Design and analysis of microfluidic kidney-on-chip model: fluid shear stress based study with temperature effect

被引:11
|
作者
Sateesh, Jasti [1 ]
Guha, Koushik [1 ]
Dutta, Arindam [2 ]
Sengupta, Pratim [3 ]
Rao, K. Srinivasa [4 ]
机构
[1] Natl Inst Technol Silchar, Natl MEMS Design Ctr, Dept Elect & Commun Engn, Silchar 788010, Assam, India
[2] RG Stone Urol & Laparoscop Hosp, Kolkata, W Bengal, India
[3] Belle Vue Clin, Kolkata, W Bengal, India
[4] KLEF, MEMS Res Ctr, Dept Elect & Commun Engn, Guntur, Andhra Prades, India
关键词
COLLECTING DUCT; CELLS; DISEASE; FLOW;
D O I
10.1007/s00542-018-4261-z
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The flow in the nephron tubules regulates the blood homeostasis, secretion, excretion and reabsorption of solutes. Flow induces fluid shear stress (FSS) on walls of tubules which has substantial effect on kidney functioning. Modelling of FSS mimicking structures is critical for their optimization. In this paper, a compact structure for kidney-on-chip devices is proposed for exact reconstruction of FSS and temperature effect in tubules considering the nephron tubule dimensions for modelling. The proposed system is compartmentalized basically into three parts ultra filter, device structure and reactor. The FSS is analysed for different inflow rates, proving the proposed structure is helpful in balancing the tubuloglomerulo feedback system mimicking. The structure is analysed for different structural changes in benchmark FEM tool COMSOL Multiphysics to optimize it to suite the kidney-on-chip purpose. Pressure achieved at the cell site is 0.1 Pa, which is the pressure applied by FFS on kidney tubules cells. The temperature effect of the human body is considered and the findings are presented. Temperature has an inverse relationship with FSS. At absolute temperature the pressure is 9.7 Pa and reached 3.77 Pa at body temperature, showing a decrease in pressure. The reaction of sodium and calcium is presented to show common reabsorption happening the kidney. The fabrication process flow is implemented in Intellisuite tool which is incorporated here to indicate the device fabrication cost will be low. The proposed Kidney-on-Chip structure finds astounding results make it to use in potential transplantable devices.
引用
收藏
页码:2553 / 2560
页数:8
相关论文
共 50 条
  • [21] The effect of shear stress reduction on endothelial cells: A microfluidic study of the actin cytoskeleton
    Inglebert, Mehdi
    Locatelli, Laura
    Tsvirkun, Daria
    Sinha, Priti
    Maier, Jeanette A.
    Misbah, Chaouqi
    Bureau, Lionel
    BIOMICROFLUIDICS, 2020, 14 (02)
  • [22] Error Analysis and Optimization of Shear Yield Stress Model for Magnetorheological Fluid
    Li, Hao-peng
    Chen, Fei
    Liu, Cheng-hao
    Tian, Zu-zhi
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2019, 44 (09) : 7779 - 7787
  • [23] Error Analysis and Optimization of Shear Yield Stress Model for Magnetorheological Fluid
    Hao-peng Li
    Fei Chen
    Cheng-hao Liu
    Zu-zhi Tian
    Arabian Journal for Science and Engineering, 2019, 44 : 7779 - 7787
  • [24] The effect of shear stress on cell docking inside microfluidic systems: Computational and experimental analysis
    Cioffi, M.
    Moretti, M.
    Manbachi, A.
    Chung, B. G.
    Khademhosseini, A.
    Dubini, G.
    TISSUE ENGINEERING PART A, 2008, 14 (05) : 914 - 914
  • [25] PID Temperature Control System-Based Microfluidic PCR Chip for Genetic Analysis
    Kim, Hyo Eun
    Schuck, Ariadna
    Kim, Won-Young
    Jung, Eun Kyo
    Hong, Yong-Hoo
    Kim, Yong-Sang
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2022, 17 (01) : 495 - 501
  • [26] PID Temperature Control System-Based Microfluidic PCR Chip for Genetic Analysis
    Hyo Eun Kim
    Ariadna Schuck
    Won-Young Kim
    Eun Kyo Jung
    Yong-Hoo Hong
    Yong-Sang Kim
    Journal of Electrical Engineering & Technology, 2022, 17 : 495 - 501
  • [27] Circular-shaped microfluidic device to study the effect of shear stress on cellular orientation
    Park, Da Yeon
    Kim, Tae Hyeon
    Lee, Jong Min
    Ahrberg, Christian D.
    Chung, Bong Geun
    ELECTROPHORESIS, 2018, 39 (14) : 1816 - 1820
  • [28] Shear stress analysis of phosphorylated potato starch based electrorheological fluid
    Hong, Cheng Hai
    Choi, Hyoung Jin
    KOREA-AUSTRALIA RHEOLOGY JOURNAL, 2007, 19 (04) : 221 - 225
  • [29] Design and Analysis of Particulate Matter Air-Microfluidic Grading Chip Based on MEMS
    Chen, Tingting
    Sun, Jianhai
    Ma, Tianjun
    Li, Tong
    Liu, Chang
    Zhu, Xiaofeng
    Xue, Ning
    MICROMACHINES, 2019, 10 (08)
  • [30] Shear stress analysis of a semiconducting polymer based electrorheological fluid system
    Cho, MS
    Choi, HJ
    Jhon, MS
    POLYMER, 2005, 46 (25) : 11484 - 11488