Coronary artery bypass grafts: ECG-gated multi-detector row CT angiography-influence of image reconstruction interval on graft visibility

被引:24
|
作者
Willmann, JK
Weishaupt, D
Kobza, R
Verdun, FR
Seifert, B
Marincek, B
Boehm, T
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Clin Cardiol, CH-8091 Zurich, Switzerland
[3] Univ Lausanne, Inst Appl Radiophys, Lausanne, Switzerland
[4] Univ Zurich, Dept Biostat, Zurich, Switzerland
关键词
arteries; grafts and prostheses; computed tomography (CT); angiography; multidetector row; coronary angiography; coronary vessels; bypass graft;
D O I
10.1148/radiol.2322030788
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the influence of different reconstruction intervals of retrospectively electrocardiographically (ECG)-gated multi-detector row computed tomographic (CT) angiography on image quality of different segments of various types of coronary artery bypass grafts. MATERIALS AND METHODS: Twenty consecutive patients with 62 grafts underwent retrospectively ECG-gated four-channel multi-detector row CT angiography and conventional coronary angiography. Raw helical CT data were reconstructed at 0%-90% of the cardiac cycle in increments of 10%. Each graft was separated into three segments (proximal segment, graft body, and distal anastomosis). Three graft types were identified according to site of distal anastomosis. Two readers assessed image quality of segments and graft types. Effective radiation dose was calculated. RESULTS: Best image quality of all segments was obtained at a reconstruction interval of 500/6-70% of the cardiac cycle. Image quality of the proximal segment did not vary significantly with different reconstruction intervals (analysis of variance, P = .8), whereas image quality of the graft body and clistal anastomosis changed significantly with varying reconstruction intervals (P < .001). Distal anastomosis and body of types 1 and 2 grafts were best seen at 60%-70% of the cardiac cycle, whereas distal anastomosis and body of type 3 grafts were best visualized at 50%. Accuracy of CT angiography for detection of graft patency was 94% for reader I and 95% for reader 2. Effective dose for CT was 11.4 mSv for both men and women. Mean effective dose for angiography was 2.1 mSv for men and women. CONCLUSION: Optimal selection of reconstruction interval improves image quality of the graft body and of distal anastomosis in particular. (C) RSNA, 2004.
引用
收藏
页码:568 / 577
页数:10
相关论文
共 50 条
  • [1] Coronary arteries: Retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window
    Kopp, AF
    Schroeder, S
    Kuettner, A
    Heuschmid, M
    Georg, C
    Ohnesorge, B
    Kuzo, R
    Claussen, CD
    [J]. RADIOLOGY, 2001, 221 (03) : 683 - 688
  • [2] ECG-gated reconstructed multi-detector row CT coronary angiography:: Effect of varying trigger delay on image quality
    Hong, C
    Becker, CR
    Huber, A
    Schoepf, UJ
    Ohnesorge, B
    Knez, A
    Brüning, R
    Reiser, MF
    [J]. RADIOLOGY, 2001, 220 (03) : 712 - 717
  • [3] Coronary artery anomalies: Classification and ECG-gated multi-detector row CT findings with angiographic correlation
    Kim, So Yeon
    Seo, Joon Beom
    Do, Kyung-Hyun
    Heo, Jeong-Nam
    Lee, Jin Seong
    Song, Jae-Woo
    Choe, Yeon Hyeon
    Kim, Tae Hoon
    Yong, Hwan Seok
    Choi, Sang Il
    Song, Koun-Sik
    Lim, Tae-Hwan
    [J]. RADIOGRAPHICS, 2006, 26 (02) : 317 - U2
  • [4] Coronary artery anomalies: Classification and ECG-gated multi-detector row CT findings with angiographic correlation - Invited commentary
    White, Charles S.
    [J]. RADIOGRAPHICS, 2006, 26 (02) : 333 - 334
  • [5] Analysis of heart rate and its variation affecting image quality and optimized reconstruction window in retrospective ECG-gated coronary angiography using multi-detector row CT
    Lee, SH
    Choi, BW
    Kim, HJ
    Jung, H
    Son, HK
    Kang, WS
    Yoo, SK
    Choe, KO
    Yoo, HS
    [J]. 2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1622 - 1626
  • [6] Non-invasive assessment of coronary artery bypass graft with retrospectively ECG-gated four-row multi-detector spiral computed tomography
    Riccardo Marano
    Maria Luigia Storto
    Nicola Maddestra
    Lorenzo Bonomo
    [J]. European Radiology, 2004, 14 : 1353 - 1362
  • [7] Non-invasive assessment of coronary artery bypass graft with retrospectively ECG-gated four-row multi-detector spiral computed tomography
    Marano, R
    Storto, ML
    Maddestra, N
    Bonomo, L
    [J]. EUROPEAN RADIOLOGY, 2004, 14 (08) : 1353 - 1362
  • [8] Multi-detector row CT coronary angiography: Influence of reconstruction technique and heart rate on image quality
    Herzog, C
    Arning-Erb, M
    Zangos, S
    Eichler, K
    Hammerstingl, R
    Dogan, S
    Ackermann, H
    Vogl, TJ
    [J]. RADIOLOGY, 2006, 238 (01) : 75 - 86
  • [9] Segmentation of ECG-gated multi-detector row CT cardiac images for functional analysis
    Kim, JS
    Na, Y
    Bae, KT
    [J]. MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 1718 - 1726
  • [10] Evaluation of patency of coronary-artery bypass graft using multi-detector row CT
    Kim, M
    Choi, B
    Choi, DH
    Choe, KO
    Choi, H
    Kim, J
    [J]. RADIOLOGY, 2002, 225 : 390 - 390