In-situ monitoring techniques for membrane fouling and local filtration characteristics in hollow fiber membrane processes: A critical review

被引:69
|
作者
Li, Xianhui [1 ,3 ]
Mo, Yinghiu [1 ]
Li, Jianxin [1 ,2 ]
Guo, Wenshan [4 ]
Ngo, Huu Hao [4 ]
机构
[1] Tianjin Polytech Univ, Sch Mat Sci & Technol, State Key Lab Separat Membranes & Membrane Proc, Tianjin 300387, Peoples R China
[2] Tianjin Polytech Univ, Sch Environm & Chem Engn, Tianjin 300387, Peoples R China
[3] Technion Israel Inst Technol, Grand Water Res Inst, Wolfson Fac Chem Engn, Rabin Desalinat Lab, IL-32000 Haifa, Israel
[4] Univ Technol Sydney, Ctr Technol Water & Wastewater, Sch Civil & Environm Engn, Sydney, NSW 2007, Australia
关键词
In-situ monitoring techniques; Hollow fiber membrane; Micro- and ultra- filtration processes; Membrane fouling; Filtration hydrodynamics; CONSTANT-TEMPERATURE ANEMOMETRY; INTERNAL FILTRATION; NONINVASIVE OBSERVATION; DOUBLE-END; FLOW DISTRIBUTION; FLUX DISTRIBUTION; WATER TREATMENT; DIALYSATE FLOW; ULTRAFILTRATION; PRESSURE;
D O I
10.1016/j.memsci.2017.01.030
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Membrane fouling is the most serious challenge in the hollow fiber microfiltration (MF) and ultrafiltration (UM processes. A number of in-situ monitoring techniques including optical and non-optical probes have been developed so that membrane fouling is better understood and controlled. This will help advance the membrane technology. In addition, the local filtration hydrodynamics wield a great influence on the membrane fouling formation and system operation stability. State-of-the-art in-situ monitoring techniques for membrane fouling and local filtration characteristics in hollow fiber MF/UF processes are critically reviewed. The principles and applications of these techniques are addressed in order to assess their strengths. This study demonstrated that the real-time observation techniques mainly focus on idealized laboratory apparatus and little on commercial membrane modules. Consequently, more attention should be paid to the development of simple and effective methods or integrated detecting technology so as to satisfy the real status of hollow fiber filtration processes and the optimization of membrane module. On the basis of this review, future analyses considering practical requirements are suggested as R & D priorities.
引用
收藏
页码:187 / 200
页数:14
相关论文
共 50 条
  • [31] In-situ monitoring and quantification of fouling development in membrane distillation by means of optical coherence tomography
    Bauer, Annika
    Wagner, Michael
    Saravia, Florencia
    Bartl, Sandra
    Hilgenfeldt, Verena
    Horn, Harald
    JOURNAL OF MEMBRANE SCIENCE, 2019, 577 : 145 - 152
  • [32] Filtration characteristics of hollow fiber microfiltration membranes used in a specific double membrane bioreactor
    Guenther, Jan
    Albasi, Claire
    Lafforgue, Christine
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2009, 48 (07) : 1255 - 1263
  • [33] Heterogeneous electro-Fenton catalytic FeOCl@NCNT/ceramic membrane filtration for in-situ membrane fouling control: Performance and mechanism
    Zhang, Zixin
    Huang, Guohe
    Li, Yongping
    Chen, Xiujuan
    Yao, Yao
    Zhang, Peng
    Ren, Shaojie
    Li, Mengna
    Luo, Yifei
    Chen, Ning
    Feng, Renfei
    SEPARATION AND PURIFICATION TECHNOLOGY, 2023, 316
  • [34] A filtration model for prediction of local flux distribution and optimization of submerged hollow fiber membrane module
    Li, Xianhui
    Li, Jianxin
    Wang, Hong
    Huang, Xiaoxu
    He, Benqiao
    Yao, Yonghong
    Wang, Jie
    Zhang, Hongwei
    Ngo, Huu Hao
    Guo, Wenshan
    AICHE JOURNAL, 2015, 61 (12) : 4377 - 4386
  • [35] 3D in-situ simulation and particle tracing of gas filtration process for ultrafine particles removal using a hollow fiber membrane
    Lin, Frank
    Chen, Pei-Chuan
    Huang, Tse-Chiang
    Lin, Geng-Sheng
    Tung, Kuo-Lun
    JOURNAL OF MEMBRANE SCIENCE, 2021, 632
  • [36] Coupling ferrate pretreatment and in-situ ozonation/ceramic membrane filtration for wastewater reclamation: Water quality and membrane fouling (vol 590, 117310, 2019)
    Liu, Jing
    He, Keyou
    Zhang, Jiaxing
    Li, Chengyue
    Zhang, Zhenghua
    JOURNAL OF MEMBRANE SCIENCE, 2020, 596
  • [37] A critical review of extracellular polymeric substances (EPSs) in membrane bioreactors: Characteristics, roles in membrane fouling and control strategies
    Lin, Hongjun
    Zhang, Meijia
    Wang, Fangyuan
    Meng, Fangang
    Liao, Bao-Qiang
    Hong, Huachang
    Chen, Jianrong
    Gao, Weijue
    JOURNAL OF MEMBRANE SCIENCE, 2014, 460 : 110 - 125
  • [38] Analysis of local fouling in a pilot-scale submerged hollow-fiber membrane system for drinking water treatment by membrane autopsy
    Lee, Mooseok
    Kim, Jeonghwan
    SEPARATION AND PURIFICATION TECHNOLOGY, 2012, 95 : 227 - 234
  • [39] Effect of axial variation of flux on filtration characteristics of hollow fiber membrane for drinking water treatment
    Korea Institute of Construction Technology, Gyeonggi-Do, 411-712, Korea, Republic of
    Water Sci. Technol. Water Supply, 2007, 4 (95-101):
  • [40] Filtration characteristics of hollow fiber microfiltration membranes used in membrane bioreactor for domestic wastewater treatment
    Shimizu, Y
    Okuno, Y
    Uryu, K
    Ohtsubo, S
    Watanabe, A
    WATER RESEARCH, 1996, 30 (10) : 2385 - 2392