Comparative dosimetric analysis of whole abdominal radiotherapy with VMAT versus 3D conformal in patients with Wilms tumour

被引:1
|
作者
Olmos, Alejandro [1 ]
Rodriguez, Alejandro [1 ]
Beltran, Estefania [1 ]
Garay, Onix [1 ]
Felix, Armando [1 ]
Ponce, Mario Alberto [1 ]
Salcedo, Maurico [1 ]
Apresa, Teresa [1 ]
Lio, Lorena [1 ]
Guzman, Martha [1 ]
Chilaca, Fatima [1 ]
机构
[1] Mexican Social Secur Inst, Natl Med Ctr XXI Century, Oncol Hosp, Radiotherapy Dept, Mexico City, DF, Mexico
关键词
3D conformal radiotherapy; VMAT; Wilms tumour; whole abdomen radiotherapy; TRIAL; RISK;
D O I
10.1017/S1460396918000778
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction In this study, we undertake a dosimetric comparison of whole abdominal treatment plans of patients diagnosed with stage 3 Wilms tumour, to assess the benefits of treating these patients with volumetric arch therapy (VMAT) versus 3D conformal radiotherapy. Material and methods A retrospective study was undertaken on 23 patients receiving either VMAT or 3D conformal radiotherapy during 2013-2017. A dosimetric comparison was undertaken for both techniques, measuring planning target volume (PTV), conformity index (CI), homogeneity index (HI) and organs at risk (OAR). Results The dosimetric parameters for the PTV dose in the VMAT and 3D conformal technique showed no statistical difference (1,289 center dot 17 cGy versus 1,357 center dot 13 cGy, respectively, p=0 center dot 404). However, the VMAT technique had a better CI (1 center dot 04 VMAT versus 1 center dot 26 3D, p=0 center dot 004), and there was little difference in the HI (1 center dot 13 VMAT versus 1 center dot 15 3D, p=0 center dot 1606). In the statistical analysis, the decrease in dose to OAR for the VMAT technique is statistically significant for doses to lung and kidney (p=0 center dot 011 and p=0 center dot 002, respectively). Between the two techniques, there was no statistical significance in dose difference to the other OAR. Conclusion This work proposes using the VMAT technique in whole abdominal irradiation to improve conformity, without affecting the quality of the PTV coverage, when compared with the 3D conformal technique. In addition, VMAT reduces the doses to OAR such as the remaining kidney and lungs that are important to preserve to reduce the probability of radiation toxicity in these patients.
引用
收藏
页码:301 / 303
页数:3
相关论文
共 50 条
  • [21] IMPT IN ABDOMINAL NEUROBLASTOMA PATIENTS - A DOSIMETRY STUDY COMPARING IMPT WITH 3D CONFORMAL RADIOTHERAPY
    Eichholz, A.
    Rosenberg, I.
    Chang, Y. C.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S538 - S538
  • [22] Clinical outcome of postoperative highly conformal versus 3D conformal radiotherapy in patients with malignant pleural mesothelioma
    Jérôme Krayenbuehl
    Peter Dimmerling
    I Frank Ciernik
    Oliver Riesterer
    Radiation Oncology, 9
  • [23] Dosimetric end-to-end tests in a national audit of 3D conformal radiotherapy
    Lehmann, Joerg
    Alves, Andrew
    Dunn, Leon
    Shaw, Maddison
    Kenny, John
    Keehan, Stephanie
    Supple, Jeremy
    Gibbons, Francis
    Manktelow, Sophie
    Oliver, Chris
    Kron, Tomas
    Williams, Ivan
    Lye, Jessica
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2018, 6 : 5 - 11
  • [24] Clinical outcome of postoperative highly conformal versus 3D conformal radiotherapy in patients with malignant pleural mesothelioma
    Krayenbuehl, Jerome
    Dimmerling, Peter
    Ciernik, I. Frank
    Riesterer, Oliver
    RADIATION ONCOLOGY, 2014, 9
  • [25] Treatment Response of Primary Brain Tumour Treated with 3D Conformal Radiotherapy
    Tun, A. K. P.
    Nu, Y.
    Aung, M. M.
    RADIOTHERAPY AND ONCOLOGY, 2019, 141 : S58 - S58
  • [26] Dosimetric assessment of 3D Radiotherapy and IMRT in Wilms' tumor : benefit-risk balance
    Bouzid, N.
    Zanzouri, R.
    Amri, B.
    Souissi, M.
    Tbessi, S.
    Belaajouza, S.
    Tebra, S.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1770 - S1770
  • [27] Second cancer induction risk from breast radiotherapy with VMAT and 3D conformal therapy
    Fogliata, A.
    De Rose, F.
    Franceschini, D.
    Stravato, A.
    Seppala, J.
    Scorsetti, M.
    Cozzi, L.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S478 - S478
  • [28] Individualized margins in 3D conformal radiotherapy planning for lung cancer: Analysis of physiological movements and their dosimetric impacts
    Germain, Francois
    Beaulieu, Luc
    Fortin, Andre
    MEDICAL DOSIMETRY, 2008, 33 (01) : 48 - 54
  • [29] Comparison of VMAT and 3D conformal radiotherapy treatment planning in patients with "limited disease" small cell Lung cancer
    Prokic, V
    Duncker-Rohr, V
    Offermann, C.
    Amschlinger, A.
    Nestle, U.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 : 153 - 154
  • [30] Conventional 3D conformal versus intensity-modulated radiotherapy for the adjuvant treatment of gynecologic malignancies: a comparative dosimetric study of dose-volume histograms
    Heron, DE
    Gerszten, K
    Selvaraj, RN
    King, GC
    Sonnik, D
    Gallion, H
    Comerci, J
    Edwards, RP
    Wu, A
    Andrade, RS
    Kalnicki, S
    GYNECOLOGIC ONCOLOGY, 2003, 91 (01) : 39 - 45