Smaller Anterior Chamber Volume Is Associated With Higher Risk of Intraocular Pressure Elevation After Laser Peripheral Iridotomy: A 1-Year Follow-Up Study

被引:3
|
作者
Zhou, Rouxi [1 ]
Li, Fei [1 ]
Gao, Kai [1 ]
Zhang, Xiulan [1 ]
机构
[1] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangzhou 510060, Peoples R China
来源
ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY | 2021年 / 10卷 / 02期
关键词
anterior chamber volume; glaucoma; laser iridotomy;
D O I
10.1097/APO.0000000000000317
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study was to analyze the predictive value of swept-source optical coherence tomography (SS-OCT) derived anterior-segment volumetric parameters such as anterior chamber volume (ACV) in the long-term follow-up of primary angle closure disease (PACD). Design: Longitudinal observational study. Methods: In this single-center longitudinal observational study, PACD patients undergoing laser peripheral iridotomy (LPI) were recruited. Anterior segment images of the patients were captured using SS-OCT before LPI, and at 1 week, 1 month, 3 months, 6 months, and 1 year after LPI. Ninety eyes of 81 subjects were enrolled, and 72 eyes of 72 subjects finished the 1 year follow-up. Data of all the 81 subjects were included for analysis. Intraocular pressure (IOP) elevation was defined as IOP >21 mm Hg at any time point after LPI. The association between baseline trabecular-iris space area 750 mu m from scleral spur (TISA750), ACV and iris volume (IV), and IOP elevation were analyzed using logistic regression. Results: Eighty-one subjects were included, 59 were female, and 22 were male, with a mean age of 60.98 +/- 9.44 years. IOP elevation appeared in 14 eyes. Mean TISA750 was negatively associated with IOP elevation (OR = 0.94, P = 0.02). The correlation of TISA750 with IOP elevation varies across quadrants and there was only significant association in temporal TISA750 (OR - 0.98, P - 0.046), whereas in the other 3 quadrants, there was no significant association. Greater ACV was associated with lower risk of IOP elevation (OR = 0.80, P= 0.031), whereas IV was not associated with IOP elevation. Conclusions: ACV is a reliable and accurate predictor for the outcome of PACD. Due to its 3-dimensional nature, the robustness of ACV is greater than traditional angle width parameters such as TISA750.
引用
收藏
页码:188 / 191
页数:4
相关论文
共 50 条
  • [31] Tocilizumab in rheumatoid arthritis-associated peripheral ulcerative keratitis: A 1-year follow-up case report
    Huang, Jia
    Chen, Zhen
    Zhao, Like
    Cheng, Yongjing
    Gao, Ming
    Huang, Cibo
    Wang, Zheng
    Wang, Fang
    RHEUMATOLOGY & AUTOIMMUNITY, 2022, 2 (01): : 45 - 50
  • [32] 1-Year Follow-up Study of Endothelial Cell Density Loss after Penetrating Keratoplasty
    Draca, Natasa
    Covic, Ana
    Pauk, Maja
    Pasalic, Adis
    Dekaris, Iva
    COLLEGIUM ANTROPOLOGICUM, 2011, 35 : 11 - 14
  • [33] Macular edema after surgery to treat rhegmatogenous retinal detachment: 1-year follow-up, incidence, and associated risk factors
    Finger, Caroline Thais Machry
    Maliska, Gabriela
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2024, 87 (04)
  • [34] Chagas disease is associated with a poor outcome at 1-year follow-up after cardiac resynchronization therapy
    Santana Passos, Luiz Carlos
    Vieira de Melo, Rodrigo Morel
    Lira, NYasmin Menezes
    Cardoso de Oliveira, Talia Ferreira
    Trindade, Thiago
    Carvalho, William
    Fagundes, MAlexsandro
    REVISTA DA ASSOCIACAO MEDICA BRASILEIRA, 2019, 65 (11): : 1391 - 1396
  • [35] Patients at Greatest Risk of Missing Initial 1-Year Follow-Up After Pituitary Adenoma Resection
    Behzadi, Faraz
    Pickles, Andrew C.
    Ciecierska, Shiau-Sing
    Choe, Shawn
    Prabhu, Vikram C.
    V. Germanwala, Anand
    WORLD NEUROSURGERY, 2024, 189 : E1092 - E1097
  • [36] Dual chamber rate responsive pacing system driven by contractility:: Final assessment after 1-year follow-up
    Clémenty, J
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (11): : 2192 - 2197
  • [37] Association Between Imaging Follow Up and 1-Year Reintervention Risk After Peripheral Vascular Intervention for Claudicatio
    Romain, Gaelle
    Smolderen, Kim
    Cleman, Jacob
    Callegari, Santiago
    Rahman, Mufti
    Knight, Derek
    Mena-Hurtado, Carlos
    CIRCULATION, 2024, 150
  • [38] 1-year follow-up after radiofrequency tonsillotomy and laser tonsillotomy in children: a prospective, double-blind, clinical study
    Klaus Stelter
    Stephan Ihrler
    Vanessa Siedek
    Martin Patscheider
    Thomas Braun
    Georg Ledderose
    European Archives of Oto-Rhino-Laryngology, 2012, 269 : 679 - 684
  • [39] 1-year follow-up after radiofrequency tonsillotomy and laser tonsillotomy in children: a prospective, double-blind, clinical study
    Stelter, Klaus
    Ihrler, Stephan
    Siedek, Vanessa
    Patscheider, Martin
    Braun, Thomas
    Ledderose, Georg
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2012, 269 (02) : 679 - 684
  • [40] Tracking of 24-hour and casual blood pressure: a 1-year follow-up study in adolescents
    O'Sullivan, JJ
    Derrick, G
    Foxall, RJ
    JOURNAL OF HYPERTENSION, 2000, 18 (09) : 1193 - 1196