Comparison of dose-volume histograms for Tomo therapy, linear accelerator-based 3D conformal radiation therapy, and intensity-modulated radiation therapy

被引:1
|
作者
Ji, Youn-Sang [2 ]
Dong, Kyung-Rae [1 ,2 ]
Kim, Chang-Bok [2 ]
Choi, Seong-Kwan [2 ]
Chung, Woon-Kwan [1 ]
Lee, Jong-Woong [3 ]
机构
[1] Chosun Univ, Dept Nucl Engn, Kwangju 501759, South Korea
[2] Gwangju Hlth Coll Univ, Dept Radiol Technol, Kwangju, South Korea
[3] Kyung Hee Univ Hosp, Dept Radiol, Seoul, South Korea
关键词
3D CRT; IMRT; Tomo; GTV; CTV; TOMOTHERAPY;
D O I
10.1016/j.anucene.2011.07.025
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Evaluation of dose-volume histograms from three-dimensional conformal radiation therapy (3D CRT), intensity-modulated radiation therapy (IMRT), and Tomo therapy was conducted. These three modalities are among the diverse treatment systems available for tumor therapy. Three patients who received tumor therapy for a malignant oligodendroglioma in the cranium. nasopharyngeal carcinoma in the cervical neck, and prostate cancer in the pelvis were selected as study subjects. Therapy plans were made for the three patients before dose-volume histograms were obtained. The doses of the gross tumor volume (GTV) and the clinical target volume (CTV) were compared using the dose-volume histograms obtained from the LINAC-based 3D CRT, IMRT planning station (Varian Eclipse-Varian, version 8.1), and Tomo therapy planning station. In addition, the doses of critical organs in the cranium, cervix, and pelvis that should be protected were compared. The GTV was higher when Tomo therapy was used compared to 3D CRT and the LINAC-based IMRT, while the doses of critical organ tissues that required protection were low. These results demonstrated that Tomo therapy satisfied the ultimate goal of radiation therapy more than the other therapies. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2569 / 2574
页数:6
相关论文
共 50 条
  • [1] Quantitative Analysis of Tomotherapy, Linear-accelerator-based 3D Conformal Radiation Therapy, Intensity-modulated Radiation Therapy, and 4D Conformal Radiation Therapy
    Cho, Jae-Hwan
    Lee, Hae-Kag
    Dong, Kyung-Rae
    Chung, Woon-Kwan
    Lee, Jong-Woong
    Park, Hoon-Hee
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 60 (07) : 1167 - 1176
  • [2] Quantitative analysis of tomotherapy, linear-accelerator-based 3D conformal radiation therapy, intensity-modulated radiation therapy, and 4D conformal radiation therapy
    Jae-Hwan Cho
    Hae-Kag Lee
    Kyung-Rae Dong
    Woon-Kwan Chung
    Jong-Woong Lee
    Hoon-Hee Park
    [J]. Journal of the Korean Physical Society, 2012, 60 : 1167 - 1176
  • [3] Dose-volume specification: New challenges with intensity-modulated radiation therapy
    Purdy, JA
    [J]. SEMINARS IN RADIATION ONCOLOGY, 2002, 12 (03) : 199 - 209
  • [4] Use of benchmark dose-volume histograms for selection of the optimal technique between three-dimensional conformal radiation therapy and intensity-modulated radiation therapy in prostate cancer
    Luo, Chunhui
    Yang, Claus Chunli
    Narayan, Samir
    Stern, Robin L.
    Perks, Julian
    Goldberg, Zelanna
    Ryu, Janice
    Purdy, James A.
    Vijayakumar, Srinivasan
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (04): : 1253 - 1262
  • [5] Predicting Dose-volume Histograms for Organs at Risk in Intensity Modulated Radiation Therapy Planning
    Appenzoller, L.
    Mutic, S.
    Michalski, J. M.
    Thorstad, W. L.
    Moore, K. L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S79 - S80
  • [6] Dose-volume constrained optimization in intensity-modulated radiation therapy treatment planning
    Yoshihiro Tanaka
    Ken’ichi Fujimoto
    Tetsuya Yoshinaga
    [J]. Journal of Inequalities and Applications, 2015
  • [7] Dose-volume constrained optimization in intensity-modulated radiation therapy treatment planning
    Tanaka, Yoshihiro
    Fujimoto, Ken'ichi
    Yoshinaga, Tetsuya
    [J]. JOURNAL OF INEQUALITIES AND APPLICATIONS, 2015, : 1 - 13
  • [8] Comparison of intensity-modulated radiation therapy (IMRT), 3D conformal proton therapy and intensity-modulated proton therapy (IMPT) for the treatment of metastatic brain cancer
    Sullivan, Matthew
    Jin, Hosang
    Ahmad, Salahuddin
    [J]. MEDICAL DOSIMETRY, 2023, 48 (02) : 73 - 76
  • [9] Comparison of Intensity-Modulated Radiation Therapy, Intensity-Modulated Arc Therapy and Arc-Modulated Radiation Therapy
    Tang, G.
    Earl, M.
    Luan, S.
    Wang, C.
    Naqvi, S.
    Yu, C.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [10] Dose-volume Comparison of 3D-conformal Radiation Therapy (3D-CRT) and Intensity Modulated Radiation Therapy (IMRT) for Salvage or Adjuvant Treatment of the Prostatic Bed
    Shapiro, R.
    Zook, J.
    Bartlett, G.
    Hoene, T.
    Das, I.
    Ko, S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S755 - S755