Conventional 3D conformal versus intensity-modulated radiotherapy for the adjuvant treatment of gynecologic malignancies: a comparative dosimetric study of dose-volume histograms

被引:135
|
作者
Heron, DE [1 ]
Gerszten, K [1 ]
Selvaraj, RN [1 ]
King, GC [1 ]
Sonnik, D [1 ]
Gallion, H [1 ]
Comerci, J [1 ]
Edwards, RP [1 ]
Wu, A [1 ]
Andrade, RS [1 ]
Kalnicki, S [1 ]
机构
[1] Univ Pittsburgh, Sch Med, Inst Canc, Pittsburgh, PA 15260 USA
关键词
D O I
10.1016/S0090-8258(03)00461-X
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objectives. The goals of this study were to evaluate the feasibility of pelvic intensity-modulated radiotherapy (IMRT) in the adjuvant treatment of gynecologic malignancies and to compare the dose-volume histograms (DVHs) and determine the potential impact on acute and long-term toxicity based on the dose to target and nontarget tissues for both planning techniques. Methods. Ten consecutive patients referred for adjuvant radiotherapy for gynecologic malignancies at the University of Pittsburgh School of Medicine and Magee-Womens Hospital were selected for CT-based treatment planning using the ADAC 3D version 4.2g and the NOMOS Corvus IMRT version 4.0. Normal tissues and critical structures were contoured on axial CT slices by both systems in conjunction with a gynecologic radiologist. These regions included internal, external, and common iliac nodal groups, rectum, upper 4 cm of vagina, bladder, and small bowel. Conventional treatment planning included 3D four-field box using 18-MV photons designed to treat a volume from the L-5/S-1 border superiorly to the bottom of the ischial tuberosity on the AP/PA field and shaped blocks on the lateral fields to minimize the dose to the rectum and small bowel. A seven-field technique using 6-MV photons was used for IMRT. Restraints on small bowel for IMRT were set at 23.0 Gy +/- 5% and 35.0 Gy +/- 5% for the rectum and 37.5 Gy +/- 5% for the bladder while simultaneously delivering full dose (45.0 Gy) to the intrapelvic nodal groups in 1.8-Gy daily fractions. The dose-volume histograms where then compared for both treatment delivery systems. Results. The volume of each organ of interest (small bowel, bladder, and rectum) receiving doses in excess of 30 Gy was compared in the 3D and IMRT treatment plans. The mean volume of small bowel receiving doses in excess of 30 Gy was reduced by 52% with IMRT compared with 3D. A similar advantage was noted for the rectum (66% reduction) and the bladder (36% reduction). The nodal regions at risk and the upper vagina all received the prescribed dose of 45.0 Gy. Conclusions. Intensity-modulated radiotherapy appears to offer several advantages over conventional 3D radiotherapy (3D CRT) planning for adjuvant radiotherapy for gynecologic malignancies. These include a significant reduction in treatment volume for bladder, rectum, and small bowel. It is anticipated that this reduction in volume of normal tissue irradiated would translate into overall reduction in acute and potentially late treatment-related toxicity. Prospective trials are necessary to better evaluate the advantages in a larger group of patients. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:39 / 45
页数:7
相关论文
共 50 条
  • [1] CONVENTIONAL 3D CONFORMAL RADIATION (3D-CRT) VERSUS DIFFERENT INTENSITY-MODULATED RADIOTHERAPY (IMRT) TECHNIQUES FOR THE TREATMENT OF VULVAR CANCER: A DOSIMETRIC ANALYSIS OF DOSE-VOLUME HISTOGRAMS
    Bloemers, M.
    Portelance, L.
    Ruo, R.
    Duclos, M.
    Bahoric, B.
    Souhami, L.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S48 - S48
  • [2] Syed-Neblett template interstitial implant versus intensity modulated radiotherapy for the treatment of gynecologic malignancies: A comparative study of dose-volume histograms
    Selvaraj, RN
    Heron, DE
    Gerszten, K
    King, GC
    Wu, A
    Kalnicki, S
    RADIOLOGY, 2002, 225 : 170 - 170
  • [3] Dosimetric comparison of intensity modulated pelvic radiotherapy with 3D conformal radiotherapy in patients with gynecologic malignancies
    Igdem, S.
    Ercan, T.
    Alco, G.
    Zengin, F.
    Ozgules, R.
    Geceer, G.
    Okkan, S.
    Ober, A.
    Turkan, S.
    EUROPEAN JOURNAL OF GYNAECOLOGICAL ONCOLOGY, 2009, 30 (05) : 547 - 551
  • [4] 3D CONFORMAL VERSUS INTENSITY-MODULATED RADIOTHERAPY IN POST PROSTATECTOMY PATIENTS: A DOSIMETRIC COMPARISON
    Martin, Giuseppe
    Totaro, Giuseppe
    Verga, Enrico
    De Chiara, Vincenzo
    Morrone, Paolo
    Cicalese, Anna Rita
    Falco, Maria Daniela
    ANTICANCER RESEARCH, 2011, 31 (05) : 1877 - 1878
  • [5] 3D conformal radiotherapy and intensity-modulated radiotherapy: towards dose optimization
    Almudena Zapatero Laborda
    Revista de Oncología, 2002, 4 (2): : 103 - 108
  • [6] Intensity-Modulated Radiation Therapy Versus 3D Conformal Radiotherapy for Postoperative Gynecologic Cancer: Are They Covering the Same Planning Target Volume?
    Lukovic, Jelena
    Patil, Nikhilesh
    D'souza, David
    Millman, Barbara
    Yaremko, Brian P.
    Leung, Eric
    Whiston, Frances
    Hajdok, George
    Wong, Eugene
    CUREUS, 2016, 8 (01):
  • [7] Comparison of dose-volume histograms for Tomo therapy, linear accelerator-based 3D conformal radiation therapy, and intensity-modulated radiation therapy
    Ji, Youn-Sang
    Dong, Kyung-Rae
    Kim, Chang-Bok
    Choi, Seong-Kwan
    Chung, Woon-Kwan
    Lee, Jong-Woong
    ANNALS OF NUCLEAR ENERGY, 2011, 38 (11) : 2569 - 2574
  • [8] DOSIMETRIC COMPARISON OF VOLUMETRIC INTENSITY-MODULATED ARC (RAPIDARC) THERAPY, INTENSITY-MODULATED RADIOTHERAPY, AND 3D CONFORMAL RADIOTHERAPY FOR PRIMARY LIVER TUMOURS
    John, Jacob
    Sivasevan, Roshni
    Sudha, Arun Sankar
    Sivanandan, Choondal Devan
    Abdurahman, Sajeed
    Paramu, Raghukumar
    Sreedevi, Shaiju Vasudevan
    George, Preethi Sara
    Jayaprakash, Puthuveettil Govindan
    EUROPEAN JOURNAL OF CANCER, 2015, 51 : E34 - E34
  • [9] 3D-CONFORMAL VERSUS INTENSITY-MODULATED POSTOPERATIVE RADIOTHERAPY OF VAGINAL VAULT: A DOSIMETRIC COMPARISON
    Cilla, Savino
    Macchia, Gabriella
    Digesu, Cinzia
    Deodato, Francesco
    Romanella, Michele
    Ferrandina, Gabriella
    Padula, Gilbert D. A.
    Picardi, Vincenzo
    Scambia, Giovanni
    Piermattei, Angelo
    Morganti, Alessio Giuseppe
    MEDICAL DOSIMETRY, 2010, 35 (02) : 135 - 142
  • [10] LARGE COHORT DOSE-VOLUME RESPONSE ANALYSIS OF PAROTID GLAND FUNCTION AFTER RADIOTHERAPY: INTENSITY-MODULATED VERSUS CONVENTIONAL RADIOTHERAPY
    Dijkema, Tim
    Terhaard, Chris H. J.
    Roesink, Judith M.
    Braam, Petra M.
    van Gils, Carla H.
    Moerland, Marinus A.
    Raaijmakers, Cornelis P. J.