Aims Radiofrequency (RF) ablation requires placement of several catheters at critical positions. The catheters are positioned with fluoroscopy, resulting in a significant radiation exposure. We have investigated to what degree an intracardiac navigation system reduces the fluoroscopy duration in different groups of routine RF ablations. Methods and results The fluoroscopy time was evaluated in 365 consecutive routine RF ablations, performed between 2002 and 2005. An intracardiac navigation system (LocaLisa, Medtronic) was used from 2003. The data were prospectively entered into a database and subsequently retrieved, and the procedures classified as being performed with fluoroscopy only or with the aid of the LocaLisa system. After introduction of the LocaLisa system, the median fluoroscopy time decreased from 24 to 10 min in the 141 atrioventricular nodal re-entry tachycardia (AVNRT) ablations and from 43 to 28 min in the 71 atrial flutter (AR) ablations (P < 0.005 for both). In the 145 Wotff-Parkinson-White (WPW) ablations, a decrease from 27 to 23 min was observed (P = 0.03). The decrease in AVNRT and AFI, but not in WPW was associated with the introduction of the LocaLisa system. Conclusion The use of the LocaLisa system during RF ablations significantly reduced the fluoroscopy time in AVNRT and AR ablations, by a median of 58% and 46%, respectively.
引用
收藏
页码:1027 / 1030
页数:4
相关论文
共 50 条
  • [31] Value of the LocaLisa non-fluoroscopic mapping system in the ablation of atrial fibrillation
    Sanders, P.
    Jais, P.
    Hocini, M.
    Hsu, L. -F.
    Young, G. D.
    Scavee, C.
    Kuklik, P.
    Rotter, M.
    Takahashi, Y.
    Rostock, T.
    Sacher, F.
    John, B.
    Stiles, M.
    Haissaguerre, M.
    CARDIAC ARRHYTHMIAS 2005, 2005, : 205 - 211
  • [32] Microwave Catheter Navigation System for the Radiofrequency Liver Ablation
    Kollar, Jakub
    Drizdal, Tomas
    Vrba, Jan
    Vrba, David
    Pokorny, Tomas
    Novak, Marek
    Fiser, Ondrej
    CANCERS, 2022, 14 (21)
  • [33] Safety profile of near-zero fluoroscopy atrial fibrillation ablation with non-fluoroscopic catheter visualization: experience from 1000 consecutive procedures
    Weber, A.
    Bertagnolli, L.
    Rolf, S.
    Hindricks, G.
    Sommer, P.
    WIENER KLINISCHE WOCHENSCHRIFT, 2018, 130 : 84 - 84
  • [34] Contact Force-Sensing versus Standard Catheters in Non-Fluoroscopic Radiofrequency Catheter Ablation of Idiopathic Outflow Tract Ventricular Arrhythmias
    Karkowski, Grzegorz
    Kuniewicz, Marcin
    Zabek, Andrzej
    Kozluk, Edward
    Debski, Maciej
    Matusik, Pawel T.
    Lelakowski, Jacek
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (03)
  • [35] "Hands-Free" Non-Fluoroscopic Monitoring of Phrenic Nerve Function During Catheter Ablation
    MacVeigh, Theodore
    CIRCULATION, 2013, 128 (22)
  • [36] Catheter ablation of atrial fibrillation using a new non-fluoroscopic sensor-guided 3D navigation tool (MediGuide)
    Rolf, S.
    John, S.
    Gaspar, T.
    Sommer, P.
    Arya, A.
    Hindricks, G.
    Piorkowski, C.
    EUROPEAN HEART JOURNAL, 2011, 32 : 164 - 164
  • [37] Prototype of a fluoroscopic navigation system to guide the catheter ablation of cardiac arrhythmias
    Sierra, G
    LeBlanc, AR
    Leonard, M
    Nadeau, R
    Savard, P
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 138 - 141
  • [38] Use of a new non-fluoroscopic three-dimensional mapping system in type I atrial flutter ablation
    Verbeet, T
    Castro, J
    Morissens, M
    Ngoc, ET
    Decoodt, P
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 : S99 - S101
  • [39] Reducing radiation exposure during catheter ablation of supraventricular tachycardias with a new non-fluoroscopic imaging system - a single centre experience
    Kirchhof, P
    Loh, P
    Eckardt, L
    Ribbing, M
    Eick, O
    Breithardt, G
    Haverkamp, W
    EUROPEAN HEART JOURNAL, 2001, 22 : 691 - 691
  • [40] EXTENDED USE OF 3D NON-FLUOROSCOPIC MAPPING SYSTEMS TO REDUCE RADIATION EXPOSURE DURING CATHETER ABLATION PROCEDURES
    Del Greco, M.
    Marini, M.
    Coser, A.
    Ravanelli, D.
    Valentini, A.
    Bonmassari, R.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 : S50 - S50