Design and analysis of microfluidic kidney-on-chip model: fluid shear stress based study with temperature effect

被引:11
|
作者
Sateesh, Jasti [1 ]
Guha, Koushik [1 ]
Dutta, Arindam [2 ]
Sengupta, Pratim [3 ]
Rao, K. Srinivasa [4 ]
机构
[1] Natl Inst Technol Silchar, Natl MEMS Design Ctr, Dept Elect & Commun Engn, Silchar 788010, Assam, India
[2] RG Stone Urol & Laparoscop Hosp, Kolkata, W Bengal, India
[3] Belle Vue Clin, Kolkata, W Bengal, India
[4] KLEF, MEMS Res Ctr, Dept Elect & Commun Engn, Guntur, Andhra Prades, India
关键词
COLLECTING DUCT; CELLS; DISEASE; FLOW;
D O I
10.1007/s00542-018-4261-z
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The flow in the nephron tubules regulates the blood homeostasis, secretion, excretion and reabsorption of solutes. Flow induces fluid shear stress (FSS) on walls of tubules which has substantial effect on kidney functioning. Modelling of FSS mimicking structures is critical for their optimization. In this paper, a compact structure for kidney-on-chip devices is proposed for exact reconstruction of FSS and temperature effect in tubules considering the nephron tubule dimensions for modelling. The proposed system is compartmentalized basically into three parts ultra filter, device structure and reactor. The FSS is analysed for different inflow rates, proving the proposed structure is helpful in balancing the tubuloglomerulo feedback system mimicking. The structure is analysed for different structural changes in benchmark FEM tool COMSOL Multiphysics to optimize it to suite the kidney-on-chip purpose. Pressure achieved at the cell site is 0.1 Pa, which is the pressure applied by FFS on kidney tubules cells. The temperature effect of the human body is considered and the findings are presented. Temperature has an inverse relationship with FSS. At absolute temperature the pressure is 9.7 Pa and reached 3.77 Pa at body temperature, showing a decrease in pressure. The reaction of sodium and calcium is presented to show common reabsorption happening the kidney. The fabrication process flow is implemented in Intellisuite tool which is incorporated here to indicate the device fabrication cost will be low. The proposed Kidney-on-Chip structure finds astounding results make it to use in potential transplantable devices.
引用
收藏
页码:2553 / 2560
页数:8
相关论文
共 50 条
  • [31] Design and simulation study of microfluidic chip based on the liquid quantitative shunting mixing and detecting
    Xing Xiaodong
    Wang Shiyuan
    Jin Ying
    Wang Liquan
    FERROELECTRICS, 2019, 546 (01) : 57 - 66
  • [32] THE DEPENDENCE OF SHEAR-STRESS AND CURRENT-DENSITY ON TEMPERATURE AND FIELD FOR A MODEL ELECTRORHEOLOGICAL FLUID
    PIALET, JW
    CLARK, DR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 208 : 204 - POLY
  • [33] Effect of Fluid Shear Stress on Portal Vein Remodeling in a Rat Model of Portal Hypertension
    Wen, Bin
    Liang, Jian
    Deng, Xin
    Chen, Ran
    Peng, Peichun
    GASTROENTEROLOGY RESEARCH AND PRACTICE, 2015, 2015
  • [34] Shear stress analysis of a polypyrrole/clay nanocomposite-based electrorheological fluid
    Fang, Fei Fei
    Choi, Hyoung Jin
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2006, 12 (06) : 843 - 845
  • [35] Solder joints stress analysis and optimization of chip component under shear and tensile load based on orthogonal experimental design and gray correlation analysis
    Li, Shuyi
    Huang, Chunyue
    Liu, Xiaobin
    Wang, Gui
    Liang, Ying
    Gao, Chao
    Cao, Zhiqin
    MICROELECTRONICS RELIABILITY, 2024, 163
  • [36] Effect of Fluid Shear Stress on Migration of Vascular Smooth Muscle Cells in Cocultured Model
    Naoya Sakamoto
    Toshiro Ohashi
    Masaaki Sato
    Annals of Biomedical Engineering, 2006, 34
  • [37] Effect of fluid shear stress on migration of vascular smooth muscle cells in cocultured model
    Sakamoto, N
    Ohashi, T
    Sato, M
    ANNALS OF BIOMEDICAL ENGINEERING, 2006, 34 (03) : 408 - 415
  • [38] Hele Shaw microfluidic device: A new tool for systematic investigation into the effect of the fluid shear stress for organs-on-chips
    Delon, Ludivine C.
    Guo, Zhaobin
    Kashani, Moein Navvab
    Yang, Chih-Tsung
    Prestidge, Clive
    Thierry, Benjamin
    METHODSX, 2020, 7
  • [39] Constitutive model for shear yield stress of magnetorheological fluid based on the concept of state transition
    Varela-Jimenez, M. I.
    Vargas Luna, J. L.
    Cortes-Ramirez, J. A.
    Song, G.
    SMART MATERIALS AND STRUCTURES, 2015, 24 (04)
  • [40] Design of an in vitro microfluidic cell culture system to study aortic valve endothelial cells under shear stress
    Young, Edmond W. K.
    Wheeler, Aaron
    Simmons, Craig A.
    JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 2006, 40 (06) : 901 - 901