision arthroplasty with tapered fluted modular titanium stems
    Garbuz, Donald S.
    Toms, Andrew
    Masri, Bassam A.
    Duncan, Clive P.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (453) : 199 - 202
  • [4] Revision total hip arthroplasty with a modular tapered stem
    Lakstein, Dror
    Kosashvili, Yona
    Backstein, David
    Safir, Oleg
    Lee, Paul
    Gross, Allan E.
    [J]. HIP INTERNATIONAL, 2010, 20 (02) : 136 - 142
  • [5] Revision Total Hip Arthroplasty with a Modular Fluted Tapered Stem for a Periprosthetic Femoral Fracture
    Hannon, Charles P. P.
    Abdel, Matthew P. P.
    [J]. JBJS ESSENTIAL SURGICAL TECHNIQUES, 2023, 13 (03):
  • [6] Modular tapered titanium stems in revision arthroplasty of the hip THE RISK AND CAUSES OF STEM FRACTURE
    Konan, S.
    Garbuz, D. S.
    Masri, B. A.
    Duncan, C. P.
    [J]. BONE & JOINT JOURNAL, 2016, 98B (01): : 50 - 53
  • [7] Revision hip arthroplasty using a cementless modular tapered stem
    Pattyn, Christophe
    Mulliez, Alexander
    Verdonk, Rene
    Audenaert, Emmanuel
    [J]. INTERNATIONAL ORTHOPAEDICS, 2012, 36 (01) : 35 - 41
  • [8] Risk Factors for Subsidence of a Modular Tapered Femoral Stem Used for Revision Total Hip Arthroplasty
    Tangsataporn, Suksan
    Safir, Oleg A.
    Vincent, Alexander D.
    Abdelbary, Hesham
    Gross, Allan E.
    Kuzyk, Paul R. T.
    [J]. JOURNAL OF ARTHROPLASTY, 2015, 30 (06): : 1030 - 1034
  • [9] Revision hip arthroplasty using a cementless modular tapered stem
    Christophe Pattyn
    Alexander Mulliez
    René Verdonk
    Emmanuel Audenaert
    [J]. International Orthopaedics, 2012, 36 : 35 - 41
  • [10] Uncemented femoral revision arthroplasty using a modular tapered, fluted titanium stem 5-to 16-year results of 163 cases
    Wirtz, Dieter C.
    Gravius, Sascha
    Ascherl, Rudolf
    Thorweihe, Miguel
    Forst, Raimund
    Noeth, Ulrich
    Maus, Uwe M.
    Wimmer, Matthias D.
    Zeiler, Guenther
    Deml, Moritz C.
    [J]. ACTA ORTHOPAEDICA, 2014, 85 (06) : 562 - 569