The importance of axial effects for borehole design of geothermal heat-pump systems

被引:89
|
作者
Marcotte, D. [1 ,2 ,3 ]
Pasquier, P. [3 ]
Sheriff, F. [2 ]
Bernier, M. [1 ]
机构
[1] Ecole Polytech, Dept Genies Civil Geol & Mines, Montreal, PQ H3C 3A7, Canada
[2] CANMET Energy Technol Ctr Varennes, Varennes, PQ J3X 1S6, Canada
[3] Golder Associates, Montreal, PQ H4N 2T2, Canada
关键词
Infinite line source; Finite line source; Ground loop heat exchangers; Hybrid systems; Underground water freezing;
D O I
10.1016/j.renene.2009.09.015
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper studies the effects of axial heat conduction in boreholes used in geothermal heat pump systems. The axial effects are examined by comparing the results obtained using the finite and infinite line source methods. Using various practical design problems, it is shown that axial effects are relatively important. Unsurprisingly, short boreholes and unbalanced yearly ground loads lead to stronger axial effects. In one example considered, it is shown that the borehole length is 15% shorter when axial conduction effects are considered. In another example dealing with underground water freezing, the amount of energy that has to be removed to freeze the ground is three times higher when axial effects are considered. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:763 / 770
页数:8
相关论文
共 50 条
  • [1] A review of methods to evaluate borehole thermal resistances in geothermal heat-pump systems
    Lamarche, Louis
    Kajl, Stanislaw
    Beauchamp, Benoit
    GEOTHERMICS, 2010, 39 (02) : 187 - 200
  • [2] DESIGN AND THEORETICAL ASPECTS OF HEAT-PUMP SYSTEMS
    DEVOTTA, S
    DIGGORY, PJ
    APPLIED ENERGY, 1982, 11 (02) : 125 - 150
  • [3] Computer simulation of borehole ground heat exchangers for geothermal heat pump systems
    Lee, C. K.
    Lam, H. N.
    RENEWABLE ENERGY, 2008, 33 (06) : 1286 - 1296
  • [4] Heat transfer in a geothermal heat-pump system - an analytical assessment
    Yang, Y.
    Datcheva, M.
    Koenig, D.
    Schanz, T.
    GEOTECHNIQUE LETTERS, 2014, 4 : 139 - 144
  • [5] HEAT-PUMP AND HEAT PIPE SYSTEMS
    VOGELSANG, H
    METALL, 1982, 36 (01): : 85 - 88
  • [6] Modelling of Thermal Behavior of Borehole Heat Exchangers of Geothermal Heat Pump Heating Systems
    Gornov, V. F.
    Peskov, N. V.
    Vasilyev, G. P.
    Kolesova, M. V.
    2016 3RD INTERNATIONAL CONFERENCE ON MECHANICS AND MECHATRONICS RESEARCH (ICMMR 2016), 2016, 77
  • [7] TRANSIENT ANALYSIS OF HEAT-PUMP ASSISTED DISTILLATION SYSTEMS .1. THE HEAT-PUMP
    SALIM, MA
    SADASIVAM, M
    BALAKRISHNAN, AR
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1991, 15 (02) : 123 - 135
  • [8] HEAT-PUMP DESIGN WITH THERMAL STORAGE
    HAVELSKY, V
    MECARIK, K
    HEAT RECOVERY SYSTEMS & CHP, 1989, 9 (05): : 447 - 450
  • [9] FINANCIAL ANALYSIS OF HEAT-PUMP SYSTEMS
    GLUCKMAN, R
    JOURNAL OF HEAT RECOVERY SYSTEMS, 1983, 3 (01): : 41 - 51
  • [10] THE COMPRESSION HEAT-PUMP, DESIGN OF A MODEL
    HAMAM, Y
    ROCARIES, F
    REVUE GENERALE DE THERMIQUE, 1983, 22 (263): : 747 - 757