Study of stability after low voltage ride-through caused by phase-locked loop of grid-side converter

被引:13
|
作者
Zhang, Ziqian [1 ]
Schuerhuber, Robert [1 ]
Fickert, Lothar [1 ]
Friedl, Katrin [1 ]
机构
[1] Inffeldgasse 18, A-8010 Graz, Austria
关键词
Grid-side converter; Phase-locked loop; Low voltage ride-through; Stability; PLL; INSTABILITY; SYSTEMS;
D O I
10.1016/j.ijepes.2021.106765
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In a power system with a high percentage of converter coupled generation, dynamic characteristics of the converter affects the stability of the whole power system. The interaction of the various control loops of the gridside converter, e.g., the phase-locked loop and the DC link voltage control loop, dominates the various dynamic characteristics of the grid-side converter, including its low voltage ride-through ability. In this paper, the phaselocked loop is modeled and analyzed and a stability criterion for the converter, depending on the grid impedance, is obtained. According to this criterion, a common low voltage ride-through test device based on the shunt impedance voltage sag generator is analyzed. The results show that, and explain why, the test device cannot reproduce the characteristics of the practical grid, which is also verified by experiments using a controllerHardware-in-the-loop system.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] High Voltage Ride-through Control Strategy of Grid-side Converter for DFIG-based WECS
    Zheng, Zhong
    Yang, Geng
    Geng, Hua
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 5282 - 5287
  • [2] High Voltage Ride-Through of Grid-side Converter for PMSG Based Directly Driven Wind Turbines
    Liu Changxian
    He Jing
    Xie Zhen
    PROCEEDINGS OF THE 35TH CHINESE CONTROL CONFERENCE 2016, 2016, : 8528 - 8532
  • [3] A Phase-locked Loop Method for Low Voltage Ride-Through Control in Three-phase Three-wire Photovoltaic Grid System
    Ding, Bao
    Zhang, Gong
    Zhang, Yong-Ming
    Zhao, Liang
    AUTOMATIC CONTROL AND MECHATRONIC ENGINEERING II, 2013, 415 : 174 - 179
  • [4] A Novel Low Voltage Ride-Through Technique of Three-Phase Grid-Connected Inverters Based on a Nonlinear Phase-Locked Loop
    Sun, Guangyu
    Li, Yongli
    Jin, Wei
    Li, Song
    Gao, Yan
    IEEE ACCESS, 2019, 7 : 66609 - 66622
  • [5] Low voltage ride-through control of doubly-fed induction generator wind turbines with a series grid-side converter
    Yao, Jun
    Liao, Yong
    Li, Hui
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2010, 34 (06): : 98 - 103
  • [6] A mode switching based transient ride-through phase-locked loop
    Fan, Yiwen
    Han, Minxiao
    Zhang, Li
    Wang, Shuozhe
    Sun, Tiankui
    IET POWER ELECTRONICS, 2023, 16 (11) : 1879 - 1888
  • [7] A robust control scheme for grid-connected photovoltaic converters with low-voltage ride-through ability without phase-locked loop
    Sabir, Adeel
    Ibrir, Salim
    ISA TRANSACTIONS, 2020, 96 : 287 - 298
  • [8] Robust Stability of Grid-Connected Voltage Source Converter With Phase-Locked Loop
    Lu, Yiyuan
    Du, Zhengchun
    Li, Yujun
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2023, 38 (04) : 3981 - 3984
  • [9] Unbalanced Voltage Sag Ride-Through of a Doubly Fed Induction Generator Wind Turbine With Series Grid-Side Converter
    Flannery, Patrick S.
    Venkataramanan, Giri
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2009, 45 (05) : 1879 - 1887
  • [10] A Low-Voltage Ride-Through Method With Transformer Flux Compensation Capability of Renewable Power Grid-Side Converters
    Chou, Shih-Feng
    Lee, Chia-Tse
    Ko, Hsin-Cheng
    Cheng, Po-Tai
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (04) : 1710 - 1719