Some geometrical and electrical aspects on the wire-to-cylinder corona discharge

被引:5
|
作者
Conesa, Antonio J. [1 ]
Sanchez, Mario [1 ]
Leon, Marina [1 ]
Cabrera, Angel [1 ]
机构
[1] INTA, Area Aerodinam Expt, Carretera Ajalvir,Km 4, Madrid 28850, Spain
关键词
CURRENT-VOLTAGE CHARACTERISTICS; MODEL; ENHANCEMENT; FLIGHT;
D O I
10.1016/j.elstat.2019.103355
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Corona discharge is a gas discharge that can be applied in a vast number of industrial applications. In all of them, knowing the current-voltage curves (CVCs) is of high importance because they determine the corona discharge operation range, from the inception voltage to the breakdown voltage. The CVCs are influenced by geometrical factors, ambient conditions and electrical parameters so the one only way to increase operation range without achieving spark voltage is lowering the inception voltage. Regarding geometrical parameters, it is widely known that reducing the distance between electrodes decreases the inception voltage, however two behaviours are found for the emitter radius in the literature. One of them establishes that there is a limit to the emitter size from which there is no change in the CVCs, while the another theory states that by reducing the emitter radius there is always an increase in the corona current. A series of measurements were carried-out for wire-to-cylinder corona discharge in parallel arrangement to study the influence of geometrical and electrical parameters over the current-voltage curves, mainly focusing in the wire radius. The results show that reducing the emitter radius always produces an increase in the corona discharge current. Although the inception voltage is generally higher for positive than for negative polarity, the experimental data suggest that there is an emitter radius from which this trend changes, being the negative inception voltage larger than for positive i.e. the inception voltage depends on the polarity of the discharge and the wire radius. Furthermore, the determination of the inception voltage by using four formulae is compared with the experimental data due to its importance to establish the operation range of corona devices. The influence of geometrical parameters is especially relevant to design and manufacture corona discharge devices e.g. low noise and without moving parts flying systems.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] The Current-Voltage Characteristics of Corona Discharge in Wire to Cylinder in Parallel Electrode Arrangement
    Conesa, Antonio J.
    Sanchez, Mario
    [J]. IEEE TRANSACTIONS ON PLASMA SCIENCE, 2018, 46 (08) : 3022 - 3030
  • [22] On the prediction of current-voltage characteristics for positive wire-to cylinder corona discharge
    Sanchez, Mario
    Conesa, Antonio J.
    [J]. JOURNAL OF ELECTROSTATICS, 2018, 96 : 23 - 29
  • [23] Influence of Magnetic Field on Characteristics of Corona Discharge in Wire-Cylinder Electrodes Configuration
    Wais, Sabah Ibrahim
    Mohammed, Pirzheen Ageed
    [J]. PLASMA, 2021, 4 (04) : 764 - 779
  • [24] Investigation on the Electrical Discharge Characteristics of a Unipolar Corona-Wire Aerosol Charger
    Intra, Panich
    Yawootti, Artit
    Vinitketkumnuen, Usanee
    Tippayawong, Nakorn
    [J]. JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2011, 6 (04) : 556 - 562
  • [25] Study of a new electrostatic precipitator with asymmetrical wire-to-cylinder configuration for cement particles collection
    Kherbouche, F.
    Benmimoun, Y.
    Tilmatine, A.
    Zouaghi, A.
    Zouzou, N.
    [J]. JOURNAL OF ELECTROSTATICS, 2016, 83 : 7 - 15
  • [26] Calculation of ozone generation by positive dc corona discharge in coaxial wire-cylinder reactors
    Yehia, Ashraf
    [J]. JOURNAL OF APPLIED PHYSICS, 2007, 101 (02)
  • [27] Regulation-controlling of boundary layer by multi-wire-to-cylinder negative corona discharge
    Wang, Wei
    Yang, Lanjun
    Wu, Kai
    Lin, Cen
    Huo, Peng
    Liu, Shuai
    Huang, Dong
    Lin, Mei
    [J]. APPLIED THERMAL ENGINEERING, 2017, 119 : 438 - 448
  • [28] Ionic wind generation by a wire-cylinder-plate corona discharge in air at atmospheric pressure
    Colas, Dorian F.
    Ferret, Antoine
    Pai, David Z.
    Lacoste, Deanna A.
    Laux, Christophe O.
    [J]. JOURNAL OF APPLIED PHYSICS, 2010, 108 (10)
  • [29] Calculation of ozone generation by positive dc corona discharge in coaxial wire-cylinder reactors
    Yehia, Ashraf
    [J]. Journal of Applied Physics, 2007, 101 (02):
  • [30] Characteristics of AC corona discharge pulses and RI levels in a coaxial wire-cylinder gap
    He, Wangling
    Wang, Yu
    Lan, Lei
    Wen, Xishan
    Wan, Baoquan
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,