Characteristics of AC corona discharge pulses and RI levels in a coaxial wire-cylinder gap

被引:0
|
作者
He, Wangling [1 ]
Wang, Yu [1 ]
Lan, Lei [1 ]
Wen, Xishan [1 ]
Wan, Baoquan [2 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan, Peoples R China
[2] China Elect Power Res Inst, State Key Lab Grid Environm Protect, Wuhan, Peoples R China
关键词
AC corona discharge; radio interference; current measurement;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
AC corona discharge characteristics and radio interference (RI) performances are studied by using a small corona cage with different applied AC voltages. Characteristic parameters of AC corona pulses are analyzed statistically, such as average amplitude and repetition frequency. Besides, RI levels generated by corona pulses are measured simultaneously. Then the relationship between current pulses and RI levels are discussed. It is found that, the measured quasi-peak RI current value lies between the peak and root-mean-square (RMS) current value calculated from the measured corona current pulse by using the frequency processing method, and there is an approximate linear relationship between RI level and product of positive pulses amplitude and square root of positive pulses frequency.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Characteristics of Alternating Current Corona Discharge Pulses and Its Radio Interference Level in a Coaxial Wire-Cylinder Gap
    He, Wangling
    Chen, Xiaoyue
    Wan, Baoquan
    Lan, Lei
    Fu, Wanzhang
    Guo, Haozhou
    Wen, Xishan
    [J]. IEEE TRANSACTIONS ON PLASMA SCIENCE, 2018, 46 (03) : 598 - 605
  • [2] The characteristics of negative corona discharge and radio interference at different altitudes based on coaxial wire-cylinder gap
    He, Wangling
    Wei, Hongyu
    Zhang, Yinlu
    Liu, Yongcong
    Liu, Yunpeng
    Wan, Baoquan
    Zhou, Yang
    Wang, Yanzhao
    Gan, Zheyuan
    [J]. PLASMA SCIENCE & TECHNOLOGY, 2024, 26 (02)
  • [3] The characteristics of negative corona discharge and radio interference at different altitudes based on coaxial wire-cylinder gap
    何旺龄
    魏宏宇
    张胤禄
    刘永聪
    刘云鹏
    万保权
    周阳
    王延召
    干喆渊
    [J]. Plasma Science and Technology, 2024, 26 (02) : 82 - 90
  • [4] Influence of AC Voltage on the Positive DC Corona Current Pulses in a Wire-cylinder Gap
    Wang, Zhenguo
    Lu, Tiebing
    Cui, Xiang
    Li, Xuebao
    Hiziroglu, Huseyin
    [J]. CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2016, 2 (04): : 58 - 65
  • [5] Experimental Study of the Corona Discharge in a Modified Coaxial Wire-Cylinder Electrostatic Precipitator
    Blejan, O.
    Notingher, P.
    Dumitran, L. M.
    Younes, M.
    Samuila, A.
    Dascalescu, L.
    [J]. CONFERENCE RECORD OF THE 2007 IEEE INDUSTRY APPLICATIONS CONFERENCE FORTY-SECOND IAS ANNUAL MEETING, VOLS. 1-5, 2007, : 1111 - +
  • [6] Experimental Study of the Corona Discharge in a Modified Coaxial Wire-Cylinder Electrostatic Precipitator
    Blejan, Octavian
    Notingher, Petru V.
    Dumitran, Laurentiu Marius
    Younes, Mohamed
    Samuila, Adrian
    Dascalescu, Lucian
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2010, 46 (01) : 3 - 8
  • [7] Measurement of positive direct current corona pulse in coaxial wire-cylinder gap
    Yin, Han
    Zhang, Bo
    He, Jinliang
    Wang, Wenzhuo
    [J]. PHYSICS OF PLASMAS, 2014, 21 (03)
  • [8] WIRE-CYLINDER CORONA DISCHARGE WITH THE WIRE AT POSITIVE POTENTIAL
    GOVINDARAJU, GR
    GURUMURTHY, GR
    [J]. INTERNATIONAL JOURNAL OF ELECTRONICS, 1979, 46 (05) : 497 - 506
  • [9] Calculation of ozone generation by positive dc corona discharge in coaxial wire-cylinder reactors
    Yehia, Ashraf
    [J]. Journal of Applied Physics, 2007, 101 (02):
  • [10] Calculation of ozone generation by positive dc corona discharge in coaxial wire-cylinder reactors
    Yehia, Ashraf
    [J]. JOURNAL OF APPLIED PHYSICS, 2007, 101 (02)