Application of continuous-flow liquid phase microextraction to the analysis of phenolic compounds in wastewater samples

被引:22
|
作者
Chen, Xinmiao [1 ]
Zhang, Taozhi [1 ]
Liang, Pei [1 ]
Li, Yalan [1 ]
机构
[1] Cent China Normal Univ, Coll Chem, Wuhan 430079, Peoples R China
关键词
continuous-flow liquid-phase microextraction; wastewater analysis; phenols;
D O I
10.1007/s00604-006-0626-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method for the determination of phenolic compounds (phenol, o-cresol, m-cresol, 2,4-dimethylphenol, 2,3-dimethylphenol and 3,4-dimethylphenol) in water samples was developed by combined continuous-flow liquid-phase microextraction (CFME) with gas chromatography-flame ionization detection (GC-FID). The effects of extraction solvent type and volume, flow rate of sample solution, extraction time, salt concentration and pH on the extraction performance were investigated and optimized. The calibration curves and analyses of real samples were obtained under the following conditions: 3.0 mu L n-Amyl acetate, 1.5 mL min(-1) flowing rate, 15 min extracting time and pH 1.5. The developed protocol was found to yield a linear calibration curve in the concentration ranged from 10 to 10000 mu g L-1 for the target analytes, and the limits of detection ranged from 2.32 to 2.95 mu g L-1. Good repeatabilities of extraction were obtained, with relative standard deviation (R.S.D.) values below 6.89%. The results demonstrated that the CFME followed with GC-FID is a simple and reliable technique for the determination of phenolic compounds in water samples.
引用
收藏
页码:415 / 420
页数:6
相关论文
共 50 条
  • [31] LIQUID LIQUID EXTRACTION IN CONTINUOUS-FLOW SYSTEMS WITHOUT PHASE-SEPARATION
    CANETE, F
    RIOS, A
    DECASTRO, MDL
    VALCARCEL, M
    ANALYTICAL CHEMISTRY, 1988, 60 (21) : 2354 - 2357
  • [32] KINETICS OF MULTIPLE PHENOLIC-COMPOUNDS DEGRADATION WITH A MIXED CULTURE IN A CONTINUOUS-FLOW REACTOR
    BAE, B
    AUTENRIETH, RL
    BONNER, JS
    WATER ENVIRONMENT RESEARCH, 1995, 67 (02) : 215 - 223
  • [33] Application of Liquid-Liquid Microextraction-High-Performance Thin-Layer Chromatography for Preconcentration and Determination of Phenolic Compounds in Aqueous Samples
    Hakim Faraji
    Mohamad Saber-Tehrani
    Afshin Mirzaie
    Syed Waqif-Husain
    JPC – Journal of Planar Chromatography – Modern TLC, 2011, 24 : 214 - 217
  • [34] Application of Liquid-Liquid Microextraction-High-Performance Thin-Layer Chromatography for Preconcentration and Determination of Phenolic Compounds in Aqueous Samples
    Faraji, Hakim
    Saber-Tehrani, Mohamad
    Mirzaie, Afshin
    Waqif-Husain, Syed
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2011, 24 (03) : 214 - 217
  • [35] ORIGIN OF LAG PHASE OF CONTINUOUS-FLOW ANALYSIS CURVES
    THIERS, RE
    REED, AH
    DELANDER, K
    CLINICAL CHEMISTRY, 1971, 17 (01) : 42 - &
  • [36] Metagenomic Analysis of a Continuous-Flow Aerobic Granulation System for Wastewater Treatment
    Gomeiz, Alison T.
    Sun, Yewei
    Newborn, Aaron
    Wang, Zhi-Wu
    Angelotti, Bob
    Van Aken, Benoit
    MICROORGANISMS, 2023, 11 (09)
  • [37] Diazo Compounds in Continuous-Flow Technology
    Mueller, Simon T. R.
    Wirth, Thomas
    CHEMSUSCHEM, 2015, 8 (02) : 245 - 250
  • [38] The Generation of Diazo Compounds in Continuous-Flow
    Hock, Katharina J.
    Koenigs, Rene M.
    CHEMISTRY-A EUROPEAN JOURNAL, 2018, 24 (42) : 10571 - 10583
  • [39] CONTINUOUS-FLOW LIQUID-LIQUID-EXTRACTION - VARIABLES INFLUENCING PCB RECOVERY IN FIELD SAMPLES
    PEARSON, RF
    KING, PA
    HOLMES, MW
    EISENREICH, SJ
    SWACKHAMER, DL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 205 : 90 - ENVR
  • [40] A Headspace Cooled-liquid Phase Microextraction Technique and Its Application for Analysis of Fusel Oil in Water Samples and Volatile Compounds in Beer
    Chen Shi-Heng
    Wang Jian-Wei
    Li Wei-Wei
    Peng Hong
    Guan Ya-Feng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (05) : 675 - 679