Evaluation of Image-guidance Strategies for Prostate Cancer

被引:2
|
作者
Piotrowski, T. [1 ,2 ]
Kaczmarek, K. [3 ]
Bajon, T. [3 ]
Ryczkowski, A. [2 ]
Jodda, A. [2 ]
Kazmierska, J. [1 ,3 ]
机构
[1] Univ Med Sci, Dept Electroradiol, Poznan, Poland
[2] Greater Poland Canc Ctr, Dept Med Phys, Poznan, Poland
[3] Greater Poland Canc Ctr, Dept Radiotherapy 2, Poznan, Poland
关键词
Helical tomotherapy; Image guided radiation therapy; Margins; Megavoltage CT; Cone beam CT; Prostate cancer; COMPUTED-TOMOGRAPHY; BONY ANATOMY; RADIOTHERAPY; CT; REGISTRATION; TOMOTHERAPY; SCHEDULE; MOTION; ESTRO; IMRT;
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
In this study, set-up accuracy and time consumption of different image-guidance protocols used for prostate cancer patients were compared. Set-up corrections from 60 prostate cancer patients treated on helical tomotherapy (HT) were used to simulate four types of image-guidance protocols which were based on: (i) a limited number of imaging sessions (IG-1), (ii) reduced registration tasks during daily imaging (IG-2), or (iii) and (iv) mixed methods of imaging (IG-3, IG-4). Each protocol was evaluated for three referencing scenarios based on the first fraction, first three fractions and first five fractions. Residual set-up error, the difference between the average set-up correction and the actual correction required, was used to evaluate the accuracy of each protocol. The first five fractions referencing scenario provides the highest reduction of the margins for each image-guidance protocol evaluated in this study. The first type of protocol is the shortest way to the effective correction of the systematic component of set-up error. For the second type of the protocol, the control of the residual errors is better and, as a result, the reduction of the margins is more significant than that obtained for the first one. Moreover, the second type of the protocol provides the highest accuracy of delivered dose. The result obtained for the fourth type of protocol does not decrease the calculated margins or increase their accuracy in correspondence to the no image guidance scheme. The fourth type of the protocol is not recommended as a protocol to be used to increase the conformity of the dose. The choice of the rest protocols should be validated in the context of (i) institutional practice regarding patient set-up procedure and its time consumption, (ii) acceptable balance between the amount of the dose delivered to the organ at risk and the additional imaging dose and (iii) patient anatomical conditions.
引用
收藏
页码:583 / 591
页数:9
相关论文
共 50 条
  • [1] Evaluation of image-guidance strategies in the treatment of localized prostate cancer
    Kupelian, Patrick A.
    Lee, Choonik
    Langen, Katja M.
    Zeidan, Omar A.
    Mawn, Rafael R.
    Willoughby, Twyla R.
    Meeks, Sanford L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (04): : 1151 - 1157
  • [2] Evaluation of image-guidance strategies with helical tomotherapy for localised prostate cancer
    Yeung, Timothy P. C.
    Yartsev, Slav
    Rodrigues, George
    Bauman, Glenn
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2011, 55 (02) : 220 - 228
  • [3] Evaluation of image-guidance strategies in the treatment of localized prostate. cancers
    Lee, C.
    Kupelian, P.
    Langen, K.
    Zeidan, O.
    Meeks, S.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2380 - 2380
  • [4] Evaluation of image-guidance strategies in the treatment of head and neck cancers
    Zeidan, O. A.
    Langen, K.
    Meeks, S.
    Manon, R.
    Wagner, T.
    Willoughby, T.
    Jenkins, D.
    Kupelian, P.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S141 - S142
  • [5] Daily image-guidance in prostate cancer radiotherapy - implications for treatment margins
    Glowacki, G.
    Majewski, W.
    Wojcieszek, P.
    Tukiendorf, A.
    Bodusz, D.
    Wozniak, G.
    Miszczyk, L.
    [J]. NEOPLASMA, 2015, 62 (02) : 326 - 331
  • [6] Image-guidance strategies with integrated on-board MVCT
    Ruchala, K
    Olivera, G
    Lu, W
    Kapatoes, J
    Cravens, R
    Chapman, T
    Schnarr, E
    Theisen, T
    Mackie, T
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S227 - S228
  • [7] Proton therapy planning and image-guidance strategies within a randomized controlled trial for high-risk prostate cancer
    Tilbaek, Sofie
    Muren, Ludvig Paul
    Vestergaard, Anne
    Stolarczyk, Liliana
    Ronde, Heidi S.
    Johansen, Tanja S.
    Sondergaard, Jimmi
    HOyer, Morten
    Alsner, Jan
    Bentzen, Lise Norgaard
    Petersen, Stine Elleberg
    [J]. CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2023, 41
  • [8] Integration of KV Image-Guidance with Arc Therapy for Radiotherapy of the Prostate
    Moseley, D.
    Sharpe, M.
    Craig, T.
    Jaffray, D.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [9] Cone beam CT for daily image-guidance in prostate radiotherapy
    Wiltshire, K. L.
    White, E. A.
    Moseley, D. J.
    Jaffiray, D. A.
    Warde, P.
    Catton, C.
    [J]. EJC SUPPLEMENTS, 2005, 3 (02): : 235 - 235
  • [10] Online Image-Guidance for Prostate SBRT: Dosimetric Benefits and Margin Analysis
    Li, T.
    Yuan, L.
    Lee, W.
    Yin, F.
    Wu, Q. J.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3798 - 3798