Can Peak-Picked ECG Be Used for Heart Rate Variability?

被引:0
|
作者
Gregg, Richard E. [1 ]
Firoozabadi, Reza [1 ]
Babaeizadeh, Saeed [1 ]
机构
[1] Philips Healthcare, Adv Algorithm Res Ctr, Andover, MA USA
关键词
ELECTROCARDIOGRAM;
D O I
10.22489/CinC.2018.181
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Use of peak-picked ECG is generally not recommended for heart rate variability (HRV) calculations because the apparent R-wave peak moves around within the QRS due to the peak-picking operation. This study tests an algorithm for recovering high resolution RR intervals from peak-picked ECG. Two databases were used for testing, simulated ECG and Holter ECG from end stage renal disease (ESRD) patients on and off hemodialysis. Twenty minute samples of single lead ECG (n=1000) were generated by the Physionet HRV ECG simulator. Each ECG record had a random combination of heart rate standard deviation and additive noise. 12-lead, 48 hour Holter ECG from 51 ESRD patients was split into 20 minute segments for HRV analysis. ECG was decimated to 250sps from 1000sps and then peak-picked to the final sample rate of 125sps. High resolution RR interval recovery was based on up-sampling and template matching to align beats. HRV standard deviation of RR intervals (SDNN) was calculated for each 20 min. segment. Bland-Altman analysis was used to assess bias of SDNN error across the SDNN range. The bias of SDNN error at low SDNN values was pronounced for RR intervals defined by R-wave peaks. RR correction by template matching reduced (1) the impact of noise and (2) the SDNN error at low levels of SDNN.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Robustness study of ECG biometric identification in heart rate variability conditions
    Pathoumvanh, Somsanouk
    Airphaiboon, Surapan
    Hamamoto, Kazuhiko
    [J]. IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2014, 9 (03) : 294 - 301
  • [32] Comparative Heart Rate Variability Analysis of ECG, Holter and PPG Signals
    Georgieva-Tsaneva, Galya N.
    Gospodinova, Evgeniya
    [J]. INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2021, 12 (12) : 464 - 470
  • [33] Detection of Heart Rate Variability From a Wearable Differential ECG Device
    Slak, Jure
    Kosec, Gregor
    [J]. 2016 39TH INTERNATIONAL CONVENTION ON INFORMATION AND COMMUNICATION TECHNOLOGY, ELECTRONICS AND MICROELECTRONICS (MIPRO), 2016, : 430 - 435
  • [34] Accuracy of the Minicardio system for heart rate variability analysis compared to ECG
    Cassirame, J.
    Stuckey, M. I.
    Sheppard, F.
    Tordi, N.
    [J]. JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2013, 53 (03): : 248 - 254
  • [35] Influence of Undetected ECG R waves on the Heart Rate Variability Analysis
    Naka, H.
    Tohara, T.
    Inoue, K.
    [J]. 2008 PROCEEDINGS OF SICE ANNUAL CONFERENCE, VOLS 1-7, 2008, : 3068 - 3072
  • [36] Effects of the ECG Sampling Frequency on the Multiscale Entropy of Heart Rate Variability
    Castiglioni, Paolo
    Faini, Andrea
    [J]. 2020 COMPUTING IN CARDIOLOGY, 2020,
  • [37] Usefulness of measurement of heart rate variability by holter ECG in hemodialysis patients
    Nanami Kida
    Yoshiharu Tsubakihara
    Hirota Kida
    Shunro Ageta
    Makoto Arai
    Yoshinosuke Hamada
    Nariaki Matsuura
    [J]. BMC Nephrology, 18
  • [38] HOLTER ECG MONITORING AND HEART RATE VARIABILITY IN BREAST CANCER PATIENTS
    Mehraliev, O. Sh
    [J]. WORLD OF MEDICINE AND BIOLOGY, 2021, 78 (04): : 105 - 110
  • [39] Heart rate variability, norepinephrine and ECG changes in subarachnoid hemorrhage patients
    Svigelj, V
    Grad, A
    Kiauta, T
    [J]. ACTA NEUROLOGICA SCANDINAVICA, 1996, 94 (02): : 120 - 126
  • [40] Nonlinear heart rate variability: A better ECG predictor of cardiovascular risk?
    Anderson, JL
    Horne, BD
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (01) : 21 - 23