Evaluation of coronary arterial stenosis rate using simulated coronary arterial stenosis phantoms with retrospective ECG-gated reconstruction employing multi-slice (4-row) CT

被引:0
|
作者
Taniguchi, A
Jinzaki, M
Kuribayashi, S
Watanabe, N
Kataoka, T
Nobuta, Y
机构
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:193 / 193
页数:1
相关论文
共 30 条
  • [21] The accuracy of multislice spiral computed tomography using a novel ECG-Gated image reconstruction method for the assessment of coronary artery stenosis
    Horie, T
    Sato, Y
    Kato, M
    Inoue, F
    Imazeki, T
    Yoshimura, A
    Matsumoto, N
    Takahashi, M
    Kanmatsuse, K
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 421A - 421A
  • [22] Assessment of Myocardial Bridge and Mural Coronary Artery Using ECG-Gated 256-Slice CT Angiography: A Retrospective Study
    Ma, En-sen
    Ma, Guo-lin
    Yu, Hong-wei
    Wu, Wang
    Li, Kefeng
    SCIENTIFIC WORLD JOURNAL, 2013,
  • [23] Contrast-enhanced coronary artery visualization by electron beam tomography and retrospectively ECG-gated multi-slice spiral CT: a comparison of image quality
    Giesler, T
    Ropers, D
    Baum, U
    Ulzheimer, S
    Derlien, H
    Bautz, W
    Moshage, W
    Kalender, WA
    Daniel, WG
    Achenbach, S
    EUROPEAN HEART JOURNAL, 2001, 22 : 127 - 127
  • [24] Coronary Artery Stent Evaluation Using a Vascular Model at 64-Detector Row CT: Comparison between Prospective and Retrospective ECG-Gated Axial Scans
    Suzuki, Shigeru
    Furui, Shigeru
    Kuwahara, Sadatoshi
    Mehta, Dhruv
    Kaminaga, Tatsuro
    Miyazawa, Akiyoshi
    Ueno, Yasunari
    Konno, Kumiko
    KOREAN JOURNAL OF RADIOLOGY, 2009, 10 (03) : 217 - 226
  • [25] Coronary artery bypass grafts: ECG-gated multi-detector row CT angiography-influence of image reconstruction interval on graft visibility
    Willmann, JK
    Weishaupt, D
    Kobza, R
    Verdun, FR
    Seifert, B
    Marincek, B
    Boehm, T
    RADIOLOGY, 2004, 232 (02) : 568 - 577
  • [26] Efficacy of segmented ECG-gated reconstruction, which increases temporal resolution in multi-slice helical CT, in improving precision in volume analysis of the heart: Evaluation using a cardiac motion phantom
    Kobayashi, Y
    Tanaka, O
    Matsuura, K
    Hamada, K
    Hiraoka, M
    Imai, N
    RADIOLOGY, 2001, 221 : 161 - 161
  • [27] Efficacy of the ECG-gated reconstruction technique in 3D-CTA using multi-slice helical CT for the preoperative assessment of the ascending aorta in patients with aortic diseases
    Kobayashi, Y
    Tanaka, O
    Imai, N
    Adachi, H
    Hiraoka, M
    Taguchi, K
    RADIOLOGY, 2000, 217 : 134 - 135
  • [28] In vitro evaluation of metallic coronary artery stents with sub-millimeter multi-slice computed tomography using an ECG-gated cardiac phantom: Relationship between in-stent visualization and stent type
    Utsunomiya, Daisuke
    Awai, Kazuo
    Sakamoto, Takashi
    Hazeyama, Hiroyuki
    Nishiharu, Taiji
    Urata, Joji
    Yamashita, Yasuyuki
    CARDIOLOGY, 2007, 107 (04) : 254 - 260
  • [29] Comparison of transaxial source images and 3-plane, thin-slab maximal intensity projection images for the diagnosis of coronary artery stenosis with using ECG-gated cardiac CT
    Choi, JW
    Seo, JB
    Do, KH
    Choi, SI
    Lee, W
    Ko, SM
    Lee, SH
    Lee, JS
    Song, JW
    Song, KS
    Lim, TH
    KOREAN JOURNAL OF RADIOLOGY, 2006, 7 (01) : 20 - 27
  • [30] Simultated interexamination variability of Agatston score and 3D Ca-scoring methods using ECG gated multi-slice spiral CT for quantification of coronary calcium in asymptomatic high risk persons
    Fischbach, RM
    Fallenberg, EM
    Ohnesorge, BM
    Juergens, KU
    Assmann, G
    Heindel, WL
    RADIOLOGY, 2000, 217 : 589 - 590