The system reliability of Tier 4 or Class F4 or DC Category D can be derived by calculated probability density function (pdf), mean time between failures (MTBF), mean time to repair (MTTR), and failure rate (A) of component statistical reliability, from IEEE 493, to availability of data center. Since, data center standards, Uptime Tier Classification, TIA-942, BICSI 002, BITKOM, and EN 50600, are defined system reliability design through topology. Most of topology defines by a single line diagram of power distribution systems (PDS). The PDS design approach is using a coherent zone protection mechanism. This mechanism is tried to get rid of single point of failure by applying redundant topology N, N+l, 2N, and 2(N+1) through PDSs. This paper describes the zone protection approach of system reliability design for Tier 4 data centers. This paper was conducted design analysis of power distribution systems (PDS) from 8 (Tier 3) data centers and 2 (Tier 4) data centers while compared 5 data center standards subject to how to build the highest reliability of data center through zone protection as a recheck point. The results of paper analysis propose zonal survivability stages by applying a concept of mission critical load shedding (MCLS).
引用
收藏
页码:23 / 28
页数:6
相关论文
共 50 条
  • [31] Study on Data Center Optimal Management by utilizing Data Center Infrastructure Management
    Sasakura, Kosuke
    Aoki, Takeshi
    Watanabe, Takeshi
    2017 IEEE INTERNATIONAL TELECOMMUNICATIONS ENERGY CONFERENCE (INTELEC), 2017, : 604 - 608
  • [32] Energy in Africa Policy, Management and Sustainability
    Anand, Rashmi Rani
    INSIGHT ON AFRICA, 2020, 12 (02) : 194 - 198
  • [33] Robust optimal energy management of data center equipped with multi-energy conversion technologies
    Tian, Qiannan
    Guo, Qun
    Nojavan, Sayyad
    Sun, Xianke
    JOURNAL OF CLEANER PRODUCTION, 2021, 329
  • [34] ENERGY MANAGEMENT AND CONTROL STRATEGY FOR DC MICRO-GRID IN DATA CENTER
    Xu, Hui Guang
    He, Jun Ping
    Qin, Yi
    Li, Yang Hua
    2012 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2012,
  • [35] Implementing Data Center Network Energy Management Capabilities in NS3
    Sondur, Sanjeev
    Ray, Madhurima
    Biswas, Joyanta
    Kant, Krishna
    2017 EIGHTH INTERNATIONAL GREEN AND SUSTAINABLE COMPUTING CONFERENCE (IGSC), 2017,
  • [36] Ant Colony Optimization Algorithm to Dynamic Energy Management in Cloud Data Center
    Pang, Shanchen
    Zhang, Weiguang
    Ma, Tongmao
    Gao, Qian
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2017, 2017
  • [37] Evaluating the Upper Bound of Energy Cost Saving by Proactive Data Center Management
    Milocco, Ruben
    Minet, Pascale
    Renault, Eric
    Boumerdassi, Selma
    IEEE TRANSACTIONS ON NETWORK AND SERVICE MANAGEMENT, 2020, 17 (03): : 1527 - 1541
  • [38] Power Modeling for Energy-Efficient Resource Management in a Cloud Data Center
    Tarafdar, Anurina
    Sarkar, Soumi
    Das, Rajib K.
    Khatua, Sunirmal
    JOURNAL OF GRID COMPUTING, 2023, 21 (01)
  • [39] Investigation of air management and energy performance in a data center in Finland: Case study
    Lu, Tao
    Lu, Xiaoshu
    Remes, Matias
    Viljanen, Martti
    ENERGY AND BUILDINGS, 2011, 43 (12) : 3360 - 3372
  • [40] Review on Performance Metrics for Energy Efficiency in Data Center: The Role of Thermal Management
    Capozzoli, Alfonso
    Chinnici, Marta
    Perino, Marco
    Serale, Gianluca
    ENERGY EFFICIENT DATA CENTERS (E2DC 2014), 2015, 8945 : 135 - 151