Comparison of the Effectiveness and Comfort Level of Two Commonly Used Mask Ventilation Techniques in a Model

被引:3
|
作者
Althunayyan, Saqer M. [1 ]
Alotaibi, Raied N. [2 ]
Aljanoubi, Mohammed A. [3 ]
Alharthi, Musab Z. [1 ]
Mubarak, Abdullah M. [2 ]
Al-Otaibi, Ahmed M. [4 ]
机构
[1] King Saud Univ, Prince Sultan Bin Abdulaziz Coll Emergency Med Se, Dept Accid & Trauma, Riyadh, Saudi Arabia
[2] King Saud Univ, Prince Sultan Bin Abdulaziz Coll Emergency Med Se, Dept Basic Sci, Mail Box 150019, Riyadh 11474, Saudi Arabia
[3] King Saud Univ, Prince Sultan Bin Abdulaziz Coll Emergency Med Se, Dept Aviat & Marines, Riyadh, Saudi Arabia
[4] King Saud Univ, Prince Sultan Bin Abdulaziz Coll Emergency Med Se, Dept Emergency Med Serv, Riyadh, Saudi Arabia
关键词
airway; ventilation; noninvasive ventilation; respiration; difficult mask ventilation; bag-valve-mask; operating room; PERFORMANCE; EFFICACY; HAND; BAG;
D O I
10.4187/respcare.07949
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Mask ventilation is an important rescue airway skill for providing oxygenation and ventilation. Maintaining a good face mask seal is a fundamental factor for successful ventilation. Therefore, the aim of this study was to compare the effectiveness and comfortability of 2 commonly used mask ventilation techniques. METHODS: A randomized crossover study was performed to compare the 2-handed C-E and 2-handed V-E techniques on a simulation model. Respiratory therapists were recruited by convenience sampling to hold the mask during mechanical ventilation with a fixed tidal volume (V-T) of 500 mL, a rate of 12 breaths/min and a PEEP of zero were provided. Each participant performed a 2-min ventilation session, with a total of 24 breaths for each technique. For each technique, we recorded the median V-T and the number of successful breaths (>= 300 mL). Provider comfort was assessed by using a 5-point Likert scale at the end of the 2 techniques. Subgroup analyses were conducted for sex, experience, and height of the participants. RESULTS: Of the 75 respiratory therapists recruited, 74 participants were included in the analysis. There was no statistically significant difference in the median V-T between the V-E (417 mL [interquartile range, 396-4271 mL) and C-E techniques (410 [interquartile range, 391-423] mL) (P = .82). Approximately 74% of breaths delivered by the C-E technique were effective, whereas only 68% of those delivered by the V-F technique were effective (P < .001). Must of the participants reported that using the 2-handed C-E technique was more comfortable. CONCLUSIONS: In our study, the median V-T did not differ significantly between the 2 techniques. However, the C-E technique seemed to be superior to the V-E technique in terms of the number of effectively delivered breaths and comfortability. Further studies are recommended for basic airway management techniques.
引用
收藏
页码:460 / 465
页数:6
相关论文
共 50 条
  • [11] Conceptual comparison of two commonly used safeguarding principles
    Knegtering, B
    Brombacher, A
    COMPUTER SAFETY, RELIABILITY AND SECURITY, 1998, 1516 : 359 - 368
  • [12] Comparison of Two Commonly Used Metabolic Measurement Systems
    Little, Anna K.
    An, Hyun-Sung
    Byun, Wonwoo
    Lee, Jung-Min
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 758 - 758
  • [13] A comparison of two commonly used methods of weight estimation
    Argall, JAW
    Wright, N
    Mackway-Jones, K
    Jackson, R
    ARCHIVES OF DISEASE IN CHILDHOOD, 2003, 88 (09) : 789 - 790
  • [14] A comparison of commonly used and novel electronic techniques for evaluating cattle temperament
    Schwartzkopf-Genswein, K. S.
    Shah, M. A.
    Church, J. S.
    Haley, D. B.
    Janzen, K.
    Truong, G.
    Atkins, R. P.
    Crowe, T. G.
    CANADIAN JOURNAL OF ANIMAL SCIENCE, 2012, 92 (01) : 21 - 31
  • [15] Comparison of two commonly used methods for stimulating T cells
    Juanjuan Jiao
    Xincheng Zhao
    Ruixia Hou
    Ying Wang
    Wenjuan Chang
    Nannan Liang
    Yanmin Liu
    Jianxiao Xing
    Yue Cao
    Xiaofang Li
    Kaiming Zhang
    Biotechnology Letters, 2019, 41 : 1361 - 1371
  • [16] Comparison of two commonly used methods for stimulating T cells
    Jiao, Juanjuan
    Zhao, Xincheng
    Hou, Ruixia
    Wang, Ying
    Chang, Wenjuan
    Liang, Nannan
    Liu, Yanmin
    Xing, Jianxiao
    Cao, Yue
    Li, Xiaofang
    Zhang, Kaiming
    BIOTECHNOLOGY LETTERS, 2019, 41 (12) : 1361 - 1371
  • [17] Metabolic syndrome: Comparison of the two commonly used animal models
    Oron-Herman, Mor
    Kamari, Yehuda
    Grossman, Ehud
    Yeger, Gill
    Peleg, Edna
    Shabtay, Zehava
    Shamiss, Arie
    Sharabi, Yehonatan
    AMERICAN JOURNAL OF HYPERTENSION, 2008, 21 (09) : 1018 - 1022
  • [18] Comparison of interpolation techniques used in Bioclimatic comfort maps and approach developed through Raster calculation model
    Caglak, Savas
    MODELING EARTH SYSTEMS AND ENVIRONMENT, 2024, 10 (01) : 799 - 808
  • [19] Comparison of interpolation techniques used in Bioclimatic comfort maps and approach developed through Raster calculation model
    Savaş ÇAĞLAK
    Modeling Earth Systems and Environment, 2024, 10 : 799 - 808
  • [20] Comparison of four ventilation tubes commonly used in the pediatric population: A retrospective cohort study
    Morrissette, Margareta
    Ben-Dov, Tom
    Santacatterina, Michele
    Cathain, Eadaoin O.
    April, Max M.
    LARYNGOSCOPE INVESTIGATIVE OTOLARYNGOLOGY, 2024, 9 (04):