A PCM/heat pipe cooling system for reducing air conditioning in buildings: review of options and report on field tests

被引:22
|
作者
Etheridge, D. [1 ]
Murphy, K. [1 ]
Reay, D. [1 ]
机构
[1] Univ Nottingham, Sch Built Environm, Nottingham NG7 2RD, England
来源
BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY | 2006年 / 27卷 / 01期
关键词
D O I
10.1191/0143624406bt142oa
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Air conditioning is now seen as a new and major contributor to CO2 emissions in the UK. This is partly due to global warming and partly to the increased use of IT systems. A novel system for reducing or eliminating the need for air conditioning was developed to the proof-of-concept stage under an earlier project at the University of Nottingham. The system makes use of heat pipes to transfer heat into and out of a phase change material which is 'frozen' during the night and 'melted' during the day. This paper describes a number of concepts for 'free cooling', and the background to the current concept, before detailing field tests on the system that have recently been completed and which demonstrate its effectiveness under real operating conditions. Systems were installed in two offices and detailed monitoring of their performance was carried out during the summer months. On the basis of the results obtained it is concluded that the system functions very well and is practically and technically the most attractive of the available alternatives to air conditioning. The fact that it is suited to retrofitting in existing buildings means that both the potential market and the CO2 reductions are large. Practical application: The paper describes a novel system that is intended to provide passive cooling in naturally ventilated buildings. The novelty lies in the use of heat pipes and a fan to enhance the heat transfer to and from the phase change material (PCM) and the air. That this has been successful is shown by the ability of the system to exercise a degree of control over the room air temperature that is comparable to that of a conventional airconclitioning system. The review provided in the paper may also be of use to other workers on PCMs and night cooling of naturally ventilated buildings.
引用
收藏
页码:27 / 39
页数:13
相关论文
共 50 条
  • [31] Fully Fresh Air Air-conditioning System Equipped with Double Heat Pipe Based Heat Recovery Technology
    Ahmadzadehtalatapeh, M.
    Yau, Y. H.
    INTERNATIONAL JOURNAL OF ENGINEERING, 2013, 26 (01): : 51 - 57
  • [32] Reducing unwanted thermal gains during the cooling season for a solar heat pipe system
    Robinson, Brian S.
    Sharp, M. Keith
    SOLAR ENERGY, 2015, 115 : 16 - 32
  • [33] Review on heat pump coupled desiccant wheel dehumidification and air conditioning systems in buildings
    Tian, Shaochen
    Su, Xing
    Geng, Yining
    JOURNAL OF BUILDING ENGINEERING, 2022, 54
  • [34] Performance analysis of a dual-stack Air-PCM heat exchanger with novel air flow configuration for cooling applications in buildings
    Dallaire, Jonathan
    Hassan, Hafiz Muhammad Adeel
    Bjernemose, Jesper Holm
    Hansen, Mads Peter Rudolph
    Lund, Ivar
    Veje, Christian T.
    BUILDING AND ENVIRONMENT, 2022, 223
  • [35] Development of a cooling load prediction model for air-conditioning system control of office buildings
    Fan, Chengliang
    Liao, Yundan
    Ding, Yunfei
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2019, 14 (01) : 70 - 75
  • [36] THERMAL PERFORMANCE ENHANCEMENT OF HEAT PIPE HEAT EXCHANGER IN THE AIR-CONDITIONING SYSTEM BY USING NANOFLUID
    Abdallah, Ayad S.
    Yasin, Nabil Jamil
    Ameen, Hani Aziz
    FRONTIERS IN HEAT AND MASS TRANSFER, 2022, 18
  • [37] An air-conditioning system performance enhancement by using heat pipe based heat recovery technology
    Ahmadzadehtalatapeh, M.
    SCIENTIA IRANICA, 2013, 20 (02) : 329 - 336
  • [38] Free cooling potential of a PCM-based heat exchanger coupled with a novel HVAC system for simultaneous heating and cooling of buildings
    Maccarini, Alessandro
    Hultmark, Goran
    Bergsoe, Niels C.
    Afshari, Alireza
    SUSTAINABLE CITIES AND SOCIETY, 2018, 42 : 384 - 395
  • [39] Novel ventilation system for reducing air conditioning in buildings. Part II: testing of prototype
    Turnpenny, JR
    Etheridge, DW
    Reay, DA
    APPLIED THERMAL ENGINEERING, 2001, 21 (12) : 1203 - 1217
  • [40] PCM assisted heat pipe cooling system for the thermal management of an LTO cell for high-current profiles
    Behi, Hamidreza
    Karimi, Danial
    Gandoman, Foad Heidari
    Akbarzadeh, Mohsen
    Khaleghi, Sahar
    Kalogiannis, Theodoros
    Hosen, Md Sazzad
    Jaguemont, Joris
    Van Mierlo, Joeri
    Berecibar, Maitane
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 25