Effective dose to staff from interventional procedures: estimations from single and double dosimetry

被引:14
|
作者
Kuipers, Gerritjan [1 ]
Velders, Xandra L. [1 ]
机构
[1] Acad Med Ctr, NL-1100 DD Amsterdam, Netherlands
关键词
CARDIAC-CATHETERIZATION; FOLLOW-UP; RADIOLOGY;
D O I
10.1093/rpd/ncp155
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The exposure of 11 physicians performing interventional procedures was measured by means of two personal dosemeters. One personal dosemeter was worn outside the lead apron and an additional under the lead apron. The study was set up in order to determine the added value of a dosemeter worn under the lead apron. With the doses measured, the effective doses of the physicians were estimated using an algorithm for single dosimetry and two algorithms for double dosimetry. The effective doses calculated with the single dosimetry algorithm ranged from 0.11 to 0.85 mSv in 4 weeks. With the double dosimetry algorithms, the effective doses ranged from 0.02 mSv to 0.47 mSv. The statistical analysis revealed no significant differences in the accuracy of the effective doses calculated with single or double dosimetry algorithms. It was concluded that the effective dose cannot be considered a more accurate estimate when two dosemeters are used instead of one.
引用
收藏
页码:95 / 100
页数:6
相关论文
共 50 条
  • [31] Staff and ambient radiation dose resulting from therapeutic nuclear medicine procedures
    Alkhorayef, M.
    Sulieman, A.
    Mohamed-Ahmed, M.
    Al-Mohammed, H. I.
    Alkhomashi, N.
    Sam, A. K.
    Bradley, D. A.
    APPLIED RADIATION AND ISOTOPES, 2018, 141 : 270 - 274
  • [32] Occupational radiation exposure in interventional cardiology: Assessing anesthesia staff 's skin dose with thermoluminescent dosimetry
    Ageel, Mohammed
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2024, 17 (02)
  • [33] Comparison of Five Developed Algorithms to Estimate Staff Effective Dose in Interventional Cardiology: Are They Interchangeable?
    Moladoust, Hassan
    Ghazanfari-Tehran, Maryam
    Nikseresht, Vahid
    Nadim, Tahereh
    Rad, Mohammad Assadian
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2015, 5 (03) : 647 - 651
  • [34] Exposure of cardiologists from interventional procedures
    Kuipers, Gerritjan
    Velders, Xandra L.
    Piek, Jan J.
    RADIATION PROTECTION DOSIMETRY, 2010, 140 (03) : 259 - 265
  • [35] Use of ultrasonographic guidance in interventional musculoskeletal procedures - A review from a single institution
    Sofka, CM
    Collins, AJ
    Adler, RS
    JOURNAL OF ULTRASOUND IN MEDICINE, 2001, 20 (01) : 21 - 26
  • [36] Estimating Effective Dose from Phantom Dose Measurements in Atrial Fibrillation Ablation Procedures
    Anderson-Evans, C.
    Wallace, T.
    Toncheva, G.
    Hranitzky, E.
    Hurwitz, L.
    Yoshizumi, T.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [37] Influence of standing positions and beam projections on effective dose and eye lens dose of anaesthetists in interventional procedures
    Kong, Y.
    Struelens, L.
    Vanhavere, F.
    Vargas, C. S.
    Schoonjans, W.
    Zhuo, W. H.
    RADIATION PROTECTION DOSIMETRY, 2015, 163 (02) : 181 - 187
  • [38] An investigation into patient and staff doses from X-ray angiography during coronary interventional procedures
    Morrish, W. E.
    Goldstone, K. E.
    BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (961): : 35 - 45
  • [39] Contemporary Interventional Radiology Dosimetry: Analysis of 4,784 Discrete Procedures at a Single Institution
    Bundy, Jacob J.
    Chick, Jeffrey Forris Beecham
    Hage, Anthony N.
    Gemmete, Joseph J.
    Srinivasa, Rajiv N.
    Johnson, Evan J.
    Christodoulou, Emmanuel
    Srinivasa, Ravi N.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2018, 15 (09) : 1214 - 1221
  • [40] Effective dose from diagnostic nuclear medicine procedures in northern Greece
    Hatziioannou, KA
    Hatzigiannaki, A
    MolyvdaAthanasopoulou, E
    Sioundas, A
    Kostaki, P
    Psarrakos, K
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 3, 1996, : C494 - C496