Dual chamber rate responsive pacing system driven by contractility:: Final assessment after 1-year follow-up

被引:20
|
作者
Clémenty, J [1 ]
机构
[1] Haut LEveque Hosp, F-33604 Bordeaux, France
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1998年 / 21卷 / 11期
关键词
DDDR pacing; peak endocardial acceleration; cardiac contractility; long-term data;
D O I
10.1111/j.1540-8159.1998.tb01151.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to assess the long-term performance of a new dual chamber rate responsive pacing system based on the dynamic measurement of the peak endocardial acceleration (PEA) index of cardiac contractility Seventy patients who participated in the Multicenter European Clinical Evaluation were studied I year after implantation by continuously recording the PEA and the heart rate (HR) during exercise stress testing and during 24 hours of usual activities. A complete examination of standard parameters was also performed to assess the pacing/sensing lead characteristics. Statistical comparisons were performed with the data recorded with the same protocol at 1 month after implant for each patient. A linear correlation coefficient was calculated between PEA and sinus rate when the patient showed predominant atrial tracked rhythm. There were no significant differences between PEA values measured at 1 month and 1 year (PEA = 0.41 +/- 0.26 g vs 0.45 +/- 0.29 g at rest and PEA = 1.63 +/- 0.77 g vs 1.72 +/- 0.83 g during peak exercise). The correlation coefficient remained stable (0.67 +/- 0.15 vs 0.65 +/- 0.14 during daily life and 0.74 +/- 0.14 vs 0.77 +/- 0.11 during exercise). The PEA signal detected by the sensor was reliable and stable. No long-term complications or adverse effects were observed and the lead performance was comparable to that of a standard lead.
引用
收藏
页码:2192 / 2197
页数:6
相关论文
共 50 条
  • [1] LATE FOLLOW-UP OF DUAL-CHAMBER RATE-ADAPTIVE PACING
    BENDITT, DG
    WILBERT, L
    HANSEN, R
    ALAGONA, P
    GREENAWALD, K
    GHALI, MGH
    WHEELAN, K
    STEINHAUS, D
    COLLINS, J
    FETTER, J
    LURIE, K
    REMOLE, S
    AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (08): : 714 - 719
  • [2] ACTOBAT: 1-year follow-up
    Paneth, N
    PEDIATRICS, 1997, 100 (05) : 903 - 903
  • [3] STREAM 1-year follow-up
    Taylor, Jennifer
    EUROPEAN HEART JOURNAL, 2014, 35 (03) : 134 - 134
  • [4] Lensectomy after radial keratotomy: 1-year follow-up
    José F. Alfonso
    Bárbara Martín-Escuer
    Alberto Domínguez-Vicent
    Robert Montés-Micó
    Luis Fernández-Vega
    International Ophthalmology, 2019, 39 : 2561 - 2568
  • [5] Lensectomy after radial keratotomy: 1-year follow-up
    Alfonso, Jose F.
    Martin-Escuer, Barbara
    Dominguez-Vicent, Alberto
    Montes-Mico, Robert
    Fernandez-Vega, Luis
    INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (11) : 2561 - 2568
  • [6] DUAL CHAMBER DDD PACING - INITIAL AND EARLY FOLLOW-UP ASSESSMENT, PROBLEMS, COMPLICATIONS, AND LIMITATIONS
    EASTWAY, RJ
    MALONEY, JD
    CASTLE, LW
    YIANNIKAS, J
    COOPER, J
    MORANT, VA
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1983, 6 (02): : 317 - 317
  • [7] Dual-chamber pacing in hypertrophic obstructive cardiomyopathy management: 10 year follow-up study
    Rasputnyak, O.
    Knyshov, G.
    Zalevskiy, V.
    Rudenko, K.
    Kravchuk, B.
    Beshlaga, V.
    Bilinskiy, Y.
    Zaharova, V.
    Kollakova, N.
    Punschikova, O.
    EUROPEAN HEART JOURNAL, 2010, 31 : 332 - 333
  • [8] POSTSCLEROTHERAPY HYPERPIGMENTATIONS - A 1-YEAR FOLLOW-UP
    GEORGIEV, M
    JOURNAL OF DERMATOLOGIC SURGERY AND ONCOLOGY, 1990, 16 (07): : 608 - 610
  • [9] Cognitive dysfunction after cardiac revascularization: follow-up at 1-year
    Madhavan, AK
    Wijemanne, I
    Zamvar, V
    Kulatilake, N
    Butchart, E
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2002, 84 (06) : 437 - 437
  • [10] 1-YEAR FOLLOW-UP OF CARDIAC STATUS AFTER ADRIAMYCIN THERAPY
    FRIEDMAN, MJ
    EWY, GA
    JONES, SE
    CRUZE, D
    MOON, TE
    CANCER TREATMENT REPORTS, 1979, 63 (11-1): : 1809 - 1816