Application of continuous-flow liquid phase microextraction to the analysis of phenolic compounds in wastewater samples

被引:22
|
作者
Chen, Xinmiao [1 ]
Zhang, Taozhi [1 ]
Liang, Pei [1 ]
Li, Yalan [1 ]
机构
[1] Cent China Normal Univ, Coll Chem, Wuhan 430079, Peoples R China
关键词
continuous-flow liquid-phase microextraction; wastewater analysis; phenols;
D O I
10.1007/s00604-006-0626-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method for the determination of phenolic compounds (phenol, o-cresol, m-cresol, 2,4-dimethylphenol, 2,3-dimethylphenol and 3,4-dimethylphenol) in water samples was developed by combined continuous-flow liquid-phase microextraction (CFME) with gas chromatography-flame ionization detection (GC-FID). The effects of extraction solvent type and volume, flow rate of sample solution, extraction time, salt concentration and pH on the extraction performance were investigated and optimized. The calibration curves and analyses of real samples were obtained under the following conditions: 3.0 mu L n-Amyl acetate, 1.5 mL min(-1) flowing rate, 15 min extracting time and pH 1.5. The developed protocol was found to yield a linear calibration curve in the concentration ranged from 10 to 10000 mu g L-1 for the target analytes, and the limits of detection ranged from 2.32 to 2.95 mu g L-1. Good repeatabilities of extraction were obtained, with relative standard deviation (R.S.D.) values below 6.89%. The results demonstrated that the CFME followed with GC-FID is a simple and reliable technique for the determination of phenolic compounds in water samples.
引用
收藏
页码:415 / 420
页数:6
相关论文
共 50 条
  • [21] APPLICATION OF CURVE REGENERATION TO CONTINUOUS-FLOW ANALYSIS
    WARD, RJ
    FENELAN, A
    PATHOLOGY, 1978, 10 (04) : 391 - 392
  • [22] Kinetics of multiple phenolic compounds degradation with a mixed culture in a continuous-flow reactor
    Department of Civil Engineering, Texas A and M University, College Station, TX 77843-3136, United States
    WATER ENVIRON. RES., 2 (215-223):
  • [23] APPLICATION OF CURVE REGENERATION TO CONTINUOUS-FLOW ANALYSIS
    DUECK, A
    CANADIAN JOURNAL OF MEDICAL TECHNOLOGY, 1975, 37 (01): : 1 - 13
  • [24] THE APPLICATION OF ELECTROANALYTICAL DETECTORS IN CONTINUOUS-FLOW ANALYSIS
    TOTH, K
    NAGY, G
    FEHER, Z
    HORVAI, G
    PUNGOR, E
    ANALYTICA CHIMICA ACTA, 1980, 114 (FEB) : 45 - 58
  • [25] Novel room temperature ionic liquid for phenolic compounds microextraction from environmental samples
    Huang, Fangzhi
    Berton, Paula
    Lu, Chengfei
    Siraj, Noureen
    Warner, Isiah M.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [26] Solid-phase microextraction coupled to high-performance liquid chromatography to determine phenolic compounds in water samples
    Penalver, A
    Pocurull, E
    Borrull, F
    Marcé, RM
    JOURNAL OF CHROMATOGRAPHY A, 2002, 953 (1-2) : 79 - 87
  • [27] Direct Immersion Single-Drop Microextraction and Continuous-Flow Microextraction for the Determination of Manganese in Tonic Drinks and Seafood Samples
    Nunes, Leane Santos
    das Gracas Andrade Korn, Maria
    Lemos, Valfredo Azevedo
    FOOD ANALYTICAL METHODS, 2020, 13 (08) : 1681 - 1689
  • [28] Application of liquid phase microextraction to forensic analysis
    He, Yi
    Locke, David C.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U295 - U296
  • [29] Direct Immersion Single-Drop Microextraction and Continuous-Flow Microextraction for the Determination of Manganese in Tonic Drinks and Seafood Samples
    Leane Santos Nunes
    Maria das Graças Andrade Korn
    Valfredo Azevedo Lemos
    Food Analytical Methods, 2020, 13 : 1681 - 1689
  • [30] AUTOMATED LOADING OF DISCRETE SAMPLES IN UNSEGMENTED CONTINUOUS-FLOW ANALYSIS
    STEWART, KK
    BEECHER, GR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1978, 176 (SEP): : 87 - 87