Evaluation of breakdown characteristics of oil-immersed transformers under non-standard lightning impulse waveforms - Definition of non-standard lightning impulse waveforms and insulation characteristics for waveforms including pulses

被引:29
|
作者
Okabe, Shigemitsu [1 ]
机构
[1] Tokyo Elect Power Co Ltd, High Voltage & Insulat Grp, R&D Ctr, Tsurumi Ku, Yokohama, Kanagawa 2308510, Japan
关键词
oil-immersed transformer; non-standard lightning impulse voltage waveform; dielectric breakdown voltage; partial discharge inception voltage; oil gap; turn-to-turn insulation model; section-to-section insulation model; lightning impulse; withstand voltage;
D O I
10.1109/TDEI.2007.302883
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To lower the insulation specifications (specifically, the lightning impulse withstand voltage) of oil-immersed transformers and thus cut the equipment cost while maintaining the high reliability in its insulation performance, it is necessary to grasp in an organized way the insulation characteristics under non-standard lightning impulse voltage waveforms that represent actual surge waveforms encountered in the field and compare them with the characteristics under the standard lightning impulse waveform quantitatively. As described in this paper, the first step in a series of study for the purpose above was taken by analyzing lightning surge waveforms and restriking surge waveforms such as disconnector switching surge waveforms at UHV, 500 kV, and 275 kV substations and identifying four typical non-standard lightning impulse waveforms with basic frequencies of 0.24 to 1.0 MHz. Then, two of these non-standard lightning impulse waveforms, the single-pulse waveform which is the most basic type and the waveform with a pulse in the crest and a subsequent flat section, were used to measure the breakdown voltage and the partial discharge inception voltage while changing the parameters, on three models that represent the insulation elements of windings of oil-immersed transformers. Then, the resultant average breakdown voltages were evaluated in terms of the overvoltage durations, leading to a result of formulating them in a unified way. In the tested range, the dielectric breakdown values under nonstandard lightning impulse waveforms were higher, marking 52% at the maximum, than those under standard lightning impulse waveforms in all the cases, suggesting a possibility of lowering the insulation specifications of an oil-immersed transformer.
引用
收藏
页码:146 / 155
页数:10
相关论文
共 50 条
  • [41] Insulation characteristics of CO2 gas for non-standard lightning impulse oscillations - Insulation characteristics under single-frequency oscillations from 1.3 to 4.0 MHz
    Tokyo Electric Power Company, 4-1, Egasaki-cho, Tsurumi-ku, Yokohama 230-8510
    不详
    IEEJ Trans. Power Energy, 2006, 1 (91-96+12):
  • [42] Electric stresses on transformer winding insulation under standard and non-standard impulse voltages
    Bhuyan, Kaveri
    Chatterjee, Saibal
    ELECTRIC POWER SYSTEMS RESEARCH, 2015, 123 : 40 - 47
  • [43] Study on Voltage-number Characteristics of Transformer Insulation under Transformer Invading Non-standard Lightning Impulses
    Sun, Potao
    Sima, Wenxia
    Yang, Ming
    Lan, Xing
    Wu, Jingyu
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (06) : 3582 - 3591
  • [44] A simulation of breakdown characteristics of suspension insulators under standard lightning impulse voltages
    Inthoulath, Khamphasith
    Banmongkol, Channarong
    TENCON 2014 - 2014 IEEE REGION 10 CONFERENCE, 2014,
  • [45] Effective model for prediction of impulse strength of oil-impregnated paper insulation under non-standard impulse voltages
    Kumar, JSS
    Usa, S
    Udayakumar, K
    Venkatesan, S
    2004 International Conference on Power System Technology - POWERCON, Vols 1 and 2, 2004, : 1619 - 1622
  • [46] Electric Stress Analysis of a Medium Voltage Cable Termination Subjected to Standard and Non-Standard Lightning Impulse Voltages
    Bhattacharyya, S.
    Chakraborty, A.
    Saha, B.
    Chatterjee, S.
    2016 INTERNATIONAL CONFERENCE ON INTELLIGENT CONTROL POWER AND INSTRUMENTATION (ICICPI), 2016, : 169 - 173
  • [47] Behavior of LN2/Paper Composite Insulating Material under AC, Standard and Non-standard Lightning Impulse Voltage
    Yuvarajan, M.
    Suresh, D.
    Udayakumar, K.
    Usa, S.
    Benseley, A.
    Lal, D. Mohan
    2008 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2008, : 482 - +
  • [48] Discharge characteristics of oil-pressboard insulation under impulse voltage waveforms with different parameters
    Wang, Zhe
    Zhang, Qiaogen
    Wang, Tonglei
    Li, Jinzhong
    Gaodianya Jishu/High Voltage Engineering, 2015, 41 (06): : 1974 - 1980
  • [49] Investigation on the Effect of Simulated Standard and Non -Standard Lightning Impulse Voltage on the Conventional Oil -Paper Insulation
    Ghosh, Pradipta
    Chakraborty, Biswajit
    Pradhan, Arpan Kumar
    Dalai, Sovan
    Chatterjee, Saibal
    2022 IEEE 6TH INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS, CATCON, 2022, : 263 - 267
  • [50] Breakdown Characteristics of Protrusion on HV Conductor in GIS Under Oscillating and Standard Lightning Impulse Voltages
    Zhang, Liang
    Liu, Zehui
    Han, Xutao
    Li, Junhao
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 550 - 553