Numerical investigation on stress intensity around Bone-Implant interface by 3-Dimensional FEA and experimental verification by optical technique

被引:12
|
作者
Dhatrak, Pankaj [1 ]
Shirsat, Uddhav [2 ]
Sumanth, S. [3 ]
Deshmukh, Vijay [4 ]
机构
[1] Dr Vishwanath Karad MIT WPU, MAEERS MIT, Sch Mech Engn, Pune 38, Maharashtra, India
[2] Bhivarabai Swanat Coll Engn & Researach, Dept Mech Engn, Pune 41, Maharashtra, India
[3] MA Rangoonwal Coll Dent Sci & Res Ctr, Dept Periodont, Pune 01, Maharashtra, India
[4] Int Clin Dent Res Org, Pune 38, Maharashtra, India
关键词
Cancellous bone; Dental Implant; FEA; Optical Technique; Photoelastic stress;
D O I
10.1016/j.matpr.2020.06.097
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The aim of the current study is to examine numerically the stress intensity along bone-implant interface for selected implant systems under occlusal load using finite element analysis (FEA) and confirming the result experimentally by optical technique. To see the biomechanical performance at bone-implant interface the five types of implant systems are chosen for the current study. A three-dimensional (3D) computer aided design (CAD) is prepared using CreO Parametric modeling software. A non-linear contact between implant and surrounding bone is defined to analyze the stress intensity in the cancellous bone under the applied load of 100 N axial directions, 40 N laterals (Bucco-lingual) direction and 100 N oblique at 45 degree to the longitudinal axis of implant. An experimental photoelastic technique (Optical technique) is used to predict the stress intensity in a cancellous bone near the bone-implant interface using Tardy's method of compensation. A homogeneous blend of Araldite and hardener material is used to prepare a photoelastic block model. The maximum value of stress intensity is noted in Type-I implant system at apical part of implant whereas minimum value was noted in Type-III implant systemunder lateral and oblique loads. Stress intensity in cancellous bone at the bone interface is found to be more significant to the applied oblique load. (C) 2020 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:35 / 41
页数:7
相关论文
共 50 条
  • [1] Three dimensional FEA on the minimum contact fraction of bone-implant interface
    Jang, KS
    Kim, YS
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 1191 - 1191
  • [2] Numerical and experimental investigation of bone-implant interfaces
    Simoes, J.A.
    Morais, A.
    Monteiro, J.
    Vaz, M.A.
    Taylor, M.
    2001, Elsevier Science Ltd (34)
  • [3] Experimental and numerical study of cemented bone-implant interface behaviour
    Kytyr, D.
    Doktor, T.
    Jirousek, O.
    Mal, P. Zla
    Pokorny, D.
    YOUTH SYMPOSIUM ON EXPERIMENTAL SOLID MECHANICS (YSESM 2010), 2010, : 151 - 154
  • [4] Experimental and numerical study of cemented bone-implant interface behaviour
    Kytyr, D.
    Doktor, T.
    Jirousek, O.
    Zlamal, P.
    Pokorny, D.
    FRATTURA ED INTEGRITA STRUTTURALE, 2011, (15): : 5 - 13
  • [5] Analysis of the porous bone-implant fixation - experimental verification of numerical model
    Berdychowski, Maciej
    Mielniczuk, Janusz
    XXII SLOVAK-POLISH SCIENTIFIC CONFERENCE ON MACHINE MODELLING AND SIMULATIONS 2017 (MMS 2017), 2018, 157
  • [6] Significance of Orthotropic Material Models to Predict Stress Around Bone-Implant Interface Using Numerical Simulation
    Pankaj Dhatrak
    Vedant Girme
    Uddhav Shirsat
    S. Sumanth
    Vijay Deshmukh
    BioNanoScience, 2019, 9 : 652 - 659
  • [7] Significance of Orthotropic Material Models to Predict Stress Around Bone-Implant Interface Using Numerical Simulation
    Dhatrak, Pankaj
    Girme, Vedant
    Shirsat, Uddhav
    Sumanth, S.
    Deshmukh, Vijay
    BIONANOSCIENCE, 2019, 9 (03) : 652 - 659
  • [8] Evaluate the effect of bone density variation on stress distribution at the bone-implant interface using numerical analysis
    Hindurao, Bhargav
    Gujare, Aditya
    Jadhav, Harshavardhan
    Dhatrak, Pankaj
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2024, 238 (05) : 463 - 470
  • [9] 3-DIMENSIONAL STRESS-DISTRIBUTION AROUND A DENTAL IMPLANT AT DIFFERENT STAGES OF INTERFACE DEVELOPMENT
    BORCHERS, L
    REICHART, P
    JOURNAL OF DENTAL RESEARCH, 1983, 62 (02) : 155 - 159
  • [10] Bone-Implant Interface with Simulated Insertion Stress Around an Immediately Loaded Dental Implant in the Anterior Maxilla: A Three-Dimensional Finite Element Analysis
    Lee, Joon-Seok
    Cho, In-Ho
    Kim, Yung-Soo
    Heo, Seong-Joo
    Kwon, Ho-Beom
    Lim, Young-Jun
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (02) : 295 - 302