Incorporation of wavelet-based denoising in iterative deconvolution for partial volume correction in whole-body PET imaging

被引:98
|
作者
Boussion, N. [1 ]
Le Rest, C. Cheze [1 ]
Hatt, M. [1 ]
Visvikis, D. [1 ]
机构
[1] CHU MORVAN, INSERM, U650, LaTIM, F-29609 Brest, France
关键词
FDG-PET; Image processing; Partial volume correction; Whole-body PET; MATTER VOLUME; DECOMPOSITION; VALIDATION; ALGORITHMS;
D O I
10.1007/s00259-009-1065-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Partial volume effects (PVEs) are consequences of the limited resolution of emission tomography. The aim of the present study was to compare two new voxel-wise PVE correction algorithms based on deconvolution and wavelet-based denoising. Deconvolution was performed using the Lucy-Richardson and the Van-Cittert algorithms. Both of these methods were tested using simulated and real FDG PET images. Wavelet-based denoising was incorporated into the process in order to eliminate the noise observed in classical deconvolution methods. Both deconvolution approaches led to significant intensity recovery, but the Van-Cittert algorithm provided images of inferior qualitative appearance. Furthermore, this method added massive levels of noise, even with the associated use of wavelet-denoising. On the other hand, the Lucy-Richardson algorithm combined with the same denoising process gave the best compromise between intensity recovery, noise attenuation and qualitative aspect of the images. The appropriate combination of deconvolution and wavelet-based denoising is an efficient method for reducing PVEs in emission tomography.
引用
收藏
页码:1064 / 1075
页数:12
相关论文
共 50 条
  • [41] Quantitative accuracy of MR-based attenuation correction in whole-body PET/MR
    Schramm, Georg
    Langner, Jens
    Hofheinz, Frank
    Baumann, Bettina Beuthien
    Platzek, Ivan
    Kotzerke, Jorg
    Steinbach, Joerg
    van den Hoff, Joerg
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [42] A deep learning-based whole-body solution for PET/MRI attenuation correction
    Sahar Ahangari
    Anders Beck Olin
    Marianne Kinggård Federspiel
    Bjoern Jakoby
    Thomas Lund Andersen
    Adam Espe Hansen
    Barbara Malene Fischer
    Flemming Littrup Andersen
    EJNMMI Physics, 9
  • [43] MR-based Attenuation Correction for a Whole-body Sequential PET/MR System
    Hu, Z.
    Ojha, N.
    Renisch, S.
    Schulz, V.
    Torres, I.
    Buhl, A.
    Pal, D.
    Muswick, G.
    Penatzer, J.
    Guo, T.
    Boenert, P.
    Tung, C.
    Kaste, J.
    Morich, M.
    Havens, T.
    Maniawski, P.
    Schaefer, W.
    Guenther, R. W.
    Krombach, G. A.
    Shao, L.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3508 - 3512
  • [44] Whole-body MR-based attenuation correction for PET using UTE Sequences
    Keereman, V.
    Fierens, Y.
    De Deene, Y.
    Vandenberghe, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S220 - S220
  • [45] Whole-body PET/MRI: The effect of bone attenuation during MR-based attenuation correction in oncology imaging
    Aznar, M. C.
    Sersar, R.
    Saabye, J.
    Ladefoged, C. N.
    Andersen, F. L.
    Rasmussen, J. H.
    Lofgren, J.
    Beyer, T.
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (07) : 1177 - 1183
  • [46] A deep learning-based whole-body solution for PET/MRI attenuation correction
    Ahangari, Sahar
    Olin, Anders Beck
    Federspiel, Marianne Kinggard
    Jakoby, Bjoern
    Andersen, Thomas Lund
    Hansen, Adam Espe
    Fischer, Barbara Malene
    Andersen, Flemming Littrup
    EJNMMI PHYSICS, 2022, 9 (01)
  • [47] CT-based attenuation correction of whole-body radiotherapy treatment positioning devices in PET/MRI hybrid imaging
    Taeubert, Leticia
    Berker, Yannick
    Beuthien-Baumann, Bettina
    Hoffmann, Aswin L.
    Troost, Esther G. C.
    Kachelriess, Marc
    Gillmann, Clarissa
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (23):
  • [48] Deep learninga(sic)'based CT-free attenuation and scatter correction for pediatric whole-body PET imaging
    Han, Chenyang
    Trout, Andrew
    MacLean, Joseph
    Zhu, Jieyuhan
    Tang, Jing
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [49] Validations for MR-based partial volume correction for brain PET imaging
    Matsubara, Keisuke
    Ibaraki, Masanobu
    Maeda, Tetsuya
    Kinoshita, Toshibumi
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [50] Clinical evaluation of processing techniques for attenuation correction with 137Cs in whole-body PET imaging
    Bénard, F
    Smith, RJ
    Hustinx, P
    Karp, JS
    Alavi, A