In-situ monitoring techniques for membrane fouling and local filtration characteristics in hollow fiber membrane processes: A critical review

被引:69
|
作者
Li, Xianhui [1 ,3 ]
Mo, Yinghiu [1 ]
Li, Jianxin [1 ,2 ]
Guo, Wenshan [4 ]
Ngo, Huu Hao [4 ]
机构
[1] Tianjin Polytech Univ, Sch Mat Sci & Technol, State Key Lab Separat Membranes & Membrane Proc, Tianjin 300387, Peoples R China
[2] Tianjin Polytech Univ, Sch Environm & Chem Engn, Tianjin 300387, Peoples R China
[3] Technion Israel Inst Technol, Grand Water Res Inst, Wolfson Fac Chem Engn, Rabin Desalinat Lab, IL-32000 Haifa, Israel
[4] Univ Technol Sydney, Ctr Technol Water & Wastewater, Sch Civil & Environm Engn, Sydney, NSW 2007, Australia
关键词
In-situ monitoring techniques; Hollow fiber membrane; Micro- and ultra- filtration processes; Membrane fouling; Filtration hydrodynamics; CONSTANT-TEMPERATURE ANEMOMETRY; INTERNAL FILTRATION; NONINVASIVE OBSERVATION; DOUBLE-END; FLOW DISTRIBUTION; FLUX DISTRIBUTION; WATER TREATMENT; DIALYSATE FLOW; ULTRAFILTRATION; PRESSURE;
D O I
10.1016/j.memsci.2017.01.030
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Membrane fouling is the most serious challenge in the hollow fiber microfiltration (MF) and ultrafiltration (UM processes. A number of in-situ monitoring techniques including optical and non-optical probes have been developed so that membrane fouling is better understood and controlled. This will help advance the membrane technology. In addition, the local filtration hydrodynamics wield a great influence on the membrane fouling formation and system operation stability. State-of-the-art in-situ monitoring techniques for membrane fouling and local filtration characteristics in hollow fiber MF/UF processes are critically reviewed. The principles and applications of these techniques are addressed in order to assess their strengths. This study demonstrated that the real-time observation techniques mainly focus on idealized laboratory apparatus and little on commercial membrane modules. Consequently, more attention should be paid to the development of simple and effective methods or integrated detecting technology so as to satisfy the real status of hollow fiber filtration processes and the optimization of membrane module. On the basis of this review, future analyses considering practical requirements are suggested as R & D priorities.
引用
收藏
页码:187 / 200
页数:14
相关论文
共 50 条
  • [41] Fouling and Cleaning Characteristics of Ultrafiltration of Hydrophobic Dissolved Organic Matter by a Polyvinyl Chloride Hollow Fiber Membrane
    Guo, Xiaoyan
    Gao, Wei
    Li, Jihui
    Hu, Wanli
    WATER ENVIRONMENT RESEARCH, 2009, 81 (06) : 626 - 632
  • [42] Selective in-situ water removal by polybenzoxazole hollow fiber membrane for enhanced CO 2 methanation
    Kim, Eun-Young
    Hyeon, Myeong-Hun
    Hwang, Hyun Wook
    Lee, Ji Young
    Kim, Seok Ki
    Bae, Youn-Sang
    Moon, Su-Young
    CHEMICAL ENGINEERING JOURNAL, 2024, 487
  • [43] Review of Hollow Fiber (HF) Membrane Filtration Technology for the Treatment of Oily Wastewater: Applications and Challenges
    Hosseini, Mahsa Keyvan
    Liu, Lei
    Hosseini, Parisa Keyvan
    Bhattacharyya, Anisha
    Lee, Kenneth
    Miao, Jiahe
    Chen, Bing
    JOURNAL OF MARINE SCIENCE AND ENGINEERING, 2022, 10 (09)
  • [44] Preparation of polysulfone titanium di oxide mixed matrix hollow fiber membrane and elimination of long term fouling by in situ photoexcitation during filtration of phenolic compounds
    Mukherjee, Raka
    De, Sirshendu
    CHEMICAL ENGINEERING JOURNAL, 2016, 302 : 773 - 785
  • [45] Use of capacitive microsensors and ultrasonic time-domain reflectometry for in-situ quantification of concentration polarization and membrane fouling in pressure-driven membrane filtration
    Zhang, Zhongxia
    Bright, Victor M.
    Greenberg, Alan R.
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 117 (02) : 323 - 331
  • [46] A review on hollow fiber membrane module towards high separation efficiency: Process modeling in fouling perspective
    Xianhui Li
    Mohammad Younas
    Mashallah Rezakazemi
    Quang Viet Ly
    Jianxin Li
    Chinese Chemical Letters, 2022, 33 (08) : 3594 - 3602
  • [47] A novel porous-carbon-based hollow fiber membrane with electrochemical reduction mediated by in-situ hydroxyl radical generation for fouling control and water treatment
    Yang, Yue
    Qiao, Sen
    Zhou, Jiti
    Quan, Xie
    APPLIED CATALYSIS B-ENVIRONMENTAL, 2019, 255
  • [48] A review on hollow fiber membrane module towards high separation efficiency: Process modeling in fouling perspective
    Li, Xianhui
    Younas, Mohammad
    Rezakazemi, Mashallah
    Quang Viet Ly
    Li, Jianxin
    CHINESE CHEMICAL LETTERS, 2022, 33 (08) : 3594 - 3602
  • [49] Coupling of membrane filtration and advanced oxidation processes for removal of pharmaceutical residues: A critical review
    Ganiyu, Soliu O.
    van Hullebusch, Eric D.
    Cretin, Marc
    Esposito, Giovanni
    Oturan, Mehmet A.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2015, 156 : 891 - 914
  • [50] In-situ Monitoring of Internal Local Temperature and Voltage of Proton Exchange Membrane Fuel Cells
    Lee, Chi-Yuan
    Fan, Wei-Yuan
    Hsieh, Wei-Jung
    SENSORS, 2010, 10 (07) : 6395 - 6405