Reduction of fluoroscopy duration in radiofrequency ablation obtained by the use of a non-fluoroscopic catheter navigation system

被引:14
|
作者
Kesek, Milos [1 ]
Wallenius, Niklas
Ronn, Folke
Hoglund, Niklas
Jensen, Steen
机构
[1] Umea Univ Hosp, Ctr Heart, Dept Cardiol, S-90185 Umea, Sweden
[2] Umea Univ Hosp, Ctr Heart, Dept Clin Physiol, S-90185 Umea, Sweden
来源
EUROPACE | 2006年 / 8卷 / 12期
关键词
radiofrequency ablation; non-fluoroscopic mapping system; radiation exposure;
D O I
10.1093/europace/eul127
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Radiofrequency (RF) ablation requires placement of several catheters at critical positions. The catheters are positioned with fluoroscopy, resulting in a significant radiation exposure. We have investigated to what degree an intracardiac navigation system reduces the fluoroscopy duration in different groups of routine RF ablations. Methods and results The fluoroscopy time was evaluated in 365 consecutive routine RF ablations, performed between 2002 and 2005. An intracardiac navigation system (LocaLisa, Medtronic) was used from 2003. The data were prospectively entered into a database and subsequently retrieved, and the procedures classified as being performed with fluoroscopy only or with the aid of the LocaLisa system. After introduction of the LocaLisa system, the median fluoroscopy time decreased from 24 to 10 min in the 141 atrioventricular nodal re-entry tachycardia (AVNRT) ablations and from 43 to 28 min in the 71 atrial flutter (AR) ablations (P < 0.005 for both). In the 145 Wotff-Parkinson-White (WPW) ablations, a decrease from 27 to 23 min was observed (P = 0.03). The decrease in AVNRT and AFI, but not in WPW was associated with the introduction of the LocaLisa system. Conclusion The use of the LocaLisa system during RF ablations significantly reduced the fluoroscopy time in AVNRT and AR ablations, by a median of 58% and 46%, respectively.
引用
收藏
页码:1027 / 1030
页数:4
相关论文
共 50 条
  • [41] The Accuracy and Clinical Applicability of a Sensor Based Electromagnetic Non-fluoroscopic Catheter Tracking System
    Yamada, Shinya
    Lo, Li-Wei
    Lin, Yenn-Jiang
    Chang, Shih-Lin
    Chung, Fa-Po
    Hu, Yu-Feng
    Tuan, Ta-Chuan
    Chao, Tze-Fan
    Liao, Jo-Nan
    Lin, Chin-Yu
    Chen, Shih-Ann
    KOREAN CIRCULATION JOURNAL, 2019, 49 (01) : 84 - 96
  • [42] Electra anatomical mapping and catheter ablation of human atrial flutter using a 3-dimensional non-fluoroscopic mapping system
    Nakagawa, H
    Shah, N
    Freihoff, F
    Scleinkofer, D
    Gonzalez, MD
    Arruda, MS
    Calame, JD
    Goudeau, MD
    Imai, S
    Otomo, K
    Jackman, WM
    CIRCULATION, 1997, 96 (08) : 1429 - 1429
  • [43] Non-fluoroscopic electrophysiological catheter mapping and ablation of atrial flutter after atrial repair for transposition of the great arteries
    Halimi, F
    Hidden-Lucet, F
    Tonet, J
    Villain, E
    Fontaine, G
    Frank, R
    EUROPEAN HEART JOURNAL, 2000, 21 : 437 - 437
  • [44] Reduction of fluoroscopy exposure and procedure duration during ablation of atrial fibrillation using a novel anatomical navigation system
    Rotter, M
    Takahashi, Y
    Sanders, P
    Haïssaguerre, M
    Jaïs, P
    Hsu, LF
    Sacher, F
    Pasquié, JL
    Clementy, J
    Hocini, M
    EUROPEAN HEART JOURNAL, 2005, 26 (14) : 1415 - 1421
  • [45] Comparison of Fluoroscopy Use Between Cryoballoon and Radiofrequency Catheter Ablation for Paroxysmal Atrial Fibrillation
    Niu, Guodong
    Qiao, Yu
    Tian, Yongbo
    Feng, Tianjie
    Yao, Yan
    Zhang, Shu
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (05) : 652 - 653
  • [46] High accuracy of radio frequency catheter ablations guided by non-fluoroscopic mapping system in the swine atrium
    Shpun, S
    Gepstein, L
    Hayam, G
    BenHaim, SA
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (02) : 2073 - 2073
  • [47] Reduction of radiation exposure time during catheter ablation with the use of pulsed fluoroscopy
    Scanavacca, M
    d'Avila, A
    Velarde, JL
    Reolao, JB
    Sosa, E
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1998, 63 (01) : 71 - 74
  • [48] Radiation Exposure Reduction During Catheter Ablation by Changing the Setting of Fluoroscopic System
    Hijioka, Naoko
    Kaneshiro, Takashi
    Matsumoto, Yoshiyuki
    Yamada, Shinya
    Kamioka, Masashi
    Suzuki, Hitoshi
    Ishida, Takafumi
    Takeishi, Yasuchika
    CIRCULATION, 2018, 138
  • [49] Impact of use of robotic catheter navigation on fluoroscopy exposure during atrial fibrillation ablation procedures
    Kamal, A.
    Cihak, R.
    Peichl, P.
    Wichterle, D.
    Kautzner, J.
    EUROPEAN HEART JOURNAL, 2009, 30 : 561 - 561
  • [50] Circumferential pulmonary vein ablation guided by real-time, three-dimensional non-fluoroscopic localization of the Lasso catheter
    Eckardt, L
    Kirchhof, P
    Loh, P
    Wasmer, K
    Ribbing, M
    Mönnig, G
    Breithardt, G
    EUROPEAN HEART JOURNAL, 2003, 24 : 597 - 597