Study of stability after low voltage ride-through caused by phase-locked loop of grid-side converter

被引:13
|
作者
Zhang, Ziqian [1 ]
Schuerhuber, Robert [1 ]
Fickert, Lothar [1 ]
Friedl, Katrin [1 ]
机构
[1] Inffeldgasse 18, A-8010 Graz, Austria
关键词
Grid-side converter; Phase-locked loop; Low voltage ride-through; Stability; PLL; INSTABILITY; SYSTEMS;
D O I
10.1016/j.ijepes.2021.106765
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In a power system with a high percentage of converter coupled generation, dynamic characteristics of the converter affects the stability of the whole power system. The interaction of the various control loops of the gridside converter, e.g., the phase-locked loop and the DC link voltage control loop, dominates the various dynamic characteristics of the grid-side converter, including its low voltage ride-through ability. In this paper, the phaselocked loop is modeled and analyzed and a stability criterion for the converter, depending on the grid impedance, is obtained. According to this criterion, a common low voltage ride-through test device based on the shunt impedance voltage sag generator is analyzed. The results show that, and explain why, the test device cannot reproduce the characteristics of the practical grid, which is also verified by experiments using a controllerHardware-in-the-loop system.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Transient Stability Impact of the Phase-Locked Loop on Grid-Connected Voltage Source Converters
    Wu, Heng
    Wang, Xiongfei
    2018 INTERNATIONAL POWER ELECTRONICS CONFERENCE (IPEC-NIIGATA 2018 -ECCE ASIA), 2018, : 2673 - 2680
  • [22] Stator Voltage Sensorless DFIG With Low Voltage Ride-Through Capability Using Series and Parallel Grid Side Converters
    Omar, Sh.
    Helal, A.
    Elarabawy, I.
    2016 7TH INTERNATIONAL RENEWABLE ENERGY CONGRESS (IREC), 2016,
  • [23] Stability Control of Grid-Connected Converter Considering Phase-Locked Loop Frequency Coupling Effect
    Zhang, Ye
    Pen, Haibo
    Zhang, Xiaoyu
    ENERGIES, 2024, 17 (14)
  • [24] Evaluation of voltage sag ride-through of a doubly fed induction generator wind turbine with series grid side converter
    Flannery, P. S.
    Venkataramanan, G.
    2007 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, 2007, : 1839 - 1845
  • [25] Unbalanced Voltage Sag Ride-Through of A Doubly Fed Induction Generator Wind Turbine with Series Grid Side Converter
    Flannery, Patrick
    Venkataramanan, Giri
    2008 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, VOLS 1-5, 2008, : 556 - 563
  • [26] An Adaptive Phase-Locked Loop for the Transient Stability Enhancement of Grid-Connected Voltage Source Converters
    Wu, Heng
    Wang, Xiongfei
    2018 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2018, : 5892 - 5898
  • [27] Evaluation of Low Voltage Ride-Through Capability of Synchronous Generator Connected to a Grid
    Yang Shicong
    Shagar, G. Viknash
    Ukil, Abhisek
    Jayasinghe, S. D. Gamini
    Gupta, Amit K.
    2015 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2015,
  • [28] A grid-side fault ride-through method suitable for offshore wind farms connected with MMC-MTDC
    Jia K.
    Dong X.
    Li J.
    Li Y.
    Niu H.
    Bi T.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2023, 51 (21): : 76 - 85
  • [29] Low voltage ride-through feature in single phase two stage grid tied PV inverter
    Pirjada, Mahemudmiya
    Nizami, Najma S.
    Dhaneria, Asheesh
    Singh, Ashish
    10TH INTERNATIONAL CONFERENCE ON ELECTRONICS, COMPUTING AND COMMUNICATION TECHNOLOGIES, CONECCT 2024, 2024,
  • [30] Low-Voltage Ride-Through Algorithm for Grid-Forming Converters
    Fernandez, Juan Dolado
    Eloy-Garcia, Joaquin
    Navarro, Eduardo Rausell
    Gomez, Santiago Arnaltes
    Amenedo, Jose Luis Rodriguez
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2025, 40 (01) : 303 - 315