Derivatization of estrogens enhances specificity and sensitivity of analysis of human plasma and serum by liquid chromatography tandem mass spectrometry
被引:54
|作者:
Faqehi, Abdullah M. M.
[1
]
Cobice, Diego F.
[1
]
Naredo, Gregorio
[2
]
Mak, Tracy C. S.
[1
]
Upreti, Rita
[1
]
Gibb, Fraser W.
[1
]
Beckett, Geoffrey J.
[3
]
Walker, Brian R.
[1
,2
]
Homer, Natalie Z. M.
[2
]
Andrew, Ruth
[1
,2
]
机构:
[1] Univ Edinburgh, Queens Med Res Inst, Univ British Heart Fdn Ctr Cardiovasc Sci, Endocrinol, 47 Little France Crescent, Edinburgh EH16 4TJ, Midlothian, Scotland
[2] Queens Med Res Inst, Edinburgh Clin Res Facil, Mass Spectrometry Core, 47 Little France Crescent, Edinburgh EH16 4TJ, Midlothian, Scotland
[3] Royal Infirm Edinburgh NHS Trust, Clin Biochem, 51 Little France Crescent, Edinburgh EH16 4SA, Midlothian, Scotland
来源:
基金:
英国惠康基金;
关键词:
Estrone;
Estradiol;
Derivatization;
Liquid chromatography;
Mass spectrometry;
Methylpyridinium ether;
SOLID-PHASE EXTRACTION;
STEROIDAL ESTROGENS;
SURFACE-WATER;
ESTRADIOL;
ESTRONE;
HORMONES;
QUANTIFICATION;
ASSAY;
D O I:
10.1016/j.talanta.2015.12.062
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
Estrogens circulate at concentrations less than 20 pg/mL in men and postmenopausal women, presenting analytical challenges. Quantitation by immunoassay is unreliable at these low concentrations. Liquid chromatography tandem mass spectrometry (LC-MS/MS) offers greater specificity and sometimes greater sensitivity, but ionization of estrogens is inefficient. Introduction of charged moieties may enhance ionization, but many such derivatives of estrogens generate non-specific product ions originating from the "reagent" group. Therefore an approach generating derivatives with product ions specific to individual estrogens was sought. Estrogens were extracted from human plasma and serum using solid phase extraction and derivatized using 2-fluoro-1-methylpyridinium-p-toluenesulfonate (FMP-TS). Electrospray in positive mode with multiple reaction monitoring using a QTrap 5500 mass spectrometer was used to quantify "FMP" derivatives of estrogens, following LC separation. Transitions for the FMP derivatives of estrone (El) and estradiol (E2) were compound specific (m/z 362 -> 238 and m/z 364 -> 128, respectively). The limits of detection and quantitation were 0.2 pg on column and the method was linear from 1-400 pg/sample. Measures of intra- and inter-assay variability, precision and accuracy were acceptable (< 20%). The derivatives were stable over 24 h at 10 degrees C (7-9% degradation). Using this approach, El and E2, respectively were detected in human plasma and serum: pre-menopausal female serum (0.5 mL) 135-473, 193-722 pmol/L; male plasma (1 mL) 25-111, 60180 pmol/L and post-menopausal female plasma (2 mL), 22-78, 29-50 pmol/L. Thus FMP derivatization, in conjunction with LC-MS/MS, is suitable for quantitative analysis of estrogens in low abundance in plasma and serum, offering advantages in specificity over immunoassay and existing MS techniques. (C) 2016 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).