Energy Sustainability and Management of Data Center

被引:0
|
作者
Wiboonrat, Montri [1 ]
机构
[1] Khon Kaen Univ, Coll Grad Study Management, Bangkok Campus, Bangkok, Thailand
关键词
data center; system reliability; zone protection; power distribution; energy sustainability;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The system reliability of Tier 4 or Class F4 or DC Category D can be derived by calculated probability density function (pdf), mean time between failures (MTBF), mean time to repair (MTTR), and failure rate (A) of component statistical reliability, from IEEE 493, to availability of data center. Since, data center standards, Uptime Tier Classification, TIA-942, BICSI 002, BITKOM, and EN 50600, are defined system reliability design through topology. Most of topology defines by a single line diagram of power distribution systems (PDS). The PDS design approach is using a coherent zone protection mechanism. This mechanism is tried to get rid of single point of failure by applying redundant topology N, N+l, 2N, and 2(N+1) through PDSs. This paper describes the zone protection approach of system reliability design for Tier 4 data centers. This paper was conducted design analysis of power distribution systems (PDS) from 8 (Tier 3) data centers and 2 (Tier 4) data centers while compared 5 data center standards subject to how to build the highest reliability of data center through zone protection as a recheck point. The results of paper analysis propose zonal survivability stages by applying a concept of mission critical load shedding (MCLS).
引用
收藏
页码:23 / 28
页数:6
相关论文
共 50 条
  • [41] A Joint Optimization Framework for Request Scheduling and Energy Storage Management in a Data Center
    Chen, Shuang
    Wang, Yanzhi
    Pedram, Massoud
    2015 IEEE 8TH INTERNATIONAL CONFERENCE ON CLOUD COMPUTING, 2015, : 163 - 170
  • [42] Power Modeling for Energy-Efficient Resource Management in a Cloud Data Center
    Anurina Tarafdar
    Soumi Sarkar
    Rajib K Das
    Sunirmal Khatua
    Journal of Grid Computing, 2023, 21
  • [43] Energy Management of Data Center and Prospect for Participation in Demand Side Resource Scheduling
    Gao C.
    Cao X.
    Yan H.
    Su W.
    Cao, Xiaojun (cxjcxj1992@163.com), 2017, Automation of Electric Power Systems Press (41): : 1 - 7
  • [44] DREAM: DistRibuted Energy-Aware traffic Management for Data Center Networks
    Zhou, Liang
    Bhuyan, Laxmi N.
    Ramakrishnan, K. K.
    E-ENERGY'19: PROCEEDINGS OF THE 10TH ACM INTERNATIONAL CONFERENCE ON FUTURE ENERGY SYSTEMS, 2019, : 273 - 284
  • [45] Energy, exergy and computing efficiency based data center workload and cooling management
    Gupta, Rohit
    Asgari, Sahar
    Moazamigoodarzi, Hosein
    Down, Douglas G.
    Puri, Ishwar K.
    APPLIED ENERGY, 2021, 299
  • [46] Data center energy efficiency
    Grbic, Aleksandar
    ABB Review, 2022, (03): : 40 - 45
  • [47] PERFORMANCE AND SUSTAINABILITY OF A MANAGEMENT MODEL FOR CIED WEB REMOTE CONTROL: DATA FROM A SINGLE TERTIARY CENTER
    Zoppo, F.
    Bacchiega, E.
    Brazzolotto, A.
    Carraro, C.
    Lago, L.
    Lupo, A.
    Mugnai, G.
    Piccoli, E.
    Zerbo, F.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2019, 21 (0E) : E112 - E112
  • [48] Energy Efficient Data Center
    Bieswanger, Andreas
    Hamann, Hendrik F.
    Wehle, Hans-Dieter
    IT-INFORMATION TECHNOLOGY, 2012, 54 (01): : 17 - 23
  • [49] Data Center Energy Metric
    Beaty, Donald L.
    ASHRAE JOURNAL, 2013, 55 (01) : 61 - 62
  • [50] Sustainability of Data Center Digital Twins with Reinforcement Learning
    Sarkar, Soumyendu
    Naug, Avisek
    Guillen, Antonio
    Luna, Ricardo
    Gundecha, Vineet
    Babu, Ashwin Ramesh
    Mousavi, Sajad
    THIRTY-EIGTH AAAI CONFERENCE ON ARTIFICIAL INTELLIGENCE, VOL 38 NO 21, 2024, : 23832 - 23834