Evaluation of image-guidance protocols in the treatment of head and neck cancers

被引:149
|
作者
Zeidan, Omar A. [1 ]
Langen, Katja M. [1 ]
Meeks, Sanford L. [1 ]
Manon, Rafael R. [1 ]
Wagner, Thomas H. [1 ]
Willoughby, Twyla R. [1 ]
Jenkins, D. Wayne [1 ]
Kupelian, Patrick A. [1 ]
机构
[1] MD Anderson Canc Ctr Orlando, Dept Radiat Phys, Orlando, FL 32806 USA
关键词
guidance; head-and-neck cancers; megavoltage CT; alignment protocols; TomoTherapy; LINEAR-ACCELERATOR; RADIATION-THERAPY; RADIOTHERAPY; SYSTEM; LOCALIZATION; ERRORS; UNIT; CT;
D O I
10.1016/j.ijrobp.2006.09.040
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The aim of this study was to assess the residual setup error of different image-guidance (IG) protocols in the alignment of patients with head and neck cancer. The protocols differ in the percentage of treatment fractions that are associated with image guidance. Using data from patients who were treated with daily IG, the residual setup errors for several different protocols are retrospectively calculated. Methods and Materials: Alignment data from 24 patients (802 fractions) treated with daily IG on a helical tomotherapy unit were analyzed. The difference between the daily setup correction and the setup correction that would have been made according to a specific protocol was used to calculate the residual setup errors for each protocol. Results: The different protocols are generally effective in reducing systematic setup errors. Random setup errors are generally not reduced for fractions that are not image guided. As a consequence, if every other treatment is image guided, still about 11% of all treatments (IG and not IG) are subject to three-dimensional setup errors of at least 5 mm. This frequency increases to about 29% if setup errors > 3 mm are scored. For various protocols that require 15% to 31% of the treatments to be image guided, from 50% to 60% and from 26% to 31% of all fractions are subject to setup errors > 3 mm and > 5 mm, respectively. Conclusion: Residual setup errors reduce with increasing frequency of IG during the course of external-beam radiotherapy for head-and-neck cancer patients. The inability to reduce random setup errors for fractions that are not image guided results in notable residual setup errors. (c) 2007 Elsevier Inc.
引用
收藏
页码:670 / 677
页数:8
相关论文
共 50 条
  • [1] Evaluation of image-guidance strategies in the treatment of head and neck cancers
    Zeidan, O. A.
    Langen, K.
    Meeks, S.
    Manon, R.
    Wagner, T.
    Willoughby, T.
    Jenkins, D.
    Kupelian, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S141 - S142
  • [2] The role of image-guidance systems for head and neck surgery
    Metson, R
    Cosenza, M
    Gliklich, RE
    Montgomery, WW
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1999, 125 (10) : 1100 - 1104
  • [3] Evaluation of image-guidance strategies in the treatment of localized prostate. cancers
    Lee, C.
    Kupelian, P.
    Langen, K.
    Zeidan, O.
    Meeks, S.
    MEDICAL PHYSICS, 2007, 34 (06) : 2380 - 2380
  • [4] Potential Utility of Image-guidance to Reduce PTV Margins for Patients Treated by IMRT for Head and Neck Cancer: Evaluation of Temporal-based Protocols
    Nandwani, P. K.
    Vyas, R.
    Mehta, M.
    Neema, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S105 - S106
  • [5] Evaluation of image-guidance strategies in the treatment of localized prostate cancer
    Kupelian, Patrick A.
    Lee, Choonik
    Langen, Katja M.
    Zeidan, Omar A.
    Mawn, Rafael R.
    Willoughby, Twyla R.
    Meeks, Sanford L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (04): : 1151 - 1157
  • [6] Quantification of Image-Guidance Benefit in Image-Guided Radiotherapy of Cancers
    Zhou, L.
    Deng, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3456 - 3456
  • [7] Quantification of Image-Guidance Benefit in Image-Guided Radiotherapy of Cancers
    Zhou, L.
    Deng, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E737 - E737
  • [8] Quantification of Image-Guidance Benefit in Image-Guided Radiotherapy of Cancers
    Zhou, L.
    Deng, J.
    MEDICAL PHYSICS, 2019, 46 (06) : E572 - E572
  • [9] CTV Guidance for Head and Neck Cancers
    Beadle, Beth M.
    Anderson, Carryn M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 100 (04): : 903 - 905
  • [10] Evaluation of Image-guidance Strategies for Prostate Cancer
    Piotrowski, T.
    Kaczmarek, K.
    Bajon, T.
    Ryczkowski, A.
    Jodda, A.
    Kazmierska, J.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2014, 13 (06) : 583 - 591