Evaluation of image-guidance protocols in the treatment of head and neck cancers

被引:149
|
作者
Zeidan, Omar A. [1 ]
Langen, Katja M. [1 ]
Meeks, Sanford L. [1 ]
Manon, Rafael R. [1 ]
Wagner, Thomas H. [1 ]
Willoughby, Twyla R. [1 ]
Jenkins, D. Wayne [1 ]
Kupelian, Patrick A. [1 ]
机构
[1] MD Anderson Canc Ctr Orlando, Dept Radiat Phys, Orlando, FL 32806 USA
关键词
guidance; head-and-neck cancers; megavoltage CT; alignment protocols; TomoTherapy; LINEAR-ACCELERATOR; RADIATION-THERAPY; RADIOTHERAPY; SYSTEM; LOCALIZATION; ERRORS; UNIT; CT;
D O I
10.1016/j.ijrobp.2006.09.040
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The aim of this study was to assess the residual setup error of different image-guidance (IG) protocols in the alignment of patients with head and neck cancer. The protocols differ in the percentage of treatment fractions that are associated with image guidance. Using data from patients who were treated with daily IG, the residual setup errors for several different protocols are retrospectively calculated. Methods and Materials: Alignment data from 24 patients (802 fractions) treated with daily IG on a helical tomotherapy unit were analyzed. The difference between the daily setup correction and the setup correction that would have been made according to a specific protocol was used to calculate the residual setup errors for each protocol. Results: The different protocols are generally effective in reducing systematic setup errors. Random setup errors are generally not reduced for fractions that are not image guided. As a consequence, if every other treatment is image guided, still about 11% of all treatments (IG and not IG) are subject to three-dimensional setup errors of at least 5 mm. This frequency increases to about 29% if setup errors > 3 mm are scored. For various protocols that require 15% to 31% of the treatments to be image guided, from 50% to 60% and from 26% to 31% of all fractions are subject to setup errors > 3 mm and > 5 mm, respectively. Conclusion: Residual setup errors reduce with increasing frequency of IG during the course of external-beam radiotherapy for head-and-neck cancer patients. The inability to reduce random setup errors for fractions that are not image guided results in notable residual setup errors. (c) 2007 Elsevier Inc.
引用
收藏
页码:670 / 677
页数:8
相关论文
共 50 条
  • [42] Integrating image-guidance into the cardiac operating room
    Fosse, E
    Hol, PK
    Samset, E
    Elle, OJ
    Rotnes, JS
    Bjornstad, P
    Lundblad, R
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2000, 9 (06) : 403 - 409
  • [43] COMBINED MODALITIES IN THE TREATMENT OF HEAD AND NECK CANCERS
    AISNER, J
    HIPONIA, D
    CONLEY, B
    JACOBS, M
    GRAY, W
    BELANI, CP
    SEMINARS IN ONCOLOGY, 1995, 22 (03) : 28 - 34
  • [44] Advances in the systemic treatment of head and neck cancers
    Specenier, Pol
    Vermorken, Jan B.
    CURRENT OPINION IN ONCOLOGY, 2010, 22 (03) : 200 - 205
  • [45] METHOTREXATE TREATMENT OF ADVANCED HEAD AND NECK CANCERS - A DOSE-RESPONSE EVALUATION
    WOODS, RL
    FOX, RM
    TATTERSALL, MHN
    CANCER TREATMENT REPORTS, 1981, 65 : 155 - 159
  • [46] How did treatment affect body image in patients treated for Head and Neck Cancers?
    Fourati, N.
    Jribi, A.
    Dhouib, F.
    Nouri, O.
    Siala, W.
    Mnejja, W.
    Daoud, J.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S969 - S970
  • [47] Utility of Image-Guidance in Frontal Sinus Surgery
    Oakley, Gretchen M.
    Barham, Henry P.
    Harvey, Richard J.
    OTOLARYNGOLOGIC CLINICS OF NORTH AMERICA, 2016, 49 (04) : 975 - +
  • [48] Design and evaluation of an image-guidance system for robot-assisted radical prostatectomy
    Thompson, Stephen
    Penney, Graeme
    Billia, Michele
    Challacombe, Ben
    Hawkes, David
    Dasgupta, Prokar
    BJU INTERNATIONAL, 2013, 111 (07) : 1081 - 1090
  • [49] IMPLEMENTATION OF IMAGE-GUIDANCE TECHNIQUES IN RADIATION THERAPY
    Thomas, Michael
    Clark, Brenda
    Macpherson, Miller
    Montgomery, Lynn
    Gerig, Lee
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 693 - 701
  • [50] Indications for image-guidance in pediatric sinonasal surgery
    Parikh, Sanjay R.
    Cuellar, Hernando
    Sadoughi, Babalk
    Aroniadis, Olga
    Fried, Marvin P.
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2009, 73 (03) : 351 - 356