The importance of axial effects for borehole design of geothermal heat-pump systems

被引:89
|
作者
Marcotte, D. [1 ,2 ,3 ]
Pasquier, P. [3 ]
Sheriff, F. [2 ]
Bernier, M. [1 ]
机构
[1] Ecole Polytech, Dept Genies Civil Geol & Mines, Montreal, PQ H3C 3A7, Canada
[2] CANMET Energy Technol Ctr Varennes, Varennes, PQ J3X 1S6, Canada
[3] Golder Associates, Montreal, PQ H4N 2T2, Canada
关键词
Infinite line source; Finite line source; Ground loop heat exchangers; Hybrid systems; Underground water freezing;
D O I
10.1016/j.renene.2009.09.015
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper studies the effects of axial heat conduction in boreholes used in geothermal heat pump systems. The axial effects are examined by comparing the results obtained using the finite and infinite line source methods. Using various practical design problems, it is shown that axial effects are relatively important. Unsurprisingly, short boreholes and unbalanced yearly ground loads lead to stronger axial effects. In one example considered, it is shown that the borehole length is 15% shorter when axial conduction effects are considered. In another example dealing with underground water freezing, the amount of energy that has to be removed to freeze the ground is three times higher when axial effects are considered. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:763 / 770
页数:8
相关论文
共 50 条