Comparison of the Effectiveness and Comfort Level of Two Commonly Used Mask Ventilation Techniques in a Model

被引:3
|
作者
Althunayyan, Saqer M. [1 ]
Alotaibi, Raied N. [2 ]
Aljanoubi, Mohammed A. [3 ]
Alharthi, Musab Z. [1 ]
Mubarak, Abdullah M. [2 ]
Al-Otaibi, Ahmed M. [4 ]
机构
[1] King Saud Univ, Prince Sultan Bin Abdulaziz Coll Emergency Med Se, Dept Accid & Trauma, Riyadh, Saudi Arabia
[2] King Saud Univ, Prince Sultan Bin Abdulaziz Coll Emergency Med Se, Dept Basic Sci, Mail Box 150019, Riyadh 11474, Saudi Arabia
[3] King Saud Univ, Prince Sultan Bin Abdulaziz Coll Emergency Med Se, Dept Aviat & Marines, Riyadh, Saudi Arabia
[4] King Saud Univ, Prince Sultan Bin Abdulaziz Coll Emergency Med Se, Dept Emergency Med Serv, Riyadh, Saudi Arabia
关键词
airway; ventilation; noninvasive ventilation; respiration; difficult mask ventilation; bag-valve-mask; operating room; PERFORMANCE; EFFICACY; HAND; BAG;
D O I
10.4187/respcare.07949
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Mask ventilation is an important rescue airway skill for providing oxygenation and ventilation. Maintaining a good face mask seal is a fundamental factor for successful ventilation. Therefore, the aim of this study was to compare the effectiveness and comfortability of 2 commonly used mask ventilation techniques. METHODS: A randomized crossover study was performed to compare the 2-handed C-E and 2-handed V-E techniques on a simulation model. Respiratory therapists were recruited by convenience sampling to hold the mask during mechanical ventilation with a fixed tidal volume (V-T) of 500 mL, a rate of 12 breaths/min and a PEEP of zero were provided. Each participant performed a 2-min ventilation session, with a total of 24 breaths for each technique. For each technique, we recorded the median V-T and the number of successful breaths (>= 300 mL). Provider comfort was assessed by using a 5-point Likert scale at the end of the 2 techniques. Subgroup analyses were conducted for sex, experience, and height of the participants. RESULTS: Of the 75 respiratory therapists recruited, 74 participants were included in the analysis. There was no statistically significant difference in the median V-T between the V-E (417 mL [interquartile range, 396-4271 mL) and C-E techniques (410 [interquartile range, 391-423] mL) (P = .82). Approximately 74% of breaths delivered by the C-E technique were effective, whereas only 68% of those delivered by the V-F technique were effective (P < .001). Must of the participants reported that using the 2-handed C-E technique was more comfortable. CONCLUSIONS: In our study, the median V-T did not differ significantly between the 2 techniques. However, the C-E technique seemed to be superior to the V-E technique in terms of the number of effectively delivered breaths and comfortability. Further studies are recommended for basic airway management techniques.
引用
收藏
页码:460 / 465
页数:6
相关论文
共 50 条
  • [31] The laryngeal mask airway: A comparison between two insertion techniques
    Wakeling, HG
    Butler, PJ
    Baxter, PJC
    ANESTHESIA AND ANALGESIA, 1997, 85 (03): : 687 - 690
  • [32] Comparison of two ventilation techniques during general anesthesia for extracorporeal shock wave lithotripsy: High-frequency jet ventilation versus spontaneous ventilation with a laryngeal mask airway
    Cormack, John R.
    Hui, Raymond
    Olive, David
    Said, Simone
    UROLOGY, 2007, 70 (01) : 7 - 10
  • [33] Comparison of the effectiveness of commonly used clinic-based treatments for external genital warts
    Sherrard, Jackie
    Riddell, Lynn
    INTERNATIONAL JOURNAL OF STD & AIDS, 2007, 18 (06) : 365 - 368
  • [34] ACTIVATED PARTIAL THROMBOPLASTIN TIME FOR AUTOMATED TECHNIQUES - A COMPARISON OF 2 COMMONLY USED REAGENTS
    CRAIG, S
    STEVENSON, KJ
    TABERNER, DA
    BRITISH JOURNAL OF BIOMEDICAL SCIENCE, 1994, 51 (04) : 321 - 327
  • [35] Comparison of three techniques of face mask ventilation in children less than two years of age-a randomized crossover study
    Jain, Divya
    Goel, Nitika
    Mehta, Swati
    Gandhi, Komal
    Parikh, Badal
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2019, 66 (08): : 999 - 1000
  • [36] COMPARISON OF COMMONLY APPLIED SOIL-GAS TECHNIQUES USED IN EVALUATING HYDROCARBON POTENTIAL
    RICHERS, DM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1984, 187 (APR): : 8 - GEOC
  • [37] Comparison of two commonly used methods in measurement of cancer volume in prostate biopsy
    Patel, Viharkumar
    Hubbard, Samuel
    Huang, Wei
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL PATHOLOGY, 2020, 13 (04): : 664 - +
  • [38] Laparoscopic adjustable gastric banding: A prospective comparison of two commonly used bands
    Ponson, AE
    Janssen, IMC
    Klinkenbijl, JHG
    OBESITY SURGERY, 2002, 12 (04) : 579 - 582
  • [39] Laparoscopic Adjustable Gastric Banding: A Prospective Comparison of Two Commonly Used Bands
    Alex E Ponson
    Ignace M C Janssen
    Jean H G Klinkenbijl
    Obesity Surgery, 2002, 12 : 579 - 582
  • [40] Comparison of ventilation techniques for compensation of mask leakage using a ventilator and a regular full-face mask: A bench study
    Liu, Shujie
    Dong, Ran
    Xiong, Siyi
    Shi, Jing-hui
    HELIYON, 2023, 9 (10)