Study of stability after low voltage ride-through caused by phase-locked loop of grid-side converter

被引:13
|
作者
Zhang, Ziqian [1 ]
Schuerhuber, Robert [1 ]
Fickert, Lothar [1 ]
Friedl, Katrin [1 ]
机构
[1] Inffeldgasse 18, A-8010 Graz, Austria
关键词
Grid-side converter; Phase-locked loop; Low voltage ride-through; Stability; PLL; INSTABILITY; SYSTEMS;
D O I
10.1016/j.ijepes.2021.106765
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In a power system with a high percentage of converter coupled generation, dynamic characteristics of the converter affects the stability of the whole power system. The interaction of the various control loops of the gridside converter, e.g., the phase-locked loop and the DC link voltage control loop, dominates the various dynamic characteristics of the grid-side converter, including its low voltage ride-through ability. In this paper, the phaselocked loop is modeled and analyzed and a stability criterion for the converter, depending on the grid impedance, is obtained. According to this criterion, a common low voltage ride-through test device based on the shunt impedance voltage sag generator is analyzed. The results show that, and explain why, the test device cannot reproduce the characteristics of the practical grid, which is also verified by experiments using a controllerHardware-in-the-loop system.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] High voltage ride-through capability using series grid side converter for doubly fed induction generator based wind turbines
    Boukhris, Youness
    El Makrini, Aboubakr
    El Moussaoui, Hassan
    El Markhi, Hassane
    PROCEEDINGS OF 2015 3RD IEEE INTERNATIONAL RENEWABLE AND SUSTAINABLE ENERGY CONFERENCE (IRSEC'15), 2015, : 766 - 771
  • [42] A Phase-Locked Loop Based Technique for Accurate Estimation of Grid Voltage Fundamental Parameters
    Kamruzzaman, S. M.
    Sarker, Ausmita
    Ghosh, Rahul
    Reza, Md. Shamim
    2016 9TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (ICECE), 2016, : 385 - 388
  • [43] Control Strategy of Low Voltage Ride-Through for Grid-Connected Photovoltaic Inverter
    Zhang, Peng
    Zhang, Guorong
    Wang, Haining
    2015 IEEE 6TH INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS (PEDG), 2015, : 639 - 644
  • [44] Improving low voltage ride-through capabilities for grid connected wind turbine generator
    Mali, Shrikant
    James, Steffy
    Tank, Ishwari
    4 INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY RESEARCH (ICAER 2013), 2014, 54 : 530 - 540
  • [45] Improvement Low-Voltage Ride-Through Control of DFIG During Grid Faults
    Riouch, Tariq
    El-Bachtiri, Rachid
    2014 INTERNATIONAL CONFERENCE ON MULTIMEDIA COMPUTING AND SYSTEMS (ICMCS), 2014, : 1596 - 1601
  • [46] Stability Analysis and Nonlinear Control of Phase Locked Loop of a Weak-grid Connected Voltage Source Converter
    Mansour, Milad Zarif
    Hadavi, Sajjad
    Bahrani, Behrooz
    2020 FIFTEENTH INTERNATIONAL CONFERENCE ON ECOLOGICAL VEHICLES AND RENEWABLE ENERGIES (EVER), 2020,
  • [47] The Influence of Phase-Locked Loop on the Stability of Single-Phase Grid-Connected Inverter
    Zhang, Chong
    Wang, Xiongfei
    Blaabjerg, Frede
    Wang, Weisheng
    Liu, Chun
    2015 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2015, : 4737 - 4744
  • [48] Modeling and Stability Analysis of the Phase-locked Loop for Single Phase Grid-tied Inverter
    Qian, Qiang
    Xu, Jinming
    Bian, Shengyiyang
    Ni, Zhaohui
    Xie, Shaojun
    2018 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2018, : 3103 - 3107
  • [49] Frequency-to-voltage converter based dual-loop phase-locked loop with variable phase locking capability
    Saifullah, Z. M.
    Furth, Paul M.
    Pakala, SriHarsh
    Roman-Loera, Alejandro
    ELECTRONICS LETTERS, 2022, 58 (25) : 943 - 945
  • [50] Power-Angle Synchronization for Grid-Connected Converter With Fault Ride-Through Capability for Low-Voltage Grids
    Mukherjee, Subhajyoti
    Chowdhury, Vikram Roy
    Shamsi, Pourya
    Ferdowsi, Mehdi
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2018, 33 (03) : 970 - 979