Reducing unwanted thermal gains during the cooling season for a solar heat pipe system

被引:10
|
作者
Robinson, Brian S. [1 ]
Sharp, M. Keith [1 ]
机构
[1] Univ Louisville, Dept Mech Engn, Renewable Energy Applicat Lab, Louisville, KY 40292 USA
关键词
Heat pipe; Passive solar; Isolated gain; Overheating; PERFORMANCE; BUILDINGS; SUNSPACE; WALL;
D O I
10.1016/j.solener.2015.02.011
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The heat pipe augmented solar heating system significantly reduces heating loads relative to other conventional passive space heating systems. However, thermal gains from the system during the cooling season increase cooling loads and tend to increase overall space conditioning loads. The effectiveness of several design modifications and control strategies for the heat pipe wall to reduce unwanted gains was investigated. Computer algorithms were used to simulate four different unwanted gains reduction mechanisms: shading, an opaque cover, a mechanical valve, and switching the elevations of the evaporator and condenser sections to provide heat transfer out of the room during the cooling season. For each mechanism, three different control strategies were evaluated: (1) Seasonal control, for which the prescribed mechanism was deployed at the beginning and removed at the end of the cooling season, (2) ambient temperature-based control, for which the mechanism was deployed if the forecast for the next hour was greater than 18.3 degrees C (65 degrees F), and (3) room temperature-based control, for which the mechanism was deployed if auxiliary cooling was required for the previous hour. For the seasonal strategy, a season determination (SD) parameter was defined and results suggested that SD may be a 'universal' parameter that can be applied across a range of climates for quick cooling season assessment. The heat pipe system performed best with ambient temperature-based control strategy, and the cover and valve were the best single mechanisms. Experiments on a full-scale heat pipe wall prototype using valve and cover control mechanisms confirmed significant reductions in unwanted thermal gains with little to no increase in room temperature during the testing periods. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:16 / 32
页数:17
相关论文
共 50 条
  • [1] REDUCING UNWANTED GAINS DURING THE COOLING SEASON FROM A HEAT PIPE AUGMENTED PASSIVE SOLAR HEATING SYSTEM
    Robinson, Brian S.
    Sharp, M. Keith
    PROCEEDINGS OF THE ASME 6TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY - 2012, PTS A AND B, 2012, : 59 - +
  • [2] Thermal Comfort Aspects of Solar Gains during the Heating Season
    Kalmar, Ferenc
    Kalmar, Tunde
    ENERGIES, 2020, 13 (07)
  • [3] Thermal performance of an evacuated tube heat pipe solar water heating system in cold season
    Shafieian, Abdellah
    Khiadani, Mehdi
    Nosrati, Ataollah
    APPLIED THERMAL ENGINEERING, 2019, 149 : 644 - 657
  • [4] Heating season performance improvements for a solar heat pipe system
    Robinson, Brian S.
    Sharp, M. Keith
    SOLAR ENERGY, 2014, 110 : 39 - 49
  • [5] Properties of thermal probes with heat pipe cooling system
    Vrager, A
    Tiikma, T
    ADVANCES IN HEAT TRANSFER ENGINEERING, PROCEEDINGS, 2003, : 587 - 594
  • [6] Thermal management system of CPU cooling with a novel short heat pipe cooling system
    Siricharoenpanich, A.
    Wiriyasart, S.
    Srichat, A.
    Naphon, P.
    CASE STUDIES IN THERMAL ENGINEERING, 2019, 15
  • [7] Thermal analysis of hydration heat in concrete structures with pipe-cooling system
    Kim, JK
    Kim, KH
    Yang, JK
    COMPUTERS & STRUCTURES, 2001, 79 (02) : 163 - 171
  • [8] Thermal control of spacebome image sensor using heat pipe cooling system
    Oh, Hyun-Ung
    Shin, Somin
    Baek, Chul-Woo
    AEROSPACE SCIENCE AND TECHNOLOGY, 2013, 29 (01) : 394 - 402
  • [9] Numerical Simulation of Heat Pipe Thermal Performance for Aerospace Cooling System Applications
    Scigliano, Roberto
    De Simone, Valeria
    Fusaro, Roberta
    Ferretto, Davide
    Viola, Nicole
    Souza, Reinaldo R.
    AEROSPACE, 2024, 11 (01)
  • [10] Thermal performance of finned heat pipe system for Central Processing Unit cooling
    Maalej, S.
    Zayoud, A.
    Abdelaziz, I
    Saad, I
    Zaghdoudi, M. C.
    ENERGY CONVERSION AND MANAGEMENT, 2020, 218 (218)